ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (30)
  • Chemistry  (22)
  • Cricetinae  (8)
  • Biochemistry and Biotechnology
  • 1985-1989
  • 1980-1984  (30)
  • 1970-1974
  • 1984  (30)
  • Technology  (19)
  • Natural Sciences in General  (11)
Collection
  • Articles  (30)
Keywords
Years
  • 1985-1989
  • 1980-1984  (30)
  • 1970-1974
Year
  • 1
    facet.materialart.
    Unknown
    American Association for the Advancement of Science (AAAS)
    Publication Date: 1984-09-21
    Description: The development of most regions of the vertebrate nervous system includes a distinct phase of neuronal degeneration during which a substantial proportion of the neurons initially generated die. This degeneration primarily adjusts the magnitude of each neuronal population to the size or functional needs of its projection field, but in the process it seems also to eliminate many neurons whose axons have grown to either the wrong target or an inappropriate region within the target area. In addition, many connections that are initially formed are later eliminated without the death of the parent cell. In most cases such process elimination results in the removal of terminal axonal branches and hence serves as a mechanism to "fine-tune" neuronal wiring. However, there are now also several examples of the large-scale elimination of early-formed pathways as a result of the selective degeneration of long axon collaterals. Thus, far from being relatively minor aspects of neural development, these regressive phenomena are now recognized as playing a major role in determining the form of the mature nervous system.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Cowan, W M -- Fawcett, J W -- O'Leary, D D -- Stanfield, B B -- EY-03653/EY/NEI NIH HHS/ -- NS-18506/NS/NINDS NIH HHS/ -- New York, N.Y. -- Science. 1984 Sep 21;225(4668):1258-65.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/6474175" target="_blank"〉PubMed〈/a〉
    Keywords: Aging ; Animals ; Brain/*growth & development ; Cricetinae ; *Nerve Degeneration ; Nerve Growth Factors/pharmacology ; Nervous System/*growth & development ; Purkinje Cells/physiology ; Rats ; Retina/growth & development ; Superior Colliculi/growth & development ; Synapses/physiology ; Visual Pathways/growth & development
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1984-03-23
    Description: Interferon-beta 1 (IFN-beta 1) complementary DNA was used as a hybridization probe to isolate human genomic DNA clones lambda B3 and lambda B4 from a human genomic DNA library. Blot-hybridization procedures and partial nucleotide sequencing revealed that lambda B3 is related to IFN-beta 1 (and more distantly to IFN-alpha 1). Analyses of DNA obtained from a panel of human-rodent somatic cell hybrids that were probed with DNA derived from lambda B3 showed that lambda B3 is on human chromosome 2. Similar experiments indicated that lambda B4 is not on human chromosomes 2, 5, or 9. The finding that DNA related to the IFN-beta 1 gene (and IFN-alpha 1 gene) is dispersed in the human genome raises new questions about the origins of the interferon genes.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Sagar, A D -- Sehgal, P B -- May, L T -- Inouye, M -- Slate, D L -- Shulman, L -- Ruddle, F H -- AI-16262/AI/NIAID NIH HHS/ -- New York, N.Y. -- Science. 1984 Mar 23;223(4642):1312-5.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/6546621" target="_blank"〉PubMed〈/a〉
    Keywords: Animals ; Base Sequence ; Chromosome Mapping ; Chromosomes, Human/*analysis ; Chromosomes, Human, 1-3 ; Chromosomes, Human, 4-5 ; Chromosomes, Human, 6-12 and X ; Cloning, Molecular ; Cricetinae ; DNA/*analysis ; *Genes ; Humans ; Hybrid Cells ; Interferon Type I/*genetics ; Mice ; Nucleic Acid Hybridization
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 413-425 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A complete study of the static and dynamic strength of complete maxillary dentures was undertaken. First, the denture base material was investigated in its various forms from the point of view of tension, creep, relaxation, fatigue, and the effect of a corrosive environment. Complete dentures were tested under static compression, and the distribution of stresses along the midline of the upper dentures was determined by means of strain rosettes and by reciprocating compression, the determination of their fatigue strength. The results were found to conform with experience as far as lifetime of complete dentures is concerned.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Although dogs have been used widely to study the healing of large caliber synthetic grafts, hypercoagulability probably makes the dog a poor model for studies of small caliber vascular prostheses. The baboon's coagulation system is similar to man's, but large caliber baboon grafts were reported to endothelialize rapidly. In this study the healing pattern of 4mm internal diameter Dacron carotid interpositon grafts in baboons was determined using specimens harvested at time points between 2 weeks and 18 months post-implantation and examined with light and scanning electron microscopy. The luminal surface of baboon grafts in the acute healing phase (〈1 month) was comparable to that reported in the literature for dogs. Baboon grafts did not completely endothelialize until 10-12 weeks post-implantation. For work with small caliber vascular protheses, the dog appears to have no advantage over the baboon as an animal model on the basis of graft healing.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 601-607 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was undertaken to examine the effectiveness of a commercially available n-butyl-2-cyanoacrylate (Histoacryl blueTri-Hawk International, 1570 Barré, Montréal, H4L 4M6 Quebec.) as a local treatment for cutaneous ulcers. Two ulcers, approximately 0.5 cm2 each, were made on the backs of 30 hamsters. The right side was covered with a thin film of tissue adhesive, while the left side was left untreated as a control. Animals were sacrificed at various times post-operatively, the tissue excised, processed, and examined with the light microscope. Results showed that cyanoacrylate decreased the inflammatory exudate early in the experiment, and epithelial migration occurred slightly earlier in experimental tissue. Scab formation was absent in experimental sites until the layer of adhesive was lost. After 2 days, healing was comparable in both experimental and control, and the sites were indistinguishable histologically at day 5.