ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • LUNAR AND PLANETARY EXPLORATION  (178)
  • Analytical Chemistry and Spectroscopy  (156)
  • 1980-1984  (276)
  • 1970-1974  (58)
  • 1980  (276)
  • 1973  (58)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
  • 1980-1984  (276)
  • 1970-1974  (58)
Jahr
  • 1
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatographic mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 9 (1980), S. 230-238 
    ISSN: 0377-0486
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: The IR spectra (1400 cm-1 to 160 cm-1) of the gases at ambient temperature and the Raman spectra (below 1400 cm-1) of the liquids near -196°C are reported for CF3OF and CF3OCl. All fundamentals are assigned under Cs symmetry and the results of a normal coordinate analysis are presented. The assignments of Smardzewski and Fox are adopted with one exception for both CF3OF and CF3OCl: the CF3 rock of A″ symmetry is assigned near 430 cm-1 and the two bands between 200 cm-1 and 300 cm-1 are assigned to an A′ fundamental, involving CF3 rocking and COX bending and a Δν=2 transition in the CF3 torsion. An extra band at 548 cm-1 in the Raman spectrum of liquid CF3 COl near -196°C is assigned to a CF3OCl⃛Cl2 complex. The values of the force constants d(OX) for CF3OX molecules are suggested to be near those for X2O molecules. More than half the normal modes of A′ symmetry show extensive mixing of symmetry coordinates. In some of these cases the symmetry coordinate for which the normal mode is named is the largest but not the dominant contributor to the potential energy distribution, while in others this symmetry coordinate is not even the largest contributor to the potential energy distribution. No normal modes of A′ symmetry are present in which ν(CO), δs(CF3), δ(COX), or δ(CF3) symmetry coordinates are dominant, and the mode conventionally labeled as v(CO) should be labeled as νs(CF3). For the remaining A′ normal modes and all the A″ normal modes, the symmetry coordinate for which the normal mode is named is dominant in the potential energy distribution.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Publikationsdatum: 2011-08-17
    Beschreibung: The Ames Research Center Pioneer 11 plasma analyzer experiment provided measurements of the solar wind interaction with Saturn and the character of the plasma environment within Saturn's magnetosphere. It is shown that Saturn has a detached bow shock wave and magnetopause quite similar to those at earth and Jupiter. The scale size of the interaction region for Saturn is roughly one-third that at Jupiter, but Saturn's magnetosphere is equally responsive to changes in the solar wind dynamic pressure. Saturn's outer magnetosphere is inflated, as evidenced by the observation of large fluxes of corotating plasma. It is postulated that Saturn's magnetosphere may undergo a large expansion when the solar wind pressure is greatly diminished by the presence of Jupiter's extended magnetospheric tail when the two planets are approximately aligned along the same solar radial vector.
    Schlagwort(e): LUNAR AND PLANETARY EXPLORATION
    Materialart: Science; 207; Jan. 25
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Publikationsdatum: 2019-06-27
    Beschreibung: Observations by the plasma wave receivers on Voyagers 1 and 2 show that a wide variety of electrostatic waves are present within the Jovian magnetosphere and that the Jovian electrostatic waves are for the most part very similar to those observed in the terrestrial magnetosphere. Bands of emission near the upper hybrid resonance frequency in the dayside outer magnetosphere are detected between higher harmonics of the electron gyrofrequency. Inside of about 23 Jupiter radii, electron cyclotron harmonic emissions appear to be durable features of the inner Jovian magnetosphere and are extremely well confined to the Jovian magnetic equator. The cyclotron emissions extend from just above the local electron gyrofrequency to the upper hybrid resonance frequency.
    Schlagwort(e): LUNAR AND PLANETARY EXPLORATION
    Materialart: Geophysical Research Letters; 7; Jan. 198
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Publikationsdatum: 2019-06-28
    Beschreibung: The results of the Pioneer Venus orbiter radiometric temperature-sounding experiment are presented with examples of each of the primary data products. The measured temperature field is used to model the dynamics of the middle atmosphere from 60 to 140 km, and the thermal and solar fluxes are used to calculate the planetary radiation budget. The data for the diurnal variation of temperature at a given height show fairly small amplitudes up to an altitude of about 95 km, above which the day to night contrast increases rapidly with height. At the equator the dependence of temperature in the stratosphere on solar longitude is dominated by a wave number 2 solar tide with an amplitude of about 10 K. The equator to pole gradients are larger than expected, and the stratosphere is typically 15 to 20 K warmer at the pole than at the equator. The most significant discovery concerning the cloud morphology is a dipole structure consisting of two clearings in the cloud at locations straddling the pole and rotating around it every 2.7 days.
    Schlagwort(e): LUNAR AND PLANETARY EXPLORATION
    Materialart: Journal of Geophysical Research; 85; Dec. 30
    Format: text
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 528-530 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Two-phase derivatization technique ; Yeast ; Splitless injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 242-246 
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The electron impact, methane positive chemical ionization, oxygen negative chemical ionization and collision induced dissociation mass analyzed ion kinetic energy spectra of nine metabolites of di-(2-ethylhexyl)phthalate are presented. The collision induced dissociation mass analyzed ion kinetic energy spectra of selected fragment ions were useful for structural information.
    Zusätzliches Material: 2 Tab.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 381-384 
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: An improved analog four-channel selected ion recording system is described, in which major modifications permit a decrease in the dwell time to 33 ms per channel, thus minimizing the mass cycling error. Synchronization with a sinusoidal sweep voltage superimposed on the normal accelerating voltage (8 kV) enables two channels to be monitored simultaneously in real time and each mass to be recorded continuously. These improvements allow measurement of ion current ratios with a precision of 0.2% over a wide dynamic range, permitting accurate determination of isotopic enrichment in biomedical assays even when this enrichment is derived from a single label. Use of the system is illustrated by the analysis of palmitate turnover in dogs (using [1 - 13C] palmitic acid) with an average standard deviation corresponding to the detection of 0.04% excess of [1 - 13C] palmitate.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    ISSN: 1052-9306
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Gas chromatography using a short packed column (45 cm, 0.2 cm i.d., 2% OV-101 on Gas-Chrom Q) with mass spectrometric detection in the selected ion monitoring mode has been found satisfactory for the analysis of lower as well as higher polybrominated biphenyls. Acceptable sensitivity (〈1 ng) may be achieved for this method by focusing selectively at either the low (m/z 20-600) or the high (m/z 600-1000) range of the quadrupole filter (low range for mono- through hexabromobiphenyl, high range for hexa- through decabromobiphenyl). A tuning technique has been developed for low range and high range polybrominated biphenyls using the ion abundances of perfluorotributylamine as a standard. Standard ions for the quantitation of mono- through decabromobiphenyls were selected and validated. The technique was applied to the analysis of a variety of environmental samples.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...