ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • NDE  (8)
  • Bone  (5)
  • Wheat
  • Springer  (14)
  • PANGAEA
  • 2020-2023
  • 2000-2004
  • 1980-1984  (14)
  • 1970-1974
  • 1981  (14)
Collection
Publisher
  • Springer  (14)
  • PANGAEA
Years
  • 2020-2023
  • 2000-2004
  • 1980-1984  (14)
  • 1970-1974
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Keywords: Histomorphometry ; Bone ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 89-99 
    ISSN: 1432-0827
    Keywords: Soluble proteoglycans ; Resistant proteoglycans ; Collagen ; Bone ; Cartilage
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Soluble proteoglycans (SPG) were extracted from bovine (BCC) and human (HCC) costal cartilages by the dissociative method using 4 M guanidinium chloride (GuHCl). Proteoglycans which are resistant to extraction (RPG) were obtained following collagenase digestion or hydroxylamine treatment of the cartilage residues. Similarly, SPG were extracted from bovine metaphyseal and cortical bone using EDTA. The RPG were extracted from the bones using hydroxylamine. Density gradient fractionation under dissociative conditions of cartilage SPG and RPG followed by chromatography on Sepharose 2B revealed that A1D1 RPG are smaller than the SPG. SPG reacted with either collagenase or hydroxylamine are also smaller than the parent SPG. A1D1 fractions obtained from BCC-SPG and RPG or from mixtures of SPG and acid-soluble collagen are free of hydroxyproline. Hydroxyproline is not completely separated from HCC-RPG. Density gradient fractionation of bone proteoglycans and Sepharose chromatography of the A1 and A1D1 fractions showed that those obtained from metaphysis are larger than those from cortical bone. This was attributed to the presence of calcified cartilage in metaphyseal bone. The A1D1 fractions of the metaphyseal proteoglycans seemed to undergo self-association since this fraction is larger than the A1 fraction from which it is derived. Cortical bone proteoglycans do not behave similarly. Density gradient purification under dissociative conditions failed to separate hydroxyproline from the proteoglycans obtained from bone. It is hypothesized that in bone proteoglycans and collagen might be linked.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 499-504 
    ISSN: 1432-0827
    Keywords: Bone ; Collagen ; Density
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The density of a bovine cortical bone matrix sample was found in water, several ethanol-water solutions, and in the dried state. Previously the density of the same mineralized bone was found fresh and when desiccated. The volume in each state was estimated from the dimensional changes axially, tangentially, and radially. Confirmation was found by determining the density of dried specimens upon immersion in xylene. The amount of imbibed xylene provided an estimate of the free pore volume in the dried matrix. The volume fraction of the solid constituent, S, in the wet matrix was found to be 0.57, from which the density of S in various solutions was calculated. Density of wet matrix in 0.15 M saline: 1.180 g/cc; for dried matrix, 1.246 g/cc. Density of wet S in saline: 1.33 g/cc; for dried S, 1.42 g/cc, which matches published values for collagen molecules. Dimensional changes between wet and dried state of matrix match published values for artificially cross-linked rat tail tendon fibers. Axially: 1.04, by area: 2.27; by volume: 2.62. Estimate of intrafibrillar volume, assuming 80% of mineral is within fibrils: 0.73 cc/g dry collagen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 631-639 
    ISSN: 1432-0827
    Keywords: Bone ; Osteopenia ; Noninvasive monitoring
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Radiological techniques were utilized for monitoring progressive changes in compact bone in the tibia of monkeys during experimentally induced osteopenia. Bone mass loss in the tibia during restraint was evaluated from radiographs, from bone mineral analysis, and from images reconstructed from gamma ray computerized tomography. The losses during 6 months of restraint tended to occur predominantly in the proximal tibia and were characterized by subperiosteal bone loss, intracortical striations, and scalloped endosteal surfaces. Bone mineral content in the cross section of the tibia declined 17–21%. Tomography demonstrated endosteal widening and reduced mineral content per unit of thickness of cortical bone. In 6 months of recovery, the mineral content of the proximal tibia remained depressed. Effects of the dynamic environment on local-regional changes in various skeletal areas are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 35-39 
    ISSN: 1432-0827
