ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (467)
  • INSTRUMENTATION AND PHOTOGRAPHY  (109)
  • SPACECRAFT DESIGN, TESTING AND PERFORMANCE  (92)
  • 1980-1984  (668)
  • 1984  (351)
  • 1981  (317)
Collection
Keywords
Publisher
Years
  • 1980-1984  (668)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 509-519 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The deterioration of polyolefin, poly(ethylene terephthalate), and polyamide films under soil burial conditions extending up to 32 months has been investigated. Based on changes in their elongation at break, the films can be ranked in order of increasing sensitivity to degradation: Polyester ≃ polypropylene 〈 low-density polyethylene ≃ high-density polyethylene 〈 nylon 6.6. The degraded nylon 6.6 and polyethylene films were characterized by infrared and luminescence spectroscopy and scanning electron microscopy, as well as by wet analysis for hydroperoxides. From a comparison with the well-known oxidative sensitivity of nylon 6.6 in oxygenated water at slightly elevated temperatures, the rapid deterioration of nylon 6.6 film during soil burial was also concluded to be an oxidative process. The somewhat smaller, but significant, embrittlement of the polyethylenes studied could not be simply explained by thermal oxidation (with only trace oxidation products detectable) or microbiological attack (deterioration being unaffected by surface activation to enhance wettability).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 19 (1981), S. 2817-2834 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermal degradation behavior of poly(1,3-phenylene isophthalamide) and poly(chloro-2,4-phenylene isophthalamide) was investigated with the aid of some appropriate model compounds. The pyrolysis products of these materials were identified by gas chromatography (GC), gas chromatography/Fourier transform infrared spectroscopy (GC/FT-IR), and gas chromatography/mass spectrometry (GC/MS). The residual chars were characterized by IR spectroscopy. Thermogravimetric analysis (TGA) was applied to study the effect of end-group concentration on the degradation characteristics of the two polyamides. Kinetic parameters that describe the thermal degradation of the polyamides were also evaluated by TGA. The results of this investigation suggest that the thermal decomposition of these aromatic polyamides involves homolytic as well as hydrolytic cleavages of the amide units.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 19 (1981), S. 321-334 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Optical-absorption, fluorescence, and Raman spectra for solutions, suspensions, and precipitates of poly(1,6-di-p-toluene sulfonoxy-2,4-hexadiyne) in and from nitrobenzene, acetone, and chloroform are presented. These are interpreted in terms of the occurrence of two forms of the polymer chain; a quasicrystalline form with properties close to those of single crystal polymer and a chain-extended form occurring in solution and colloidal particles, with an absorption energy of about 2.5 eV (20,000 cm-1). No evidence is found for the presence of very short polymer chains in partially polymerized monomer at low conversion. The relationship of these results to those for deformed single crystals is briefly discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-27
    Description: An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-27
    Description: A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Human fibrinogen was treated with thrombin in the presence of fibrinoligase (Factor XIIIa) and calcium ion at pH 8.5, ionic strength 0.45, and the ensuing polymerization was interrupted at various time intervals (t) both before and after the clotting time (tc) by solubilization with a solution of sodium dodecyl sulfate and urea. Aliquots of the solubilized protein were subjected to gel electrophoresis on polyacrylamide gels after disulfide reduction by dithiothreitol and on agarose gels without reduction. The degree of γ-γ ligation was determined from the former. The latter provided the size distribution of ligated end-to-end sequences produced by splitting the ligated staggered overlapped oligomers down the middle, for degrees of polymerization, x, from 1 to 10. Addition of fibrinoligase (in which the activating thrombin had been inhibited by p-nitrophenyl-p′-guanidinobenzoate, NPGB) to Kabi fibrinogen showed the presence of small amounts of ligatable oligomers. Addition of fibrinoligase to a polymerizing mixture in which the action of thrombin had been stopped before clotting by NPGB produced the same distribution of ligated end-to-end sequences that was obtained when fibrinoligase was originally present, at least for reaction times up to 0.7 of the clotting time. The kinetics of γ-γ ligation by fibrinoligase acting on a polymerized mixture stabilized by NPGB were followed. The reaction was first order in the concentration of ligatable γ-γ junctions and the initial velocity was proportional to the enzyme concentration. The time evolution of size distribution of ligated end-to-end sequences agreed with a theory based on random ligation of ligatable junctions.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 23 (1984), S. 2067-2081 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Resonance Raman spectra of the nucleoside 5′-monophosphates UMP, CMP, AMP, and GMP have been obtained with 266- and 213-nm radiation, the fourth and fifth harmonics of a Nd:YAG laser. The 266-nm radiation is resonant with the states giving rise to the first absorption band of the bases. The resulting spectra are in agreement with those reported previously using similar wavelength excitation but are generally of better quality. The 213-nm radiation is resonant with those states giving rise to the second strong absorption band of the bases. The spectra obtained with this wavelength show several new features relative to the 266-nm spectra, including strong enhancement of modes of the pyrimidines with a character similar to the e2g ν8 mode of benzene, relative enhancement of ring modes at 1580 and 729 cm-1 in AMP, and strong enhancement of the 1670-cm-1 C = O mode of GMP. These enhancements are discussed in terms of previously reported preresonance behavior and predicted intensities based on CNDO bond-order changes and normal-mode calculations. The results of a preliminary study of the effect of the interaction of GMP with cis-dichlorodiammineplatinum(II) on the 213-nm resonance Raman spectrum is also discussed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 23 (1984), S. 2157-2172 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effects of organic solvents on the 31P-mr chemical shifts of various phosphate diesters have been investigated in water and mixed-organic solvent systems. The addition of organic solvents to cyclic phosphates and to diethyl phosphate causes large upfield shifts of the phosphorus resonance which are attributed to solvent-induced changes in the local hydration of the phosphodiester group. This is consistent with the fact that there is an inverse correlation between the hydrogen-bond-donating ability of the solvents and the magnitude of the shifts they induce. Other possible interpretations, such as solvent-induced ion pairing and solvent-induced conformational changes, appear to be eliminated. Fourier-transform ir study of the cyclic nucletides reveals that there are also large solvent-induced shifts in the frequency of the antisymmetric OPO stretching frequency, and a comparison of the two types of measurements indicates that there is a linear correlation between shifts observed in the ir and in the 31P-nmr spectra. With UpU, the solvent-induced 31P-nmr shifts are ∼3 times smaller than those observed with the cyclic phosphates and the solvent-induced shift of the OPO band is reduced (factor of ∼1.7) as compared with the cyclic phosphates. With the single-stranded polynuclotides, poly(C) and poly(U), the solvent-induced shifts in both the nmr and ir are quite small (∼0.1 ppm and ∼1 cm-1). The very small solvent effects observed with poly(U) and poly(C) are attributed to a combination of steric effects and a polyelectrolyte effect which maintains a high density of counterions with waters of hydration in the vicinity of the charged backbone and makes the phosphates much less susceptible to solvent-induced changes in hydration.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...