ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (302)
  • Wiley-Blackwell  (302)
  • American Institute of Physics
  • Wiley
  • 1985-1989  (221)
  • 1970-1974  (81)
  • 1965-1969
  • 1935-1939
  • 1987  (122)
  • 1986  (99)
  • 1974  (81)
  • 1937
Collection
Publisher
  • Wiley-Blackwell  (302)
  • American Institute of Physics
  • Wiley
Years
  • 1985-1989  (221)
  • 1970-1974  (81)
  • 1965-1969
  • 1935-1939
Year
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for quantitating adenosine concentration by capillary gas chromatography-mass spectrometry-selected ion monitoring (GC-MS-SIM) has been developed and used as a reference method for evaluating a newly developed radioimmunoassay (RIA) for adenosine. Details of the GC-MS-SIM method are presented, along with the comparative results and uncertainties of both methods. General considerations in the statistical analysis of method comparison data are discussed with particular reference to studies using quantitative mass spectrometry as the standard method; the adenosine methods are used as specific examples in this discussion. Simultaneous estimation of the y-intercept and slope of the least squares regression line relating the results of the two methods using the 95% joint confidence ellipse demonstrated the absence of either constant or proportional error between the two methods. The relatively small uncertainty in the GC-MS-SIM measurements had no significant effect on the linear regression. Random error between the two methods was detected, and was estimated by the coefficient of variation in the RIA data as ten percent of the RIA value.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    X-Ray Spectrometry 16 (1987), S. 161-165 
    ISSN: 0049-8246
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Oil was chosen as a new sampl type for total reflection XRF. A thin-film sample procedure is described which requires minimal sample preparation. This involves first bringing the oil into solution with a volatile solvent, then pipetting microliter amounts on to the reflector substrate followed by evaporation of the solvent. The linear dynamic range was found to extend to at least 5000 ppm. Detection limit measurements show that minute sample quantities are necessary for optimal detection limits of nanogram amounts. A maximum sample loading is required for the best detection limits in ppm. Using an Mo or Cu X-ray tube, limits were found to be a few ppm or sub-nanogram amounts. The spectrometer was calibrated by an internal standardization method and the results of determinations on sample solutions were typically within 10% relative accuracy.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 25 (1987), S. 1040-1045 
    ISSN: 0749-1581
    Keywords: α-retinal ; α-ethyl retinoate ; α-retinol ; α-retinoic acid ; 3,4-dehydroretinal ; 3,4-dehydroretinol ; ethyl 3,4-dehydroretinoate ; 3,4-dehydroretinoic acid ; 2D heteronuclear-correlated spectroscopy ; APT ; empirical chemical shift calculations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 13C NMR assignments have been made for a series of 36 α- and 3,4-dehydroretinoids with different substituents (alcohol, ester, aldehyde and acid) and for their separated E and Z geometrical isomers. The assignments were made by using 2D heteronuclear-correlated NMR experiments. From the chemical shift data of 24 systematically related retinoids, empirical chemical shift changes due to four polar end groups (alcohol, aldehyde, carboxylic acids and esters), three chain configurations (all-E, 9Z and 13Z), and two ring substitutions (2,6,6-trimethyl-cyclohex-2-enyl and 2,6,6-trimethylcyclohexa-1,3-dienyl) were determined. All trends were found to be independent of each other, except for the dependence of the chemical shift change of the 13Z-isomers on the polar end groups. The chemical shift changes were used to predict the chemical shifts of other retinoids based on two different ring structures (2,6,6-trimethylcyclohexenyl and 4-methoxy-2,3,6-trimethylphenyl).
