ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (474)
  • INSTRUMENTATION AND PHOTOGRAPHY  (91)
  • 1980-1984  (565)
  • 1982  (290)
  • 1981  (275)
Collection
Publisher
Years
  • 1980-1984  (565)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 509-519 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The deterioration of polyolefin, poly(ethylene terephthalate), and polyamide films under soil burial conditions extending up to 32 months has been investigated. Based on changes in their elongation at break, the films can be ranked in order of increasing sensitivity to degradation: Polyester ≃ polypropylene 〈 low-density polyethylene ≃ high-density polyethylene 〈 nylon 6.6. The degraded nylon 6.6 and polyethylene films were characterized by infrared and luminescence spectroscopy and scanning electron microscopy, as well as by wet analysis for hydroperoxides. From a comparison with the well-known oxidative sensitivity of nylon 6.6 in oxygenated water at slightly elevated temperatures, the rapid deterioration of nylon 6.6 film during soil burial was also concluded to be an oxidative process. The somewhat smaller, but significant, embrittlement of the polyethylenes studied could not be simply explained by thermal oxidation (with only trace oxidation products detectable) or microbiological attack (deterioration being unaffected by surface activation to enhance wettability).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 19 (1981), S. 2817-2834 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermal degradation behavior of poly(1,3-phenylene isophthalamide) and poly(chloro-2,4-phenylene isophthalamide) was investigated with the aid of some appropriate model compounds. The pyrolysis products of these materials were identified by gas chromatography (GC), gas chromatography/Fourier transform infrared spectroscopy (GC/FT-IR), and gas chromatography/mass spectrometry (GC/MS). The residual chars were characterized by IR spectroscopy. Thermogravimetric analysis (TGA) was applied to study the effect of end-group concentration on the degradation characteristics of the two polyamides. Kinetic parameters that describe the thermal degradation of the polyamides were also evaluated by TGA. The results of this investigation suggest that the thermal decomposition of these aromatic polyamides involves homolytic as well as hydrolytic cleavages of the amide units.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Physics Edition 19 (1981), S. 321-334 
    ISSN: 0098-1273
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Optical-absorption, fluorescence, and Raman spectra for solutions, suspensions, and precipitates of poly(1,6-di-p-toluene sulfonoxy-2,4-hexadiyne) in and from nitrobenzene, acetone, and chloroform are presented. These are interpreted in terms of the occurrence of two forms of the polymer chain; a quasicrystalline form with properties close to those of single crystal polymer and a chain-extended form occurring in solution and colloidal particles, with an absorption energy of about 2.5 eV (20,000 cm-1). No evidence is found for the presence of very short polymer chains in partially polymerized monomer at low conversion. The relationship of these results to those for deformed single crystals is briefly discussed.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-27
    Description: An experimental version of a thinned illuminated buried-channel 512 x 320 pixel CCD with reduced amplifier input capacitance has been produced which is characterized by lower readout noise. Changes made to the amplifier are discussed, and readout noise measurements obtained by several different techniques are presented. The single energetic electron response of the CCD in the electron-bombarded mode and the single 5.9 keV X-ray pulse height distribution are reported. Results are also given on the dark current versus temperature and the spatial frequency response as a function of signal level.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-18
    Description: A diode-laser-based, ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microns. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N2O, O3, and CH4 between 1170 and 1200/cm, using both a single-frequency swept IF channel and a 64-channel RF spectral line receiver with a total IF coverage of 1600 MHz.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics; 21; Jan. 15
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-27
    Description: A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Solid state imagers for astronomy; June 10, 11, 1981; Cambridge, MA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy IV; Fourth Conference; Mar 08, 1982 - Mar 10, 1982; Tucson, AZ
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 21 (1982), S. 2265-2277 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Human fibrinogen was treated with thrombin in the presence of fibrinoligase (Factor XIIIa) and calcium ion at pH 8.5, ionic strength 0.45, and the ensuing polymerization was interrupted at various time intervals (t) both before and after the clotting time (tc) by solubilization with a solution of sodium dodecylsulfate and urea. Aliquots of the solubilized protein were subjected to gel electrophoresis on polyacrylamide gels after disulfide reduction by dithiothreitol and on agarose gels without reduction. The degree of γ-γ ligation was determined from the former and the size distribution of ligated oligomers, for degree of polymerization x from 1 to 10, from the latter. In some experiments, thrombin was inhibited, after partial polymerization, by p-nitrophenyl-p′-guanidinobenzoate. From these, it was concluded that for thrombin concentration ≤0.013 units/mL and fibrinoligase ≥30 mg/L, oligomer assembly is rapid compared with peptide A release and ligation is rapid compared with assembly. Under these conditions, the theory of the first paper of this series describes rather well the time dependences of the degree of γ-γ ligation, the weight fractions of monomer and small oligomers, and the number- and weight-average degrees of polymerization after solubilization of the staggered overlapped assemblies, each of which splits to give two strands of end-to-end ligated oligomers. The theory assumes that the second A peptide is released by thrombin more rapidly than the first by a factor q, which, from the experimental data, is determined to be 16. The subsequent assembly into staggered overlapped oligomers follows the statistics of linear polycondesation taking into account the presence of both difunctional and monofunctional combining units. For higher thrombin or lower fibrinoligase concentrations, ligation fails to keep pace with oligomer assembly, and the size distributions after solubilization show a higher proportion of very small and a lower proportion of larger ligated oligomers, owing to separation of the staggered overlapped assemblies into smaller fragments.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 591-602 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Reticulated polystyrene-divinylbenzene (PSt-DVB) copolymer membranes or thin sheets were prepared using two different methods. The first method employed a nonsolvating diluent which dissolves the monomer but precipitates the polymer. This resulted in skinned membranes with the skin being nonporous, being either crenelated or smooth. The second method used paraffin wax as the inert phase. The wax was precipitated by cooling, followed by polymerization of the styrene. The wax was then solvent extracted. This resulted in a reticulated structure both on the surface and in the interior of the membrane. The resulting products from the two methods were compared using scanning electron microscopy. The objective of this study was to prepare a skinless, macroporous, crosslinked polystyrene, as polymer I for the preparation of novel interpenetrating polymer network (IPN) materials.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...