ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • OPTICS  (9)
  • Chemistry  (5)
  • 65N30  (1)
  • Polymer and Materials Science
  • 2005-2009
  • 1990-1994  (15)
  • 1980-1984
  • 1965-1969
  • 1930-1934
  • 1992  (15)
Collection
Publisher
Years
  • 2005-2009
  • 1990-1994  (15)
  • 1980-1984
  • 1965-1969
  • 1930-1934
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Numerische Mathematik 62 (1992), S. 1-15 
    ISSN: 0945-3245
    Keywords: 65N30
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Notes: Summary A finite element procedure for circumventing the Babuška-Brezzi condition in mixed formulations with Lagrange multipliers defined on the boundary is presented. Residual terms constructed from the Euler-Lagrange equations are added to the classical Galerkin formulation in order to attain coercivity in a mesh-dependent norm. Convergence is proven for the primal variable and the multiplier in the natural mesh-independent norm of the problem, generalizing results of a previous paper.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 16 (1992), S. 119-125 
    ISSN: 0308-0501
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Architecture, Civil Engineering, Surveying , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: This study is based on the use of integral, hybrid thermal barrier to protect the core of the composite structure. Thermal barrier treatments evaluated in this study include ceramic fabric, ceramic coating, intumescent coating, hybrid of ceramic and intumescent coating, silicone foam, and phenolic skin. The composite systems evaluated in combination with thermal barrier treatments included glass/vinyl ester, graphite/epoxy, graphite/bismaleimide, and graphite/phenolic. All configurations were tested for flammability characteristics. These included smoke density and combustion gas generation (ASTM E-662), residual flexural strength (ASTM D-790), heat release rate, and ignitability (ASTM E-1354). ASTM E-662 test method covers the determination of specific optical density of smoke generated by solid materials. ASTM D-790 test method covers the determination of flexural properties of composite materials in the form of rectangular bars. ASTM E-1354 (cone calorimeter) covers the measurement of the response of materials exposed to controlled levels of radiant heating with or without an external ignitor, and is used to determine the ignitability, heat release rates, mass loss rates, effective heat of combustion, and visible smoke development. Without any fire barrier treatments, all composite systems evaluated in this study failed to meet ignitability and peak heat release requirements of MIL-STD-2031 (SH) at radiant heat fluxes of 75 and 100 kW m-2, respectively. Intumescent coating and a hybrid system consisting of intumescent coating over ceramic coating were the most effective fire barrier treatments for composite systems evaluated in this study. Using either of these treatments, all composite systems met the ignitability requirements of 90 and 60 at 75 and 100 kW m-2, respectively. Except for glass/vinyl ester, all systems also met the peak and average heat release requirements of MIL-STD-2031 (SH) at radiant heat fluxes of 25, 75, and 100 kW m-2, respectively.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: N-Terminal sequence analysis of proteins separated by two-dimensional polyacrylamide gel electrophoresis and transferred onto polyvinylidene difluoride (PVDF) membranes has become the method for molecular characterization of proteins contained in biological samples. However, the proteins of lower abundance cannot be sequenced directly, without improving the technique. We have studied a drying method on several PVDF membranes including Trans-Blott, Immobilon P and Problott. Using Amido Black, Coomassie Brilliant Blue R-250 and Ponceau S, we have obtained, in comparison with the non-dried membranes, an enormous increase in the number of detectable proteins.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: This publication establishes a reference human liver protein map obtained with immobilized pH gradients. By microsequencing, 57 spots or 42 polypeptide chains were identified. By protein map comparison and matching (liver, red blood cell and plasma sample maps), 8 additional proteins were identified. The new polypeptides and previously known proteins are listed in a table and/or labeled on the protein map, thus providing a human liver two-dimensional gel database. This reference map can be used to identify protein spots on other samples such as rectal cancer biopsies.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Normal human skin fibroblast primary cell lines secrete over 50 proteins into culture medium. These have been mapped previously using two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and this technique has now been used to investigate extracellular protein secretion by human osteoblasts in vitro. We report the mapping of a number of consistent markers specific to the osteoblast. In particular, one protein chain with posttranslational modifications was found to be unique to the osteoblast extracellular protein map. The absence of the N- and O-glycoforms of collagenase from the osteoblast profile in this study concurs with findings reported using the immunoprecipitation functional assay and Northern blot analysis. The use of 2-D PAGE in phenotypic assessment provides a more complete analysis than the standard range of single-parameter tests for osteobiasts. Mapping of extracellular and cellular proteins in addition to bone matrix protein analysis will allow a comprehensive analysis of normal osteoblast function. This technique may also be applied to the study of osteoblasts in relation to bone disease and in assessing the phenotypic shift within a normal osteoblast culture.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0173-0835
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: The reference plasma protein map, obtained with immobilized pH gradients in the first dimension of two-dimensional electrophoresis, is presented. By microsequencing, more than 40 polypeptide chains were identified. The new polypeptides and previously known proteins are listed in a table and labeled on the protein map, thus providing an update of the human plasma two-dimensional gel database.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2013-08-31
    Description: The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2013-08-31
    Description: We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are one dimensional scans of the core of the point response function (PRF) (full width half maximum (FWHM) scans), the encircled energy as a function of radius, and one dimensional scans of the wings of the PRF. We discuss briefly our ray trace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1 mm(exp -1). Constraints on the average amplitude of circumferential slope errors are derived as well.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2013-08-31
    Description: The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 8 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2013-08-31
    Description: The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.
    Keywords: OPTICS
    Type: VETA-I X Ray Test Analysis; 16 p
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...