ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Biochemistry and Biotechnology  (49)
  • Column liquid chromatography  (16)
  • Wiley-Blackwell  (49)
  • Springer  (16)
  • Springer Nature
  • 1990-1994  (65)
  • 1991  (65)
Collection
Publisher
  • Wiley-Blackwell  (49)
  • Springer  (16)
  • Springer Nature
Years
  • 1990-1994  (65)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 38 (1991), S. 557-560 
    ISSN: 0006-3592
    Keywords: levan ; continuous culture ; molecular weight ; Erwinia herbicola ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The optimal production of the fructan biopolymer levan by the bacterium Erwinia herbicola was investigated, including variations in nitrogen, carbon and phosphorous sources, pH, incubation time, culture yields up to 19% by weight produced based on conversion of sucrose as the carbon source when grown in a continuous culture system and processed by tangential flow filtration. Product identity was confirmed with gas chromatography (GC) and 13C nuclear magnetic resonance (NMR). Gel permeation chromatography (GPC) and low-angle laser light scattering (LALLS) determination of the molecular weight of the product showed a significant difference in molecular weight values dependent on the method of analysis. Analysis by GPC resulted in molecular weight one order of magnitude lower than LALLS independent of sample, underscoring the unusual nature of this biopolymer.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 31 (1991), S. 362-366 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Particle size distribution ; Stationary phase stress ; Silica gel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A particle size distribution analysis has been completed on three different HPLC column packing materials including silica gel (Si60) and two bonded phases (RP8 and RP18). The stationary phases were subjected to 18 hours stress with 1 N or 3 N KOH and found to have quantitatively different distribution patterns initially, at 13 hours and finally at 18 hours although the average particle diameters for the Si60 and RP8 were the same or higher at 18 hours as initially. Thirteen hoursstress with sodium octanesulfonate, tetrabutylammonium phosphate and ammonium acetate at exaggerated conditions also resulted in distributional changes with the Si60 and RP8 decreasing in average particle diameter when exposed to ammonium acetate and tetrabutylammonium stressing respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Furfural ; Hydroxymethylfurfural ; Apple juice
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid and sensitive method for determining 2-furaldehyde (FUR) and 5-hydroxymethyl-2-furaldehyde (HMF) in apple juices and juice concentrates has been developed. The method for FUR and HMF involves the solid-liquid extraction of the juice by using a C-18 cartridge prior to reversed-phase separation with detection at 280 nm. The mobile phase was acetonitrile-water (8/92, v/v) at a flow rate of 1.0 ml/min. Recoveries from apple juices and juice concentrates spiked at different levels ranged from 94.1 to 104.0 (FUR) and 94.5 to 100.5 (HMF). The quantification limit for both, FUR and HMF, was 5 ppb.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 38 (1991), S. 733-741 
    ISSN: 0006-3592
    Keywords: hybridoma metabolism ; suspension culture ; antibody production rate ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The steady-state metabolic parameters for a murine hybridoma cell line have been determined in continuous suspension culture over a wide range of dilution rates. Long-term adaption occurred over seven months in culture and resulted in lower glucose consumption rates, reduced lactate production, higher cell viability, and, consequently, growth rates more nearly matching the dilution rate. Antibody production rates decreased over the first two months and then remained stable for at least 75 days. The antibody production rate was not found to be growth associated. Steadystate amino acid uptake rates are presented for a wide range of growth rates.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Size exclusion chromatography ; Styrene-methacrylate polymers ; IR and UV spectroscopy ; Lubricating oils additives
