ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Physics  (79)
  • INSTRUMENTATION AND PHOTOGRAPHY  (60)
  • 1980-1984  (139)
  • 1965-1969
  • 1960-1964
  • 1930-1934
  • 1983  (139)
Collection
Publisher
Years
  • 1980-1984  (139)
  • 1965-1969
  • 1960-1964
  • 1930-1934
Year
  • 1
    Publication Date: 2019-07-27
    Description: The employment of area focal plane arrays (FPA) has made it possible to obtain second generation infrared imaging systems with high resolution and sensitivity. The Short Wavelength Infrared (SWIR) region (1-2.5 microns) is of importance for imaging objects at high temperature and under conditions of reflected sunlight. The present investigation is concerned with electrooptical characterization results for 32 x 32 SWIR detector arrays and FPAs which are suitable for use in a prototype imaging spectrometer. The employed detector material is Hg(1-x)Cd(x)Te grown by liquid phase epitaxy on a CdTe transparent substrate. Attention is given to details of processing, the design of the detector array, the multiplexer, the fabrication of the hybrid FPA, and aspects of performance.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Technical issues in infrared detectors and arrays; April 5, 6, 1983; Arlington, VA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 21 (1983), S. 3033-3033 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 21 (1983), S. 1079-1090 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Cellulose triacetate (CTA) forms cholesteric mesophases in trifluoroacetic acetic acid (TFA) and mixtures of TFA and CH2Cl2, 1,2-dichloroethane (1,2-DCE), and CHCl3. Cholesteric pitches and solution flow times indicate that the order of solvent powers is TFA-CH2Cl2 〉 TFA-1,2-DCE 〉 TFA 〉 TFA-CHCl3, which is the order of decreasing acidity of the solvent systems. With TFA-CH2Cl2 as solvent, the one-fourth power of the pitch varies inversely with the CTA concentration, and increases linearly with temperature. The pitch increases exponentially with time and increases faster the more acidic the solvent. In a magnetic field a cholesteric to nematic transition occurs. A minimum in solution viscosity occurs at 34% w/v of CH2Cl2 for solutions in TFA-CH2Cl2. The miscibility gap as a function of molecular weight depends on the solvent composition and is smaller the higher the acidity of the solvent. Agreement between the experimentally observed A and B points and the theoretical points is better for the Khokhlov and Semenov theory for semiflexible chains than for the original Flory theory or the Flory-Ronca modification.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 21 (1983), S. 537-551 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Ion implantation of impurities into thin films of poly(p-phenylene sulfide) (PPS) is found to increase the conductivity of the material by up to 12 orders of magnitude. The increase is stable under exposure to ambient conditions, in contrast to the instability of the conductivity increases in PPS produced by chemical doping with AsF5. PPS films 0.1-0.2 μm thick are spin cast from solution onto interdigitated electrodes patterned on an oxidized silicon substrate. The room-temperature interelectrode resistance is measured as a function of implantation fluence. An estimate of film conductivity is obtained from this resistance with a simple model for the electrode and film geometry. A first experiment yielded similar conductivity increases for implantation of either arsenic or krypton. At a fluence of 1 × 1016cm-;2, which corresponds to an average impurity concentration of 2.5 × 1021cm-3, the conductivity reaches an apparently saturated value of 1.5 × 10-5 (Ω cm)-1. Infrared spectra of the films before and after implantation suggest that crosslinking may be present in the implanted films, and Auger studies show stoichiometric changes throughout the implanted layer. These results suggest that the observed conductivity changes are the result of molecular rearrangements produced by the implantation rather than the result of specific chemical doping. Specific chemical doping may, however, explain the results of a second experiment in which implantation of bromine resulted in substantially larger conductivities found to increase at an approximate linear rate from a value of 1.0 × 10-4 (Ω cm)-1 at a fluence of 1 × 1016 cm-2 to a value of 4.0 × 10-4 (Ω cm)-1 at a fluence of 3.16 × 1016 cm-2.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 21 (1983), S. 1195-1203 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Dielectric methods have been employed to study the high-pressure behavior of a polyurethane elastomer (Solithane 113) in the vicinity of its α transition. The α-loss peak is shifted to higher temperatures and broadened somewhat with the application of hydrostatic pressure up to 6.4 kbars. The slope of Tα vs. P, or dTα/dP, obtained at low frequencies was found to be equal to dTg/dP obtained by a volumetric method. Moreover, it attained a nonzero limiting value at high pressures for each frequency tested (3 - 30,000 Hz) and the limiting value itself increased with increasing frequency from 10.5°C/kbar at 3 Hz to 18°C/kbar at 30,000 Hz. The activation enthalpy ΔH* was found to be nearly constant over the pressure range tested, but the activation volume ΔV* decreased with increasing pressure. The relation dTα/dP = T (ΔV*/ΔH*) was shown to hold for the elastomer.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 21 (1983), S. 2607-2607 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2011-08-18
    Description: A simplified version of moire deflectometry for flow visualization is presented. The modification comprises replacement of the second grating, the ground glass screen, and the camera with a plate film holder to obtain a shadow picture. Postanalysis proceeds by placing a grid transparency of the same periodicity of the remaining glass grating on the negative for projection viewing. The rotational angle between the grating and the plate alters the moire fringe periodicity. Use of the method in studying flows is predicted to reveal weak density gradient areas and shocks.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 22; Mar. 1
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-28
    Description: A ride quality meter is disclosed that automatically transforms vibration and noise measurements into a single number index of passenger discomfort. The noise measurements are converted into a noise discomfort value. The vibrations are converted into single axis discomfort values which are then converted into a combined axis discomfort value. The combined axis discomfort value is corrected for time duration and then summed with the noise discomfort value to obtain a total discomfort value.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-28
    Description: This is a summary and discussion of the state of the art in the use of laser diagnostics in fluid and plasma dynamics. This will encompass: interferometry, scattering, spectroscopy, and velocimetry. Examples of such applications will be provided in the area of fluid dynamics of particle generation and breakup, analysis of three-dimensional density fields, and applications in combustion.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA PAPER 83-1683
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-28
    Description: The position and velocity of optically levitated glass spheres (radii 10-20 microns) movng in a gas are measured accurately, rapidly, and continuously using a high-speed rotating polygon mirror. The experimental technique developed here has repeatable position accuracies better than 20 microns. Each measurement takes less than 1 microsec and can be repeated every 100 microsec. The position of the levitated glass spheres can be manipulated accurately by modulating the laser power with an acoustic optic modulator. The technique provides a fast and accurate method to study general particle dynamics in a fluid.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 54; 1643-164
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...