    Publication Date: 2019-06-27
    Description: An indicator for recording the load at which a fatigue specimen breaks during the last cycle of a fatigue test is described. A load cell is attached to the specimen which is alternately subjected to tension and compression loads. The output of the load cell which is proportional to the load on the specimen is applied to the input of a peak detector. Each time the specimen is subjected to a compression load, means are provided for applying a positive voltage to the rest of the peak detector to reset it. During the last cycle of the tension load the peak detector measures the maximum load on the specimen. Means are provided for disconnecting the load cell from the peak detector when there is a failure in the specimen.
    Keywords: STRUCTURAL MECHANICS
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 176 (1975), S. 963-975 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Die Photolyse von Copolymeren von Methylacrylat und Methylmethacrylat, deren Zusammensetzung sich über den gesamten Bereich erstreckt, wird in filmförmigem und in gelöstem Zustand sowohl im Vakuum als auch unter einer Sauerstoffatmosphäre studiert. In Filmen und unter Vakuum werden Copolymere mit hohem Acrylatgehalt unlöslich und der Grad der Vernetzung und Kettenspaltung kann mit Hilfe der Charlesby-Pinnerschen Gleichung in Anlehnung an die Ergebnisse von Untersuchungen der Sol-Gel Verteilung berechnet werden. Bei geringem Acrylatgehalt bleiben die Polymeren löslich, die Kettenspaltung überwiegt und kann über die Veränderungen im Zahlenmittel des Molekulargewichts gemessen werden. Charakteristische Unterschiede im Ablauf der Kettenspaltung unter den vier verschiedenen Versuchsbedingungen können erklärt werden: physikalisch durch solche Faktoren wie Lage der Glasübergangstemperaturen und Radikalrekombination im „Käfig“ und chemisch als Folge der alternativen Reaktionen, welche die primären Radikale eingehen können.
    Notes: The photolysis of copolymers of methyl acrylate and methyl methacrylate, covering the entire composition range, is studied with the copolymers in the form of film and in solution, under vacuum and in an atmosphere of oxygen. In film under vacuum, copolymers with high acrylate contents become insoluble, and cross-linking and chain scission may be separated by application of the Charlesby-Pinner equation to sol-gel separation data. Otherwise, the polymer remains soluble, chain scission predominates and may be measured by the changes in number average molecular weight. Differences in the characteristics of chain scission under the four sets of conditions are accounted for in terms of physical factors, such as glass transition temperatures and “cage” recombination of radicals, and chemically in terms of the alternative reactions available to the primary radicals involved.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 966-975 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Gas-phase diffusivities for high boiling point organics in common gases are determined by evaporating a single submicron aerosol droplet of the organic species, while it is suspended in an electric field in the path of a polarized laser beam. The droplet size is measured as a function of time by using Mie theory to determine the size from the light scattering data of intensity versus angle. In addition to diffusivities, the Lennard-Jones molecular interaction potential parameter, ∊ii, and the collision diameter σii, are found, by applying the molecular theory of gases to interpret the evaporation rate data. Results are compared with available empirical and semi-theoretical correlations for diffusivities and Lennard-Jones parameters. The low vapor pressure organics used here are dioctyl phthalate (DOP), dibutyl sebacate (DBS) and dibutyl phthalate (DBP), and the carrier gases are helium, nitrogen and carbon dioxide.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 701-708 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An equation of state has been developed for convex nonspherical particles with nonpolar and multipolar forces. The effects of nonsphericity and multipolarity on phase behavior are characterized by a geometric shape parameter and an energy fluctuation parameter, respectively. The equation performs for real fluids better than the Van der Waals equation and as well as the Redlich-Kwong and Peng-Robinson equations.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 48-56 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This paper is an experimental and theoretical study of horizontal stratified gas-liquid two phase flow in a circular tube. Both phases are considered to be in turbulent flow, and the liquid phase flow field is modeled by applying eddy viscosity expressions developed for single phase flow. The pressure drop and in situ volume of liquid are predicted from the gas and liquid flow rates, physical properties, and pipe size by means of an iterative procedure which terminates when calculated gas and liquid pressure drops match. The iterative design procedure is compared with new data for air-water flow in a smooth tube of 63.5 mm ID and with data available in the literature. For conditions corresponding to small amplitude interfacial waves, the average deviation between predicted and experimental results is 24.3% for the pressure drop and 7.7% for the holdup. For roll wave conditions, the corresponding average deviations are 4.6 and 26.4% for pressure drop and holdup, respectively. These results are substantially better than the predictions obtained using the Lockhart-Martinelli correlations.