ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (338)
  • AIRCRAFT PROPULSION AND POWER  (116)
  • 1980-1984
  • 1975-1979  (454)
  • 1935-1939
  • 1977  (239)
  • 1975  (215)
Collection
Publisher
Years
  • 1980-1984
  • 1975-1979  (454)
  • 1935-1939
Year
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 11 (1977), S. 489-502 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Physical and in vivo (burned rat model) evaluations as wound coverings were performed for 1) a freeze-dried collagen/poly (∊-caprolactone) (PCL) film laminate, 2) a freeze-dried PCL “foam”/PCL film laminate, and 3) a heat-dried collagen/PCL film laminate. Porcine skin and cadaver skin were also evalulated in vivo for the purpose of comparison. Water-vapor transmission rates and Young's moduli were measured. The degrees of adherence of the coverings to the wound were measured. Grafts which became significantly adherent (〉150 dyne/cm2) to the wound within 1 day were most successful in promoting the formation of a viable tissue bed which appeared ready to accept further grafting. The force required to remove the PCL foam laminate from a full-thickness excision wound was found to increase from 170 dyne/cm2 on the first day postgraft to 1500 dyne/cm2 by the tenth day. The force required to remove freeze-dried collagen laminate remained constant at 200 dyne/cm2 over the 10 day test period. For the heat-dried collagen laminate, a force of only 50 dyne/cm2 was required on day 1, increasing to 200 dyne/cm2 on day 6. Insensible water-loss rates of animals grafted with the laminates were found to be similar to those from animals with human cadaver skin grafts and less than that from animals with porcine skin grafts. When moistened, the laminates prepared using the freeze-dried materials were flexible and somewhat transparent permitting observation of the wound.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 15 (1977), S. 973-981 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Linear D2-m-carborane-siloxanes with one, two, and three trifluoropropyl moieties per repeat unit were prepared by the condensation reaction between bisureidosilanes and carborane disilanol. Molecular weights between 100,000 and 220,000 were obtained. Compared to fluorosilicones, the trifluoropropyl-modified carborane-siloxanes exhibited greater thermal and oxidative stability and in certain cases comparable solvent resistance. The swelling index for carborane-siloxane elastomers decreased with increasing trifluoropropyl content, although this fluorocarbon moiety did compromise the thermal stability of the carborane system.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 15 (1977), S. 2673-2684 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The zinc chloride-catalyzed polymerization of 2-vinylnaphthalene (VN) with both photoinitiation and electronitiation methods was examined. Good yields were obtained with both methods, the electroinitiated process being somewhat faster. The mechanism for polymerization initiation was investigated through a detailed comparison of the kinetics. Both initiation methods show a similar response to increasing input energy and to change in salt to monomer mole ratio. Both methods indicate formation of a ZnCl2-(2-VN)2 complex as intermediate with the formation of the species being rate-determining. These results, together with other similar investigations, are then used to deduce a mechanism that involves the formation of an electronically excited donor-acceptor complex. It is argued that in certain salt-stabilized, electron-delocalized, aromatic systems, such excitation is possible in electroinitiation.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 15 (1977), S. 1563-1571 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As part of a program to extend the range of donor-acceptor-initiated polymerization processes, the electroinitiation of 2-vinylnaphthalene in a zinc chloride-sulfolane solution has been studied. Good conversion yields of well-characterized (NMR, IR, GPC, elemental analysis) poly(vinylnaphthalene) were obtained with the process showing several mechanistic similarities to other donor-acceptor salt electropolymerization systems.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 15 (1977), S. 1555-1562 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electrochemically initiated polymerization of styrene in methylene chloride solvent with the use of platinum electrodes and tetraalkyl and -aryl group VA halides (i.e., quaternary ammonium, phosphonium, and arsonium compounds) as electrolyte has been investigated. The order of reactivity of the electrolytes with respect to polymerization rate and initiation efficiency was found to be: arsonium 〉 phosphonium 〉 ammonium. Mechanisms involving the electroreduction of the group VA quaternary halides to species capable of electroinitiating polymerization are postulated. The observed losses in solution conductivities during polymerization with the quaternary phosphonium and arsonium electrolytes indicate possible interaction between the initiating radical-ionic species and the supporting electrolyte. In an attempt to further elucidate the mechanism of initiation in these systems, a separate series of experiments, employing the nonpolymerizing monomer, 1,1-diphenylethylene, has been carried out.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 15 (1977), S. 399-405 
    ISSN: 0360-6384
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2016-06-07
    Description: Automated instruments were installed on a commercial B-747 aircraft, during the program, to obtain baseline data and to monitor key atmospheric constituents associated with emissions of aircraft engines in order to determine if aircraft are contributing to pollution of the upper atmosphere. Data thus acquired on a global basis over the commercial air routes for 5 to 10 years will be analyzed. Ozone measurements in the 29,000 to 45,000 foot altitude were expanded over what has been available from ozonesondes. Limited aerosol composition measurements from filter samples show low levels of sulfates and nitrates in the upper troposphere. Recently installed instruments for measurement of carbon monoxide and condensation nuclei are beginning to return data.
    Keywords: AIRCRAFT PROPULSION AND POWER
    Type: Aircraft Eng. Emissions; p 323-355
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-13
    Description: The results of a program of experimental and analytical research in casing treatments over axial compressor rotor blade tips are presented. Circumferential groove, axial-skewed slot and blade angle slot treatments were tested at low speeds. With the circumferential groove treatment the stalling flow was reduced 5.8% at negligible efficiency sacrifice. The axial-skewed slot treatment improved the stalling flow by 15.3%; 1.8 points in peak efficiency were sacrificed. The blade angle slot treatment improved the stalling flow by 15.0%; 1.4 points in peak efficiency were sacrificed. The favorable stalling flow situations correlated well with observations of higher-than-normal surface pressures on the rotor blade pressure surfaces in the tip region, and with increased maximum diffusions on the suction surfaces. Annulus wall pressure gradients, especially in the 50 to 75% chord region, are also increased and blade surface pressure loadings are shifted toward the trailing edge for treated configurations.
    Keywords: AIRCRAFT PROPULSION AND POWER
    Type: ASME PAPER 75-GT-60 , American Society of Mechanical Engineers, Gas Turbine Conference and Products Show; Mar 02, 1975 - Mar 06, 1975; Houston, TX
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 16 (1977), S. 1015-1031 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An electron microscope study of collagen fibrils from fixed tail tendons of rats has revealed that from some time shortly after birth until maturity, the fibril diameters have a bimodal distribution. The “two” types of fibril are indistinguishable in both transverse and longitudinal section. Unfixed specimens of eight-week-old-tail tendon showed a similar bimodal distribution of diameters though the positions of the peak values compared to fixed specimens of an eight-week-old-tail tendon were shifted upwards by about 30%. It has also been shown quantitatively that the polar collagen fibrils are directed randomly “up” and “down” with respect to their neighbors. Whilst it has been suggested by others that anastomosis is a feature of collagen structure, the results presented here do not support this hypothesis. Fibrillar units ∼ 140 Å in diameter have been observed and the possibilities that these are elastic fibers or the breakdown products of collagen fibrils have been considered.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 14 (1975), S. 633-640 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two kinds of errors are found in protein models made with the tool of Rubin and Richardson. Global errors result from the accumulation of many errors too small to localize, while local errors are assignable to particular bends in the model. We here locate the sources of local errors, and show how to minimize both kinds of errors.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...