ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Wiley-Blackwell  (413)
  • Oxford University Press  (177)
  • 1975-1979  (590)
  • 1977  (590)
  • 1
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 4 (1977), S. 284-290 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Because of poor field ionization sensitivity or an insufficient number of peaks, conventional reference materials are inadequate for field desorption mass spectrometry. Hexakis (multifluoroalkoxy)cyclotriphosphazenes satisfy a growing need for high molecular weight reference compounds amenable to either electron impact or field ionization. In comparison with tris(perfluoroalkyl)-s-triazine standards, the substituted phosphazenes offer greater volatility, easier synthesis and better mass spetral characteristics. Phosphazene mixtures, in particular, cover a broad mass range in either ionization mode, creating new measurement capabilities for ions at high masses.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 657-665 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Five glass bead-filled polypropylene composites were rheologically characterized at 240°C using two rotational rheometers to obtain low shear-rate data and a capillary rheometer to obtain high shear-rate data. Both steady and dynamic properties were measured at low shear rates. Each composite was also injection molded into tensile and flexural test bars for a mechanical properties profile at 25°C. The tensile modulus was determined from a simple extensional deformation whereas the flexural modulus was determined from a three-point-bend test.The relative shear viscosity and relative loss modulus are different nonlinear functions of the volume fraction of beads at a constant shear rate, while the relative storage modulus appears to be a linear function of bead fraction. The relative viscosity decreases with increasing shear rate and the zero shear-rate data are in very good agreement with the Guth-Gold equation.The relative tensile modulus and relative flexural modulus are each linear functions of bead fraction over the entire range of filler concentration, 0-29 vol percent. From these data it is concluded that a simple correspondence between slow viscous flow and small strain elasticity does not exist for these composites.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 21 (1977), S. 1771-1781 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The vulcanization of butyl rubber by p-quinone dioxime oxidized by red lead and tetrachloroquinone was investigated. The maximum physical effective crosslinking density of the vulcanizates appeared to be when p-quinone dioxime and the oxidizing agent were equimolar. The formation of one physical effective crosslink required one molecule of p-quinone dioxime. Chemical reactions are suggested for the vulcanization steps.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 440-449 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The, nature of polymer surfaces has received increasing attention as the use of these materials, in a variety of forms, increases yearly. Modifications of polymer surfaces for adhesion, friction, and diffusion oriented appiications have necessitated a careful analysis of the surfade region morphology (surface physics) and chemical properties of the surface layer (surface chemistry). The behavior of composite structures has involved the discipline of classical fracture mechanics. The orientation of polymeric species or additives which migrate to the interface may modify the wetting characteristics and, most certainly, the frictional properties in addition to the diffusion of penetrant species beyond the boundary layer. The above topics are discussed within the framework of recent analytical and theoretical developments in surface science. The findings of these recent studies have facilitated many exciting technological advances.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 724-727 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The mechanistic origins of the post extrusion swelling phenomenon have been the subject of considerable debate. Conflicting theories have postulated that it is caused either by (1) deformations at the die entrance which are recovered upon die exit as a consequence of viscoelastic memory or (2) elastic enorgy, which is stored during capillary flow by the action of normal stress, and subsequently released upon die exit or by both (1) and (2). We have described these situations by mathematical models and show that the resulting equations are similar despite different origins. The difficulties in interpreting the results mechanistically are discussed. Empirically, the results can be described as being exponential in capillary residence irrespective of cause.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 19 (1977), S. 247-265 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Pressure drop, gas hold-up, and oxygen transfer were investigated in a sieve tray column, a column with Koch motionless mixers, and a bubble column. The oxygen transfer experiments were conducted using cocurrent flow of gas and liquid under steady-state conditions with oxygen transfer from the gas to the liquid phase. The oxygen transfer rates and efficiencies of the sieve tray column and the column with Koch mixers were found to be superior to those of the conventional bubble column. Gas hold-up was also greater when sieve trays or Koch mixers were inserted in the tower. The pressure drop was found to be primarily due to the liquid head in all three columns.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 19 (1977), S. 493-505 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Oxygen transfer from gas to liquid under steady-state cocurrent flow conditions was modeled using the dispersion model, and the oxygen transfer coefficients were estimated from available data for a column with Koch motionless mixers. The dispersion in the column was estimated for several different gas and liquid flow rates using steady-state tracer experiments. The estimated oxygen transfer coefficients were compared with those estimated using complete mixing and plug flow models. The results indicate that the dispersion model is the most appropriate model for estimating the mass transfer coefficient from the available data.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 21 (1977), S. 2833-2845 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A method of determining the distribution of branching in a polymer is developed employing limiting viscosity numbers (intrinsic viscosity), gel permeation chromatography (GPC), and absolute molecular weight determinations of fractions of the whole polymer. A molecular weight calibration of the GPC column set is first determined empolying these fractions. From the limiting viscosity number measurements of these fractions and their molecular weight distribution determined from the GPC chromatogram, the viscosity-molecular weight relationship is determined by a nonlinear least-squares fitting procedure. For the same molecular weight, the limiting viscosity number of the branched polymer is less than the limiting viscosity number of the linear polymer. From the ratio of the two, the number of branches per unit molecular weight of the branched polymer is calculated. The method was applied to SRM 1476, the standard reference branched polyethylene issued by the National Bureau of Standards. The branching density for the constituents of SRM 1476 rise from zero at molecular weights less than 10,000 to about 6 to 8×10-5 at molecular weights of 50,000 and above. The branching of SRM 1476 was also determined by the method of Drott and Mendelson, giving a result in fair agreement with the above method.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 637-656 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Oxidation-reduction reactions which can destroy high current-density metalstimulating electrodes are avoided when using capacitive electrodes. The results of in vitro and in vivo testing of anodized, high surface area, sintered tantalum electrodes are presented. The corrosion response of the electrodes is excellent; there is no evidence of dissolution of the electrode. A deposit forms on the surface of the electrodes, but has little effect on the voltage response to constant current stimulation. The physiological and histopathological results indicate the capacitive tantalum electrode to be the safest yet tested.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...