ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (1)
  • Geophysics
  • METEOROLOGY AND CLIMATOLOGY
  • Models, Molecular
  • ddc:330
  • Wiley-Blackwell  (1)
  • 1995-1999
  • 1975-1979  (1)
  • 1976  (1)
Collection
Keywords
  • Polymer and Materials Science  (1)
  • Geophysics
  • METEOROLOGY AND CLIMATOLOGY
  • Models, Molecular
  • ddc:330
  • +
Publisher
  • Wiley-Blackwell  (1)
Years
  • 1995-1999
  • 1975-1979  (1)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 177 (1976), S. 437-448 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Probleme, die bei Anwendung der Kompensationsmethode auf IR-spektroskopische Bestimmungen von niedrigen Verzweigungsgraden in Polyäthylenen hoher Dichte auftreten, werden systematisch untersucht. Die erzielbare Genauigkeit wird bestimmt und es wird gezeigt, daß, wenn möglich, eine Korrektur für die Methyl-Endgruppen angewendet werden sollte. Diese ist bei einigen Polymertypen leicht möglich, bei anderen hingegen schwieriger. Als Kompensationskeil im Referenzstrahl des Spektrometers verwendet man besser Polymethylen als hochmolekulares Polyäthylen. Die äußerste Empfindlichkeit, die mit der manuellen Kompensationsmethode erreicht werden kann, liegt bei einem Methylzweig pro 2000 C-Atome. Wenn diese Methode jedoch ergänzt wird durch Computer-Kurvendämpfung und Computer Mittelung über zahlreiche Momentspektren (“C.A.T.”), kann noch eine deutliche Verbesserung im Signal-Rausch-Verhältnis erzielt werden. Damit wird es möglich noch Verzweigungsgrade bis herunter zu 0,1 Methylgruppen pro 1000 C-Atome zu messen.
    Notes: The problems encountered in the infrared spectroscopic estimation of the low levels of chain branching present in high density polyethylene, using the compensation method, are discussed systematically. The precision to be expected has been determined and it is shown that, if possible, a correction should be applied for methyl groups present at the chain ends. This is feasible with some types of polymer but more difficult with others. The compensating wedge in the reference beam of the spectrometer should be made of polymethylene rather than a high molecular weight polyethylene. The ultimate sensitivity of the manual compensation method is about one methyl branch per two thousand carbon atoms. However, when this is supplemented by computer smoothing and off-line computation of average transients (C.A.T.), a significant improvement is obtained in the signal to noise ratio, and branching levels down to 0,1 methyl groups per thousand carbon atoms are readily measured.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...