ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Weitere Quellen  (29)
  • 2010-2014
  • 2000-2004
  • 1995-1999
  • 1990-1994  (29)
  • 1965-1969
  • 1960-1964
  • 1992  (29)
Sammlung
Datenquelle
Erscheinungszeitraum
  • 2010-2014
  • 2000-2004
  • 1995-1999
  • 1990-1994  (29)
  • 1965-1969
  • +
Jahr
  • 1
    Publikationsdatum: 2011-08-24
    Beschreibung: We have investigated the direct effect of dimethyl prostaglandin A1 (dmPGA1) on the replication of herpes simplex virus (HSV) and human immunodeficiency virus type 1 (HIV-1). dmPGA1 significantly inhibited viral replication in both HSV and HIV infection systems at concentrations of dmPGA1 that did not adversely alter cellular DNA synthesis. The 50% inhibitory concentration (ID50) for several HSV type 1 (HSV-1) strains ranged from 3.8 to 5.6 micrograms/ml for Vero cells and from 4.6 to 7.3 micrograms/ml for human foreskin fibroblasts. The ID50s for two HSV-2 strains varied from 3.8 to 4.5 micrograms/ml for Vero cells; the ID50 was 5.7 micrograms/ml for human foreskin fibroblasts. We found that closely related prostaglandins did not have the same effect on the replication of HSV; dmPGE2 and dmPGA2 caused up to a 60% increase in HSV replication compared with that in untreated virus-infected cells. HIV-1 replication in acutely infected T cells (VB line) and chronically infected macrophages was assessed by quantitative decreases in p24 concentration. The effective ID50s were 2.5 micrograms/ml for VB cells acutely infected with HIV-1 and 5.2 micrograms/m for chronically infected macrophages. dmPGA1 has an unusual broad-spectrum antiviral activity against both HSV and HIV-1 in vitro and offers a new class of potential therapeutic agents for in vivo use.
    Schlagwort(e): Life Sciences (General)
    Materialart: Antimicrobial agents and chemotherapy (ISSN 0066-4804); Volume 36; 10; 2253-8
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Publikationsdatum: 2011-08-24
    Beschreibung: Ground magnetic field perturbations recorded by the CANOPUS magnetometer network in the 7 to 13 MLT sector are used to examine how reconfigurations of the dayside polar ionospheric flow take place in response to north-south changes of the IMF. During the 6-h interval in question, IMF Bz oscillates between +/- 7 nT with about a 1-h period. Corresponding variations in the ground magnetic disturbance are observed which we infer are due to changes in ionospheric flow. Cross correlation of the data obtained from two ground stations at 73.5 deg magnetic latitude, but separated by about 2 hours in MLT, shows that changes in the flow are initiated in the prenoon sector (about 10 MLT) and then spread outward toward dawn and dusk with a phase speed of about 5 km/s over the longitude range about 8 to 12 MLT, slowing to about 2 km/s outside this range. Cross correlating the data from these ground stations with IMP 8 IMF Bz records produces a MLT variation in the ground response delay relative to the IMF which is compatible with these deduced phase speeds.
    Schlagwort(e): GEOPHYSICS
    Materialart: Journal of Geophysical Research (ISSN 0148-0227); 97; A12; p. 19,373-19,380.
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Publikationsdatum: 2011-08-24
    Beschreibung: Output of 1.25 J per pulse (1.064 micron) with an absolute optical efficiency of 28 percent and corresponding electrical efficiency of 10 percent was demonstrated in a diode-array-pumped Nd:YAG laser using a side-pumped rod geometry in a master-oscillator/power-amplifier configuration. In Q-switched operation, an output of 0.75 J in a 17-ns pulse was obtained. The fundamental laser output was frequency doubled in KTP with 60 percent conversion efficiency to obtain 0.45 J in a 16-ns pulse at 532 nm. The output beam had high spatial quality with pointing stability better than 40 microrad and a shot-to-shot pulse energy fluctuation of less than +/-3 percent.
    Schlagwort(e): LASERS AND MASERS
    Materialart: IEEE Journal of Quantum Electronics (ISSN 0018-9197); 28; 4, Ap; 977-985
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2013-08-31
    Beschreibung: The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Publikationsdatum: 2013-08-31
    Beschreibung: We employ the X-ray measurements of the VETA-I taken at the X-Ray Calibration Facility (XRCF) of the Marshall Space Flight Center (MSFC) to extract information about the surface finish quality of the outermost pair of AXAF mirrors. The particular measurements we consider are one dimensional scans of the core of the point response function (PRF) (full width half maximum (FWHM) scans), the encircled energy as a function of radius, and one dimensional scans of the wings of the PRF. We discuss briefly our ray trace model which incorporates the numerous effects present in the VETA-I test, such as the finite source distance, the size and shape of the X-ray source, the residual gravitational distortions of the optic, the despace of the VETA-I, and particulate contamination. We show how the data constrain the amplitude of mirror surface deviations for spatial frequencies greater than about 0.1 mm(exp -1). Constraints on the average amplitude of circumferential slope errors are derived as well.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 10 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Publikationsdatum: 2013-08-31
    Beschreibung: The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 8 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Publikationsdatum: 2013-08-31
    Beschreibung: The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 16 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Publikationsdatum: 2013-08-31
    Beschreibung: Initial core scan data of the VETA-I x-ray mirror proved disappointing, showing considerable unpredicted image structure and poor measured FWHM. 2-D core scans were performed, providing important insight into the nature of the distortion. Image deconvolutions using a ray traced model PSF was performed successfully to reinforce our conclusion regarding the origin of the astigmatism. A mechanical correction was made to the optical structure, and the mirror was tested successfully (FWHM 0.22 arcsec) as a result.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 16 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Publikationsdatum: 2013-08-31
    Beschreibung: Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.
    Schlagwort(e): OPTICS
    Materialart: VETA-I X Ray Test Analysis; 20 p
    Format: application/pdf
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Publikationsdatum: 2013-08-29
    Beschreibung: The objective of this presentation is to identify potential plume heating/impingement problem areas on vehicles used for future lunar missions. This is accomplished by comparison with lunar module plume investigations performed during 1968-1971. All material is presented in viewgraph format.
    Schlagwort(e): MECHANICAL ENGINEERING
    Materialart: Third SEI Technical Interchange: Proceedings; p 597-611
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...