ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 456-460 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Theory ; Linearity between peak width and retention data ; Evaluation of GC equipment ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The linearity of the relationship between σT,t2 and (1 + k)2 is studied with the view of using it for the evaluation of GC equipment. Based on appropriate analytical expressions it is concluded that in general this relationship is not linear and that practical procedures for column evaluation should be developed that take this non-linearity into account.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 613-616 
    ISSN: 0935-6304
    Keywords: Gas chromatography, capillary, glass ; 5 mikrometer quartz powder roughening layer fused onto boro silicate glass during drawing process ; Complete procedure given reproducible preparation of stable thick film capillaries ; Static impregnation with 1.5% (w/v) rubber solutions possible ; Very low column bleed, ideal for GC-MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused to the walls. This surface has been found readily deactivated by standard procedures and ideal for the preparation of thick-film glass capillary columns. The method has been thoroughly tested in two independent laboratories to ensure that the procedures described are reproducible.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...