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 895-909 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An alternative to the usual technique of preclotting porous textile vascular prostheses prior to surgical implantation is to render them impermeable to blood by impregnation with a cross-linked albumin filler matrix. This material subsequently becomes the foundation for cellular development. The compatibility of such impregnated fabrics with newly formed endothelial cells has been evaluated by an in vitro organotypic culture method. This technique enables the characterization and numeration of cells that develop on blood contact surfaces and enables determination of their rate of development. Woven, knitted, and velour fabrics were evaluated folllowing coating with albumin and either storage in Tyrode solution or 40% ethanol or desiccation by critical point drying. Preclotted cardiovascular repair fabrics prepared according to conventional surgical protocol served as controls. The identification of the newly formed cells was confirmed histologically. The most extensive and rapid cellular development was observed on the woven fabric and is believed may have resulted from the smoother surface topography of this substrate. Good cellular development was noted particularly on fabrics which had been stored in Tyrode solution. Ethanol had a deleterious effect on the apparent compatibility.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 771-779 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Few in vitro systems for testing dental restorative materials have taken into account the protection afforded by the residual dentine in vivo. In turn opinions differ as to whether an increase in residual dentine thickness increases this protection. In this study an increase in the depth of dentine powder beneath zinc oxide eugenol (ZOE) reduced its toxicity, while this was not the case with the glass ionomer cement. Compaction of the powder had no effect, suggesting that protection was due to binding of the toxicant to the dentine rather than it acting as a physical barrier. Protein was shown to be very important in moderating the cytotoxicity of ZOE. These results suggest that in vivo the irritancy of some materials may be related to the depth of residual dentine but not others. The effect of exposure period and volume of these materials on their cytotoxicity was also investigated. Increasing the volume of ZOE while retaining the same surface area increased the toxicity of ZOE, while with the glass ionomer it had no effect.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In an attempt to find an alternative procedure to the preclotting of porous textile vascular prostheses, the feasibility of an albumin coating and ethanol preservation technique has been evaluated by implanting albuminated polyester prostheses as substitutes in the thoracic aorta of dogs. Nine different grafts representing woven, knitted, and velour constructions were implanted for periods ranging from 4 h to 6 months. At the sacrifice, the grafts were excized for measurement of the thrombogenicity of the flow surface, for pathological examination by light microscopy and SEM, and for quantifying the changes in the textile structure during implantation. Also the kidneys were removed and examined for infarcts caused by trapped circulating emboli. The healing characteristics of the nine different grafts proved similar and followed the same sequence of events as preclotted control grafts. The albumin coating and ethanol preservation resulted in a somewhat slower rate of healing. Yet, given sufficient time, a more completely healed graft was achieved as evidenced by the presence of endothelial-like cells throughout the length of the graft. In addition, the albumin is believed to reinforce the textile structure by reducing the tendency to stretch and dilate in vivo.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 47-60 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An investigation of the tissue reaction to five porous titanium alloy pacemaker electrode tips inserted in sheep hearts was made. Attachment of the electrode tips to the endocardial wall was facilitated by fibrous tissue ingrowth into the porous material. Vascularized fibrocollagenous tissue was found within the pores of the tips. One tip was found to be infected. The presence of occasional multinucleated foreign-body giant cells within the porosity was related to the particulate features of the porous tip. The electrode tips had a reduced sensing impedance compared with conventional solid platinum tips. The present findings are consistent with previous observations relating to porous cobalt-chromium alloy and porous platinum-iridium alloy tips and suggest that porous titanium alloy may be a suitable pacemaker electrode tip material.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 207-224 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The objective of this investigation was to assess the magnitude of the true wear of the polyethylene components of several total knee replacements. Five different prostheses were tested by total joint simulation for the equivalent of 1 month of use. The true wear rates of the tibial components were measured by quantitative recovery of the polyethylene debris. After testing, the tibial components were examined in the scanning electron microscope, and the molecular weight distributions were analyzed. The wear rates were found to range from 0.3 to 1.8 mg per month. The soluble fraction molecular weights ranged from 179,000 to 393,000 with 53-78% soluble. The wear rates, significantly larger than those observed for total hip prostheses, are dominated by the high contact stresses in these prostheses. The wear results in dimensional changes, which are of the same order of magnitude as those due to creep. The debris had two components: fine fibrous particles, found in all cases, and coarse granules, found when the wear rate is relatively high. Evidence for fatigue cracking was found at the surfaces of the tibial component with the highest wear rate. This behavior is consistent with other investigations of the material itself and indicates that continuous deterioration of the polyethylene should be expected in this class of prosthesis.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...