    Additional Material: 8 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 213-220 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermospray HPLC/MS analysis of the metabolites of arachidonic acid proved to be sensitive and specific. The compounds included were hydroxy-fatty acids (5-HETE, 12-HETE, and 15-HETE) and prostaglandins PGD2, PGE2, PGF2α, PGA2, PGA1, TXB2, and 6-Keto-PGF1α. Thermospray HPLC/MS analysis allows for simultaneous monitoring of each compound without the need for additional sample preparation or derivatization. The thermospray spectra for the metabolites exhibited [M + NH4]+ ions and fragment ions because of sequential loss of equivalents of H2O. HPLC/MS showed detection limits in the 0.5 to 5 ng range when using multiple ion detection for most of the metabolites. Post-column derivatization of these metabolites using trimethylanilinium hydroxide (TMAH) to form the methyl esters is also presented. This derivatization resulted in a gain in ion current by a factor of 3-6 for most compounds while adding potential specificity to the analysis. The thermospray spectra of the derivatives were nearly identical to the spectra of the free acid except the peaks were incremented by 14 daltons due to the methyl ester formation. The derivatization of the carboxylic acid group proved to be complete under thermospray conditions producing the maximum ion current and causing no compromise in operation of the interface.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 281-287 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fragment ion spectra obtained from collision-induced decomposition of protonated molecular ions have been used to determine amino acid sequences of several physalaemin-like peptides which were recently purified from rabbit stomach. This technique was chosen because the peptides were available in microgram quantities and were anticipated to contain pyroglutamate as the blocked N-terminal residue. Such spectra of several synthetic analogs of the naturally occurring peptides were obtained and analyzed to confirm the veracity of this peptide sequencing strategy. In addition, methyl ester derivatives of these synthetic peptides provided a crucial test for the spectral interpretation via the mass shifts thus induced.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 523-531 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Derivatization of prostaglandins and thromboxane B2 using diethyl amino ethyl chloride and diethyl amino ethyl bromide improved thermospray HPLC/MS sensitivity. The derivatization was evaluated for prostaglandin A1, A2, D2, E2, F1α, F2α, and thromboxane B2. The derivatization reaction, thermospray operating conditions, and mode of detection were optimized to produce the most intense [M + H]+ or [M - H]- ions for the derivative. Derivatization was better than 99% complete in 1 hour at 75°C. No thermal degradation of the prostaglandins was observed. Positive thermospray ionization proved the mode most sensitive, enabling detection from 10 to 300 pg of each prostaglandin under multiple ion detection. The thermospray spectra exhibited intense [M + H]+ ions for the derivative with a few fragment ions from sequential losses of water from the [M + H]+ ion. Detection of a prostaglandin metabolite in plasma over the concentration range from 3 ppm to 30 ppb was possible using this derivatization.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Bile from rats treated with acetaminophen was analyzed by direct injection onto a thermospray liquid chromatography/mass spectrometry (LC/MS) system. Two conjugated metabolites of acetaminophen were separated by the high-pressure liquid chromatographic system and analyzed by mass spectrometry. The conjugates were identified as the glutathione-acetaminophen conjugate and the glucuronide-acetaminophen conjugate by comparison of the chromatographic retention times and the mass spectra to that of the synthetic standards. No evidence of acetaminophen metabolites was observed when bile samples were subjected to direct analysis by fast atom bombardment mass spectrometry.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 39-43 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Parallel triple detection ; Diesel fuels ; Polyaromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Diesel fuels from different parts of the UK have been analyzed for polycyclic aromatic hydrocarbons (PAH), nitrogen-containing PAH, and sulfur-containing PAH using capillary column GC with simultaneous parallel triple detection. The concentrations of polyaromatic compounds (PAC) were high and showed considerable variability amongst the fuels. The PAH are mainly naphthalene, fluorene, and phenanthrene and their alkylated homologs; the PANH are mainly carbazole and its methyl derivatives; the PASH are mainly dibenzothiophene and its methyl derivatives.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 412-414 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Zanthoxylum tessmannii (Engl.) Ayafor ; Amides ; Terpene hydrocarbons ; Alkaloids ; Medicinal plant ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 525-527 
    ISSN: 0935-6304
    Keywords: Supercritical fluid chromatography, SFC ; Eluent composition gradients ; Temperature gradients ; Resolution ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...