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Characterization of a poly(styrene-alkyl methacrylate) viscosity index improver according to its chemical composition distribution and molecular weight distribution was carried out by liquid adsorption chromatography, size exclusion chromatography and infrared and ultraviolet spectrophotometry. The industrial polymer was fractionated by liquid chromatography using silica gel as adsorbent and a mixture of 1,2-dichloroethane and methanol as mobile phase. Each fraction was analyzed by size exclusion chromatography and infrared and ultraviolet spectroscopy. The number average molecular weight ranged from 10000 to 36000 and the weight average molecular weight from 19000 to 264000. The styrene content of the various fractions analysed was between 29.5% and 72.2%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Cyclodextrin inclusion complexes ; Structure-retention relationships ; Polycyclic aromatics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention behaviour of a group of polycyclic aromatic hydrocarbons having nearly equal ionization potentials but different molecular polarizability values was investigated by reversed-phase HPLC and gas chromatography, using β-cyclodextrin as a selective inclusion reagent. In HPLC, the cyclodextrin was applied as an additive to the ethanolwater binary mobile phase, while in gas chromatography β-cyclodextrin served as the stationary phase coated on an inert support. The relationships between the capacity factors, molecular polarizabilities and the shape parameter of solute molecules is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ion exchange chromatography ; Quantitative amino acid analysis ; OPA/FMOC precolumn derivatization ; Cheese
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An improved HPLC method for the quantitative determination of the amino acids from hydrolysed cheese proteins and peptides is described. Some important improvements to the existing method are suggested. The addition of piperidine-4-carboxylic acid (PICA) as a hydrolysis-resistant internal standard enabled the quantification of secondary amino acids. The following analytical parameters have been determined: repeatability, detection limit and linearity in the measuring range. A statistical comparison with the classical ion chromatographic method gave an excellent correlation for all determined amino acids. Both methods are free of artifacts and systematic errors. Compared with ion chromatography, HPLC shows the following advantages: faster equilibration of the column, shorter retention times, more stable baseline, narrower peaks and more sensitive fluorescence detection. A drawback is the slightly lower repeatability for some amino acids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Selenonium and arsonium cations ; AAS detection ; Chromatographic optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Optimal mobile phase compositions were determined for the separation of selenonium ions [trimethylselenonium, (2-hydroxyethyl)dimethylselenonium and (2-acetoxyethyl)dimethylselenonium] and, separately, for arsonium ions (tetramethylarsonium, arsenobetaine, and arsenocholine) by HPLC with detection by atomic absorption spectrometry (AAS). Surface response methodologies were used to predict the variations in detector response (peak area), capacity factors, and selectivities as a function of the mobile phase composition. For selenonium analytes, a mixture of triethylammonium and trimethylsulfonium ions in the methanol-1% acetic acid mobile phase provided a compromise between resolving power and chromatographic efficiency. By contrast, optimum chromatography of the arsonium analytes was obtained by replacing onium additives in the mobile phase by picrylsulfonic acid. For both selenonium and arsonium analytes, the dominant interaction with the stationary phase was with residual silanols and improvements to the chromatographic performance of these analytes resulted in appreciable decreases in their limits of detection.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Size-exclusion ; Peptides ; Casein hydrolysate ; FAB-MS
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A casein hydrolysate was eluted on a TSK G-2000 SW sizeexclusion high-performance liquid chromatography (SE-HPLC) column using a mobile phase which gives a correlation coefficient of 0.98 for the separation of 20 pure and synthetic peptides and proteins of molecular weight (M. W.) varying from 243.28 (Ala-Pro-Gly) to 43 000 (Ovalbumine) daltons. Further isolation and purification of peptides present in each of the 8 different fractions collected from the SE-HPLC were done by reversed-phase HPLC (RP-HPLC). Peptide experimental M. W. determined from the calibration curve obtained for synthetic or purified peptides was compared to their precise M.W. obtained by fast atom bombardment-mass spectrometry analysis (FAB-MS). The results do not show a separation of this complex hydrolysate by SE-HPLC according to the hydrodynamic volume of its constituents.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Ruthenium mixed complexes ; Sulfoxides ; N-Heterocyclic bases ; Hydrophobic properties of aromatic ligand
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The elution behaviour of a series of dichlorobis-(dimethylsulfoxide)bis(N-heterocyclic)ruthenium(II) complexes has been investigated using reversed-phase HPLC. Similar trends as those displayed by the free N-heterocyclic bases have been observed for the complexes, essentially reflecting the hydrophobic properties of the aromatic ligands.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...