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 25 (1979), S. 958-966 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This article presents a method for predicting local Nusselt numbers for heat transfer to a stratified gas-liquid flow for turbulent liquid/turbulent gas conditions. A mathematical model based on the analogy between momentum transfer and heat transfer is developed and tested, using heat transfer and fluid mechanics data taken for air/water flow in a 63.5 mm I.D. tube. The fluid mechanics parameters required for the prediction of the heat transfer characteristics are obtained in the manner outlined elsewhere. Liquid phase Nusselt numbers predicted by the analogy are shown to be in agreement with experimental results for large and small amplitude wavy interfacial conditions. The circumferential average gas phase Nusselt numbers are in rough agreement with the Dittus-Boelter equation for single phase flow based on flow through a conduit of irregular shape. There is a tendency for the average gas phase Nusselt numbers to scatter about predicted values because of the effects of splashing and droplet deposition on the tube wall in the vicinity of the gas-liquid interface.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 21 (1975), S. 872-878 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The von Karman analogy between heat transfer and momentum transfer in turbulent fluids is shown to apply to heat transfer through wavy liquid films in horizontal, stratified, gas-liquid flow. Nusselt numbers predicted from the analogy are shown to be in good agreement with experimental data for air-water flows involving three-dimensional wavy films and large-amplitude roll waves. The Nusselt numbers encountered with these turbulent water films are found to be in the same range as those associated with condensation of organics in horizontal tubes under stratified flow conditions.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 19 (1975), S. 1829-1835 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new apparatus is described for measuring the permeability of polymer films to sulfur dioxide at partial pressures down to 2 Pa. It employs a permeation tube technique for establishing the partial pressure gradient and a detection system based on the absorption of light at 213.8 nm. Data on the permeability to sulfur dioxide of a range of polymer films are presented and discussed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 13 (1979), S. 543-556 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A high-strength, high-ductility, austenitic stainless steel has been evaluated for use in surgical implants by performing in vivo tests in rats, rabbits, dogs, and rhesus monkeys. This stainless steel, a TRIP (TRansformation Induced Plasticity) steel containing about 4% Mo, was compared with two alloys in current clinical use: Type 316L stainless steel and cast Vitallium. Compared with the other two alloys, cast Vitallium generally had higher resistance to corrosion and superior biocompatibility in all animals. The tests in rats and dogs indicated that the corrosion resistances of the TRIP steel and the Type 316L stainless steel were similar and that the tissue reactions caused by these alloys were also similar. However, in rhesus monkeys, the TRIP steel was shown to be susceptible to stress-corrosion cracking and much more susceptible to crevice corrosion than Type 316L stainless steel. Limited tests in rabbits supported the observation that the TRIP steel is susceptible to stress-corrosion cracking. These inconsistencies in the in vivo tests underline the need for a reevaluation of the popular test techniques and of the animals commonly chosen for assessing the suitability of candidate implant materials. The “worst case” results from the rhesus monkey tests were entirely consistent with previous results obtained from in vitro studies. However, further work must be performed before the behavior of metals in humans, rhesus monkeys, or any other animal, can be predicted with confidence from an in vitro test program.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-27
    Description: Three aluminum honeycomb sandwich conical shells with a 120 apex angle and a 4.6-m (15.0-ft) base diameter were loaded to failure by a uniform external pressure. The cones differed from one another only in the thickness of their respective face sheets. Test specimen details, test procedure, and test results are discussed. Both buckling and prebuckling data are compared with appropriate theoretical predictions, and good agreement was obtained between test and theory. Extensive imperfection measurements were made and reported on the three cones in the as fabricated condition.