ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (624)
  • ASTROPHYSICS  (280)
  • 1980-1984  (757)
  • 1970-1974  (147)
  • 1940-1944
  • 1982  (393)
  • 1980  (364)
  • 1970  (147)
Collection
Publisher
Years
  • 1980-1984  (757)
  • 1970-1974  (147)
  • 1940-1944
Year
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 4 (1970), S. 145-187 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The influences of the conditioning treatments, surface topography, and crystal structure of carbonaceous surfaces on their ability to sorb heparin and their in vivo compatibility with blood were investigated. The results of the sorption studies indicated that the adsorption of heparin on the surfaces of turbostratic and graphitic materials is not crystallographically selective and that the amount adsorbed on relatively smooth surfaces is near the amount expected for monolayer formation. Although the adsorption of heparin on relatively smooth carbon surfaces is not influenced by the presence of benzalkonium chloride, the sorption of heparin in porous carbons can be greatly increased by a pretreatment with benzalkonium chloride. This increase was found to be due to the formation and entrapment of the insoluble heparin-benzalkonium complex in the accessible porosity. Since the heparin sorptions in Dag-154 coatings were found to be enhanced by a pretreatment with benzalkonium chloride, it was inferred that these coatings contain accessible porosity and that their initial thromboresistance depends on the formation of the benzalkonium-heparin complex in pores. In vivo tests showed that polished and outgassed, impermeable isotropic carbons deposited at low temperatures were significantly thromboresistant without the exogenous application of heparin. There was no relationship between the amount of heparin sorbed on these materials and their compatibility with blood. Polishing, for example, which reduced heparin sorption, enhanced the thromboresistance of these carbons, and while chemisorption of oxygen markedly reduced their thromboresistance, it did not influence the amount of heparin that could be sorbed. Although the heparin-benzalkonium complex sorbed in a porous carbon conferred excellent thromoboresistance in a 2-hr test, the long-tern (14-day) compatibility was not as good as for carbon surfaces that were deposited at low temperatures and then polished and outgassed prior to implanting. In vivo tests of HTI carbon structures and annealed LTI carbons indicate that the blood compatibility of a turbostratic carbon is not significantly dependent on crystallite size, Le. Limited tests of surfaces that had a preponderance of c-faces oriented parallel to the blood-carbon interface at the surface suggest that orientations of this sort are better than others.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 2 (1980), S. 5-10 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Mean free paths for inelastic scattering (λ) of low energy electrons in poly(methylmethacrylate) (PMMA) have been determined by measuring Al Kα excited C 1s and Si 2s photoelectron signal intensities as a function of ellipsometrically determined thicknesses of PMMA overlayers on silicon substrates. The λ values obtained are 29 ± 4 Å for 1196 eV electrons and 33 ± 5 Å for 1328 eV electrons. These data are necessary for the quantitative analysis of the surface region of PMMA and similar polymers by X-ray photoelectron spectroscopy (XPS). The magnitude of the λ values determined indicates that XPS measurements can provide chemical information about the surface region of polymers, such as PMMA, in the depth range of ∼6 to 100 Å. The results of this study are compared and discussed with respect to λ values determined for other organic compounds.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0721-3115
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: In the poor solvent acetone/ethanol the viscosity of a 3% solution of 12.6% N pyro nitrocellulose is found to be related to the geometric mean of the number average and weight average molecular weights. The fractional increase in the viscosity of such a solution on the addition of lead ß-resorcylate is a function only of number average molecular weight. Once calibration has been made against osmotic pressure measurements and intrinsic viscosity, both number and weight average may be measured rapidly with an accuracy which is no less than that of the osmotic pressure and intrinsic viscosity measurements themselves.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-07-13
    Keywords: ASTROPHYSICS
    Type: Extragalactic radio sources; Aug 03, 1981 - Aug 07, 1981; Albuquerque, NM
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2011-08-18
    Description: Accretion models of planet formation and the early cratering history of the solar system suggest that planet formation is accompanied by a cloud of debris resulting from accumulation and fragmentation. A rough estimate of the infrared luminosities of debris clouds is presented for comparison with measured 10-micron luminosities of young stars. New measurements of 13 F, G, and K main-sequence stars of the Ursa Major Stream, which is thought to be about 270-million years old, place constraints on the amount of debris which could be present near these stars.
    Keywords: ASTROPHYSICS
    Type: Icarus; 50; Apr. 198
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-28
    Description: Nine X-ray outbursts from the LMC have been observed with the HEAO 1 Large-Area Sky Survey Instrument. Some are shown to originate in the recurrent transient A0538-66, confirming the proposed 16 day periodicity and showing that the duration of the events can be as long as 14 days or as short as a few hours. Deviations from precise periodicity can be attributed to phase jitter or to a change in period occurring around the time of an exceptionally long outburst. Other outbursts which are irregular and consistently shorter originate in LMC X-4. A long-term light curve indicates that the LMC X-4 outbursts occur only when the source is in a high state, but are not strongly correlated with the binary phase.
    Keywords: ASTROPHYSICS
    Type: Astrophysical Journal; vol. 240
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-06-27
    Description: The paper presents a 1-10-keV survey of distance class 4, 5, and 6 Abell clusters using the HEAO 1 NRL large area survey experiment. The survey is a little less than 1/30 of the Abell catalog. Eleven clusters are identified with X-ray sources, and X-ray upper limits are provided for 60 others.
    Keywords: ASTROPHYSICS
    Type: Astrophysical Journal; vol. 235
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-06-27
    Description: The paper deals with spectrophotometric observations covering the essentially complete wavelength interval between 1.2 and 30.0 microns. The observations confirm the identification of the C3 band at 5.2 microns. They show that if SiC2 is present, the SiC1 absorption band at 5.7 microns would be obscured by C3 at a 1% spectral resolution. Silicon carbide emission at 11.5 microns exists simultaneously with C3 absorption at 5.2 microns, requiring a contribution of both species to the violet opacity of Y CVn.
    Keywords: ASTROPHYSICS
    Type: Astrophysical Journal; vol. 235
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The synthesis of poly(ε-L-lysine) is described. This is a poly(ε-amino acid) in which the ε-amino group of lysine is condensed with the α-carboxyl group to produce a chain backbone that is a variant of the usual one seen in proteins and the side chain is the α-amino group. Conformational studies of poly(ε-L-lysine) and its t-butyloxycarbonyl derivative suggest the likelihood of a chain order that is formally similar to the antiparallel pleated-sheet conformation of proteins.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...