ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • EARTH RESOURCES AND REMOTE SENSING  (140)
  • Analytical Chemistry and Spectroscopy  (103)
  • INSTRUMENTATION AND PHOTOGRAPHY  (51)
  • Biochemistry and Biotechnology
  • 1995-1999
  • 1980-1984  (327)
  • 1955-1959
  • 1982  (327)
Collection
Keywords
Publisher
Years
  • 1995-1999
  • 1980-1984  (327)
  • 1955-1959
Year
  • 1
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-28
    Description: High-altitude radar and thermal imagery collected by the NASA research aircraft WB57F were used to examine the structural setting and distribution of radiant temperatures of geothermal anomalies in the Pilgrim Springs, Alaska area. Like-polarized radar imagery with perpendicular look directions provides the best structural data for lineament analysis, although more than half the mapped lineaments are easily detectable on conventional aerial photography. Radiometer data and imagery from a thermal scanner were used to evaluate radiant surface temperatures, which ranged from 3 to 17 C. The evening imagery, which utilized density-slicing techniques, detected thermal anomalies associated with geothermal heat sources. The study indicates that high-altitude predawn thermal imagery may be able to locate relatively large areas of hot ground in site-specific studies in the vegetated Alaskan terrain. This imagery will probably not detect gentle lateral gradients.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: Remote Sensing of Environment; 12; Nov. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: The routine correction of MAGSAT vector magnetometer data for external field effects such as the ring current and the daily variation by filtering long wavelength harmonics from the data is described. Separation of fields due to low altitude sources from those caused by high altitude sources is affected by means of dual harmonic expansions in the solution of Dirichlet's problem. This regression/harmonic filter procedure is applied on an orbit by orbit basis, and initial tests on MAGSAT data from orbit 1176 show reduction in external field residuals by 24.33 nT RMS in the horizontal component, and 10.95 nT RMS in the radial component.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: E82-10314 , NASA-CR-168889 , NAS 1.26:168889
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: Earth's atmosphere reduces a sensors ability in currently discriminating targets. Using radiometric correction to reduce the atmospheric effects may improve considerably the performance of an automatic image interpreter. Several methods for radiometric correction from the open literature are compared leading to the development of an atmospheric correction system.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: E83-10079 , NASA-CR-165122 , NAS 1.26:165122 , INPE-2471-PRE/160 , Reuniao Anual da SBPC; Jul 01, 1981; Salvador, Bahia
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Description: The coal mining district in southeastern Santa Catarina State is considered one of the most polluted areas of Brazil. The author has identified significant preliminary results on the application of MSS-LANDSAT digital data to monitor the coal refuse areas and its environmental consequences in this region.
    Keywords: EARTH RESOURCES AND REMOTE SENSING
    Type: E83-10066 , NASA-CR-169577 , NAS 1.26:169577 , INPE-2410-PRE/119 , Intern. Symp. on Remote Sensing of Environ.; Jun 02, 1982 - Jun 09, 1982; Buenos Aires
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-13
    Description: Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy IV; Fourth Conference; Mar 08, 1982 - Mar 10, 1982; Tucson, AZ
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 24 (1982), S. 847-856 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The accuracy of kinetic and stoichiometric data obtained from most laboratory-scale continuous-culture equipment, particularly involving gaseous measurements, may be much lower than many workers realize, despite the use of good quality instruments. For example, errors in specific oxygen uptake measurements (QO2) easily can be as high as ±100%. This article assesses the accuracies of individual instruments and of the overall system in greater detail than has previously been reported and suggestions are made as to how the errors can be reduced to acceptable levels.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 24 (1982), S. 127-141 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Isoelectric soya-protein precipitate densities were measured for mean particle sizes ranging from 3.4-65 μm by gradient centrifugation, centrifugation in water-immiscible solvents, tracerdilution, gravity sedimentation of isolated particles. Coulter counter volume determination, and a comparison of Coulter counter and centrifugal sedimentation size distributions. The immiscible system and tracer dilution methods were both found to be unreliable due to experimental uncertainties. The Coulter counter volume measurement indicated the existence of a density-size relationship with the aggregate density decreasing as the size increased. Comparison with sedimentation measurements showed that the Coulter counter measures 80% of the total aggregate volume for 6-μm particles. The relation between aggregate density (ρa, kg m -3) and size (d, μm) was measured for isoelectric soya protein and casein precipitated by ammonium sulfate, using a comparison of the Coulter counter size distribution and centrifugal sedimentation. The functions were described for soya by \documentclass{article}\pagestyle{empty}\begin{document}$$ \rho _a - 1004 = 246d^{ - 0.408} $$\end{document} and for casein by \documentclass{article}\pagestyle{empty}\begin{document}$$ \rho _a - 1136 = 31d^{ - 0.441} $$\end{document} The gradient centrifugation method measured the buoyant density of hydrated protein precipitate which was independent of size, and is consistent with an aggregate structure consisting of primary particles. However, the aggregate structure was not described for all sizes by the theoretical cubic packing of hard-sphere primary particles, nor by the successive random addition of primary particles. The density-size functions indicated up to a fivefold difference in Stokes settling velocities compared to those calculated assuming a constant density difference.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0935-6304
    Keywords: Thin-layer chromatography, TLC ; Binary solvent mixtures ; New solvent polarity ranking ; Optimization ; Window diagram ; Cluster center ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ΔRf, the separation between a pair of compounds on a thin layer chromatographic plate, can be predicted as a function of solvent composition for certain binary systems. This allows the prediction of optimum solvent composition for separating a mixture of compounds by thin layer chromatography. A new solvent polarity ranking, based on calculation of ΔRf is described.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 52-53 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Instrumentation in gas chromatography ; Capillary Injector ; Injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