ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Occupational Health and Environmental Toxicology  (1)
  • Polymer and Materials Science  (1)
  • Wiley-Blackwell  (2)
  • Nature Publishing Group
  • 1985-1989
  • 1980-1984  (2)
  • 1920-1924
  • 1980  (2)
Collection
Keywords
Publisher
  • Wiley-Blackwell  (2)
  • Nature Publishing Group
Years
  • 1985-1989
  • 1980-1984  (2)
  • 1920-1924
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 25 (1980), S. 2285-2294 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A series of C4-C12 alkyl acrylates and methacrylates was polymerized with starch by irradiating starch-monomer mixtures with 60Co. Homopolymers were extracted with cyclohexane. The amounts of insoluble versus soluble synthetic polymer in polymerization run with alkyl acrylates varied less with the chain length of the alkyl substuent than in the polymerizations run with alkyl acrylates varied less with the chain length of the alkyl substituent than in the polymerizations run with alkyl methacrylates; and the poly(alkyl acrylate) contents of cyclohexane-insoluble fractions were all in the 38-45% range. Synthetic polymer contents of the products from butyl, hexyl, and decyl methacrylates were also close to this range. Octyl and lauryl methacrylate, however, gave high conversions to cyclohexane-soluble poly(alkyl methacrylate) along with little or no unextractable synthetic polymer in the starch-containing fractions. Poly(lauryl methacrylate) could be rendered insoluble by incorporating a small amount of tetramethylene glycol dimethacrylate in the polymerization mixture. In a series of polymerizations run with hexyl acrylate and hexyl methacrylate, lower irradiation doses led to more cyclohexane-soluble polymer and less synthetic polymer in the starch-containing fractions. Enzymatic digestion of starch-soluble polymer and less synthetic polymer in the starch-containing fractions. Enzymatic digestion of starch-containing polymers gave synthetic polymer fractions that were largely insoluble in cyclohexane. Crosslinking is, therefore, probably taking place during these polymerizations; however, we could not eliminate the possibility that reduced solubility was caused by small amounts of residual carbohydrate in these polymer fractions. Ceric ammonium nitrate-initiated polymerizations of butyl acrylate, hexyl acrylate, and butyl methacrylate with starch gave cyclohexane-insoluble polymers that contained 33-39% synthetic polymer. The higher alkyl acrylates and methacrylates produced little or no polymer under these conditions. Starch-containing fractions were tested as absorbents for hydrocarbons. Products prepared from decyl acrylate and lauryl acryle acrylate absorbed about 9 g of isooctane per 1 g of polymer, whereas the lowrer alkyl monomers gave polymers with lower absorbency.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 21-34 
    ISSN: 0197-8462
    Keywords: radiofrequency radiation ; microwaves ; rhesus monkey dosimetry ; microwave dosimetry ; cranial structures ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Temperature increases due to absorption of 1.2 GHz, CW, 70 mW/cm2, radio frequency (RF) energy, were measured in 3.3-cm-radius homogeneous muscle-equivalent spheres, M. mulatta cadaver heads (both detached from and attached to the body) and living, anesthetized M. mulatta heads. Temperatures were measured with a Vitek, Model 101 Electrothermia Monitor and temperature distributions were compared to theoretical predictions from a thermal-response model of a simulated cranial structure. The results show that the thermal response model accurately predicts the temperature distribution in muscle-equivalent spheres, the distribution of temperature in detached M. mulatta heads when exposed from the back of the head, and the distribution of temperature in attached M. mulatta cadaver heads for animals oriented with body parallel to the H-field. The temperature distribution in the detached M. mulatta heads varies markedly with exposure orientation, ie, facing forward, backward, or to the side. The orientation of the M. mulatta cadaver body significantly affects the temperature distribution in the head - with H-field orientation showing high, nonuniform values, and E-field orientation showing low, uniform values. In live animals blood flow produces a significant short-term effect on the temperature distribution in the midbrain, but not the cortex. Midbrain temperatures are both significantly higher and lower than the comparable cadaver measurements, depending on location.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...