ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chemical Engineering  (165)
  • INSTRUMENTATION AND PHOTOGRAPHY  (149)
  • 1985-1989  (170)
  • 1980-1984  (144)
  • 1985  (170)
  • 1984  (144)
Collection
Publisher
Years
  • 1985-1989  (170)
  • 1980-1984  (144)
Year
  • 1
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 25 (1985), S. 305-310 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Laminar mixing in a single screw extruder between two miscible liquids is considered. Studies are presented which examine the mixing performance in single screw extruders with mixing sections, variable geometry screws, and multi-viscosity mixtures. Model extruders, set up on engine lathes, were used to mix colored silicone rubber which eventually cured in the screw channel. The cured silicone was then removed and sliced to measure the mixing. Results show mixing as a function of both down channel location and total average strain. For the mixing section study, results support the theory of interfacial area reorientation as the key mechanism in mixing section performance. Increasing viscosity ratio for the multi-viscosity study showed a decrease in mixing rate.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: Results from an intercomparison of techniques to measure tropospheric levels of nitric oxide (NO) are discussed. The intercomparison was part of the National Aeronautics and Space Administration's Global Tropospheric Experiment and was conducted at Wallops Island, VA, in July 1983. Instruments intercompared included a laser-induced fluorescence system and two chemiluminescence instruments. The intercomparisons were performed with ambient air at NO mixing ratios ranging from 10 to 60 pptv and NO-enriched ambient air at mixing ratios from 20 to 170 pptv. All instruments sampled from a common manifold. The techniques exhibited a high degree of correlation among themselves and with changes in the NO mixing ratio. Agreement among the three techniques was placed at approximately + or - 30 percent. Within this level of agreement, no artifacts or species interferences were identified.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 90; 12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-28
    Description: The use of a plasma device, the Advanced Concepts Torus-I, for producing atoms and molecules to study spacecraft glow mechanisms is discussed. A biased metal plate, located in the plasma edge, is used to accelerate and neutralize plasma ions, thus generating a neutral beam with a flux approx. 5 x 10 to the 14th power/sq cm/sec at the end of a drift tube. Our initial experiments are to produce a 10 eV molecular and atomic nitrogen beam directed onto material targets. Photon emission in the spectral range 2000 to 9000 A from excited species formed on the target surface will be investigated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center 2d Workshop on Spacecraft Glow; p 202-211
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-12
    Description: A number of techniques have been proposed for detecting atmospheric OH radicals. Of these, the laser-induced fluorescence (LIF) technique has been used by the largest number of investigators. One of the problems arising in connection with the implementation of this technique is related to the perturbing effect of the UV (lambda approximately 282 nm) laser beam used for OH monitoring, while another problem relates to signal extraction. Several new LIF approaches have been or are currently under development with the objective to bring both problems under control. The present paper deals with the experimental features of one of these new approaches. The considered approach is referred to as 2-lambda laser-induced fluorescence (2-lambda LIF). It is shown that the 2-lambda LIF system provides significant advantages over earlier 1-lambda LIF OH measurement instruments operating at ambient pressure.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 90; 12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-12
    Description: This paper reports on a new two-photon laser-induced fluorescence (TP-LIF) sensor capable of making routine measurements at the few parts per trillion volume level. This direct spectroscopic detection method has been demonstrated to be a reliable instrument while performing both on the ground and in the air. As currently designed it is unique in being 'signal' rather than 'signal-to-noise' limited. The latter characteristic enables the TP-LIF sensor to make atmospheric measurements of NO under environmental conditions that might normally be considered unsuitable for a laser technique. These include clouds, rain, and, in general, high-atmospheric-aerosol loading conditions. Of special interest is the insensitivity of the TP-LIF NO instrument to changes in pressure while operating in the troposphere. This characteristic has enabled this sensor to be used to record real-time altitude profiles of NO. Future improvements should make possible two measurement opportunities: (1) NO flux measurements via the airborne eddy-correlation method and (2) nitrogen isotopic distribution measurements (e.g., (N-15)(0-16) versus (N-14)(0-16) as a means of identifying specific NO(x) sources.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 90; 12
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 1329-1337 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Adsorption of organics inot activated carbon particles within a fixed-bed adsorber is modeled using the concept of mixing cells. The adsorption isotherm of these organics is taken to be rectangular because of the commonly observed strong affinity of organics into activated carbons. The model equations are solved by a singular perturbation method, and this results in a graphical procedure similar to that of McCabe and Thiele used in distillation column design. Such a graphical procedure provides a quick means to determine the adsorbate profiles along the adsorber for a given time and also the breakthrough curve, which reflects the performance of the adsorber.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 957-964 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Six char samples generated from two coals were impregnated by solutions with different concentrations of Na2CO3 and /or K2CO3. The catalyst solution penetration was studied, the catalyst uptake was measured, and the effects of impregnation on the char pore structure were determined experimentally. The results indicate that the impregnated catalysts reside only on particle exteriors without significant penetration. The overall rate of reaction is therfore the combination of catalytic reaction on particle exteriors and noncatalytic reaction on the pore surfaces inside the particle. A kinetic model is presented that takes these findings into account.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 965-972 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Oxidation rates of Na2CO3- and K2CO3-impregnated char samples were measured in an isothermal kinetic control regime. The results were analyzed by a previously developed model to extract the intrinsic catalytic reactivities, freed from superimposed noncatalytic and structural effects. Although the overall catalyzed rates are only several times greater than their uncatalyzed counterparts, the intrinsic catalytic rates were found to be four orders of magnitude greater. The results further indicate that the function of the catalyst is to increase the number of active sites without affecting the activation energy. The overall reaction kinetics are demonstrated to contain the combined contributions of both catalytic and noncatalytic reactions, and in this context the effects of multiple catalysts as well as of the pore structure development during reaction can be understood and interpreted.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...