ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 637-640 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 93-94 
    ISSN: 0935-6304
    Keywords: Chromatography Theory peak shape, mathematical basis of real standard deviation and variances are much larger than “measured” ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 164-171 
    ISSN: 0935-6304
    Keywords: Liquid chromatography, gradient technique ; Mobile phase composition programming by hardware construction ; Effluent composition curve analysis ; Numerical method for calculation and theory discussed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The theory of gradient elution under hydrostatic equilibrium is developed for the case where only one reservoir and one mixing chamber are used and where both solvents have equal densities. Given the shapes of the two vessels, effluent concentration curve equations are deduced for different mixing chamber-reservoir combinations. On the other hand, given the equation for the effluent concentration curve, the reservoir cross-sectional area, as a function of height, can be deduced when the mixing chamber has a constant cross-section. The varying cross-section of the reservoir is accomplished by inserting thin discs of different areas on top of one another inside a regular vessel of constant cross-section.Except for complicated gradients, a given gradient can be accomplished using a reservoir with a cross-sectional area which varies linearly with height. In the case of complex gradients, a reservoir having two or more linear segments becomes necessary. A numerical method is given for the calculation of the continuously varying reservoir cross-section for the exact duplication of a given gradient.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 63-67 
    ISSN: 0935-6304
    Keywords: Chromatography theory ; Elementary principles ; General equations for eff. plates in conically shaped columns ; Conical columns are more efficient than composite ones ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The theory of composite chromatographic columns has been re-examined and general equations relating their efficiency to those of individual columns were derived. The derivations were based on elementary principles without reference to the principle of variance additivity. Derived also, were general equations for the efficiency of columns with continuously varying diameters, HETP and other properties from which formulae for special cases of practical interest were deduced. An example comparing the efficiencies of two columns, one conical and the other composite was given. The calculations show clearly that the conical column is superior in efficiency for the same total length and total retention volume.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 45-47 
    ISSN: 0935-6304
    Keywords: Chromatography, theory ; Plate number calculation corrected for wide initial peaks ; Direct method of correction factor calculation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 689-697 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 193-194 
    ISSN: 0935-6304
    Keywords: Chromatography ; Theory ; Resolution equations ; Comparison and evaluation; equation (4) preferred ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 253-254 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 2 (1956), S. 477-481 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The theoretical-plate concept in chromatography has been treated on the basis of continuous flow of eluent through the plates of the column. A treatment more precise in principle than the previous treatments is presented. General elution and deposition equations have been derived and applied to special cases of practical interest. The derived formulas have the advantage of precision, generality, and simplicity.The theory was found adaptable to the treatment of gradient elution and also to the calculation of the fraction of solute which has been eluted or still-adsorbed on the column during the elution process.A method for the determination of the number of theoretical plates in a chromatographic column is also described.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...