ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • ASTROPHYSICS
  • Astrophysics
  • Polymer and Materials Science
  • 1990-1994  (1)
  • 1980-1984
  • 1990  (1)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1990-1994  (1)
  • 1980-1984
Jahr
  • 1
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 24 (1990), S. 79-94 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: An accelerated anodic corrosion method was used to study the effects of heat treatment and bead size on corrosion and metal ion release of porous coated F75 cylinders in saline and serum. Three heat treatments were used: a standard process for F75 implants (HTA), the standard plus an additional hour in air to produce a thin oxide film (HTA′), and a sintering in high vacuum to produce a chromium-depleted surface (HTB). Three bead sizes of similar composition were used, with approximate sizes of 215, 300, and 560 μm. The results demonstrated that HTA′ had the lowest corrosion rate and that of HTB was significantly greater than either HTA or HTA′. The corrosion rates of HTA and HTA′ were significantly greater in serum as compared with saline, whereas that of HTB was not affected by the presence of serum, suggesting an interaction between chromium and serum proteins. Bead size had a minimal effect on the corrosion rate of HTA′. For HTA, the small beads had the highest corrosion rate; the lowest was with the medium-sized beads. Bead size had the most significant effect with HTB, with that of the smaller beads having the higher corrosion rates. The effects of bead size were less consistent in serum, suggesting that protein adsorption may mask some of the surface area effects. It is concluded that the oxide film does reduce corrosion, that proteins do have an influence on the corrosion of F75, and that this method can be a suseful tool for studying the effects of improved heat treatment methods on the corrosion rate of F75 implants.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...