    Keywords: Copper ; Resorption ; Bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary An investigation of the role of copper in bone metabolism was undertaken. Explanted calvaria from 6-day-old mice were grown for 48 h in medium with and without the addition of copper sulfate. Active resorption was found to be significantly inhibited in the presence of copper sulfate concentrations of 10−6M and above. Copper sulfate concentrations of 10−5M and above inhibited hydroxyproline, protein, and DNA synthesis. Lower concentrations were ineffective. The effect of 5 × 10−6M copper sulfate on resorption was reversible. Several other compounds were tested for similar effects and at 5 × 10−6M were found to inhibit bone resorption in the order: copper sulfate 〉 brown gold chloride 〉 sodium aurothiomalate 〉 zinc sulfate 〉 sodium sulfate. The copper sulfate effect was twice that of sodium aurothiomalate, and sodium sulfate was not significantly inhibitory. The results suggest that the high serum copper levels associated with rheumatoid arthritis may reflect the activity of a hypothetical control mechanism of bone resorption. In the diseased state this would act to restore the normal rate of bone resorption.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 85-111 
    ISSN: 1573-4862
    Keywords: Holographic reconstruction ; ultrasound ; NDE ; Rayleigh-Sommerfeld formula
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract For the purpose of ultrasonic nondestructive testing of materials, holography in connection with digital reconstruction algorithms has been proposed as a modern tool to extract crack sizes from ultrasonic scattering data. Defining the typical holographic reconstruction algorithm as the application of the scalar Kirchhoff diffraction theory to backward wave propagation, we demonstrate its general incapability of reconstructing equivalent sources, and hence, geometries of scattering bodies. Only the special case of a planar measurement recording surface, that is to say, a hologram plane, and a planar crack with perfectly rigid boundary conditions parallel to the hologram plane and perpendicular to the incident field yields a nearly perfect correlation between crack size and reconstructed image; the reconstruction algorithm is then referred to as the Rayleigh-Sommerfeld formula; it therefore represents the optimal case matched to that special geometrical situation and, hence, may be interpreted as a quasi-matched spatial filter. Using integral equation theory and physical optics, we compute synthetic holographic data for a linear cracklike scatterer for both plane and spherical wave incidence, the latter case simulating a synthetic aperture impulse echo situation, thus illustrating how the Rayleigh-Sommerfeld algorithm or its Fresnel approximation increasingly fail for cracks inclined to the hologram plane and excited nonperpendicularly. Furthermore, we point out how the physical data recording process may additionally influence the reconstruction accuracy, and, finally, guidelines for a careful and serious application of these holographic reconstruction algorithms are given. The theoretical results are supported by measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 203-207 
    ISSN: 1573-4862
    Keywords: ultrasonics ; synthetic aperture ; spatial frequency ; interior imaging ; acoustic microscopy ; defect detection ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A new acoustic synthetic aperture geometry is demonstrated in which the image field is sampled in the spatial frequency domain. This means the sampled field is recorded in a particularly convenient form for presentation to the back propagation algorithms used to reconstruct the field at the object plane. The method has applications in interior visualization. It is difficult to image the interior of solid objects using lens based imaging systems because a different lens geometry must be used for each distinct object material. The system presented here overcomes such problems since both the angular variation of the transmission coefficient at the object-water interface and the aberrations introduced by the velocity mismatch at the object surface may be readily compensated for in the back propagation routine. Experimental results are presented illustrating the detection of four half wavelength diameter defects, spaced by three wavelengths, at a depth of eight wavelengths below the surface of an aluminum block.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 161-172 
    ISSN: 1573-4862
    Keywords: elastodynamic inverse scattering ; ultrasonics ; data reduction ; ill-posed problems ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The practical significance of ill-posedness in a data reduction problem is reviewed. Inverse elastodynamic scattering is shown to be ill-posed in general, although suitably restricted problems may be well-posed. These results underscore the need to analyze carefully the errors of data reduction problems in NDE, and to focus attention on final results of an NDE exercise, rather than on intermediate steps.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...