ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (105)
  • Analytical Chemistry and Spectroscopy  (98)
  • AERODYNAMICS
  • Cell & Developmental Biology
  • METEOROLOGY AND CLIMATOLOGY
  • 1980-1984  (105)
  • 1935-1939
  • 1982  (105)
  • Chemistry and Pharmacology  (105)
Collection
  • Articles  (105)
Keywords
Publisher
Years
  • 1980-1984  (105)
  • 1935-1939
Year
Topic
  • 1
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, TLC ; Binary solvent mixtures ; New solvent polarity ranking ; Optimization ; Window diagram ; Cluster center ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ΔRf, the separation between a pair of compounds on a thin layer chromatographic plate, can be predicted as a function of solvent composition for certain binary systems. This allows the prediction of optimum solvent composition for separating a mixture of compounds by thin layer chromatography. A new solvent polarity ranking, based on calculation of ΔRf is described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 52-53 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Instrumentation in gas chromatography ; Capillary Injector ; Injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, N.Y. : Wiley-Blackwell
    Journal of Cellular Biochemistry 20 (1982), S. 283-292 
    ISSN: 0730-2312
    Keywords: insulin receptor ; basic somatomedin receptor ; human placenta ; peptide maps ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: The disuccinimidy! suberate, affinity-labeling procedure, and proteolytic mapping techniques have been employed to characterize further the human placental receptors for insulin and basic somatomedin. Electrophoretic analysis of the basic somatomedin receptor, selectively crosslinked to 125I basic somatomedin in the presence of excess native insulin revealed, under reducing conditions, major labeled constituents of 270-280 and 125-140 kd, substantiating our previous work employing a photoaffinity labeling reagent. Affinity labeling also demonstrated the presence of less intensely labeled components with apparent molecular weights of 40 and 45 kd but failed to reveal a distinct 90- to 100-kd species observed in parallel experiments with insulin. In the absence of β-mercaptoethanol, all components specifically labeled with 125I basic somatomedin migrated in the 300- to 400-kd range. In comparison, selective affinity labeling of the insulin receptor in the presence of excess native basic somatomedin revealed components, upon electrophoresis under reducing conditions, with apparent molecular weights of 270-280, 125-140, 90-100, and 40 kd. The major insulin-labeled component (125-140 kd) comigrated with the major constituent (125-140 kd) selectively labeled with basic somatomedin. When digestion was performed prior to solubilization, chymotryptic and tryptic proteolysis of the membrane-localized selectively labeled insulin, and basic somatomedin receptors yielded quite similar gel electrophoretic maps. However, when digestion was done subsequent to solubilization, chymotryptic and tryptic proteolysis of selectively labeled insulin and basic somatomedin receptors solubilized in SDS yielded similar but not identical gel electrophoretic maps. We conclude that the receptors for basic somatomedin and insulin are highly homologous structures with respect to their disulfide crosslinked composition, and with respect to the size of the major components detected by selective affinity-labeling procedures. Nevertheless, the detection of electrophoretically distinct labeled receptor components upon analysis of specifically labeled intact or proteolytically digested receptors points to subtle differences between the polypeptide compositions of the two receptors.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0306-042X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method for the quantitative determination of 1,2,3-propanetrioltrinitrate (nitroglycerin) in human plasma by gas chromatography mass spectrometry has been developed. After addition of 1,2,3-propanetriol(15N)trinitrate as internal standard, plasma (1 ml) is extracted by a mixture of pentane and methyl acetate (90:10). The extracts are purified by partition between, first, the extraction solvent and a mixture of acetonitrile and water (60:40) and, secondly, the resultant aqueous phase and benzene. The solvent is evaporated to a small volume before injection. The fragment ions at m/z 46 and 47 are monitored for the measurement of the [NO2]+ and [15NO2]+ ions using electron impact ionization. The mean recovery (%) ±SD in blind plasma samples spiked with amounts in the concentration range 0.35-3.52 nmol I-1, was 97.4 ± 9.0 (n = 58). Within a day, recovery experiments gave rise to coefficients of variation of 9.6, 6.4 and 2.7% at the levels 0.44,0.88 and 11 nmol I-1, respectively. Concentrations in plasma down to about 0.2 nmol I-1 (50 pg mI-1) could be estimated. Percent recovery of duplicate determinations in the range 0.5-1.96 nmol I-1± SD was 99.4 ± 6.0 (n = 80).
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The 13C NMR spectrum of ellipticine has been re-interpreted by reference to model compounds, and correlated with the spectra of a number of new ellipticine derivatives.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 18 (1982), S. 92-97 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The vicinal proton coupling constants were obtained for some 6-membered ring unsaturated heterocyclic compounds. The R values and ring dihedral angles were determined and found to be consistent with half-chair conformations. Relative to saturated heterocyclic compounds, the effect of the sulfur atom on ring puckering was attenuated. However, an increase in ring puckering resulted from the sulfone group and was attributed to torsional energy.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 205-211 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Triple quadrupoles are becoming widely used in sequential mass spectrometry. The observed spectra are very dependent upon the choice of instrument parameters such as the gas target density, the mode of operation of the central quadrupole, and the direct current levels of the quadrupoles (rod-offsets) which determine the collision energy and the maximum mass resolutions in each analysing quadrupole. The influence of each of the instrument parameters is discussed with examples of experimental measurements of performance, and the optimum choice of modes of operation is determined.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 17 (1982), S. 212-219 
    ISSN: 0030-493X
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detailed exploration of the application of triple quadrupoles in sequential mass spectrometry has been carried out using dimethylmorpholinophosphoramidate as a case study of an ion of relatively high mass and complex structure. Both metastable ion decomposition and dissociation by low energy collision were examined. Variation of the basic instrument parameters allowed the investigation of the cross-section for dissociation as a function of collision energy, the change in fragmentation patterns with collision energy, the kinetic energy distributions of daughter ions and the overall kinetics of dissociation in a succession of ion decomposition sequences giving daughter and granddaughter ions. The daughter ions could also be produced in the source region and examined separately so that a genealogical tree could be established.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 13 (1982), S. 53-55 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The pressure dependences at room temperature of the translational lattice modes and of the ν2 and ν4 internal bending modes of the ReO4- ion in solid NH4ReO4 are reported. There is no evidence of any phase transition up to a pressure of 15 kilobar. The pressure coefficients of the translational modes are 2.0 cm-1 GPa-1 and 3.0 cm-1 GPa-1 for the Bg and Eg modes respectively. The pressure coefficients of the bending modes are 1.0 cm-1 GPa-1 and 5.4 cm-1 GPa-1 for the Bg and Ag components of ν2, and 4.1 cm-1 for the overlapped Bg and Eg components of ν4.The symmetry assignments of the low frequency lines in the spectrum were checked by means of polarized Raman spectra of a single crystal. The previous assignments are correct.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 134-138 
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography ; Reversed phases ; Preloading with solvent vapors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The chromatographic behavior of some hydrocarbons and some of their nitro derivates after preconditioning with solvent vapors has been investigated. After preloading with cyclohexane or hexane an improved separation of some sample pairs is observed. Furthermore, inversion of Rf values takes place. The preloading of the reversed-phase plates permits utilization of mobile phase with higher water content, thus leading to a significant shortening of developing time.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...