ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Springer  (30)
  • American Institute of Physics (AIP)  (4)
  • International Union of Crystallography  (2)
  • 1995-1999  (34)
  • 1980-1984
  • 1930-1934  (2)
  • 1920-1924
  • 1995  (34)
  • 1931  (2)
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 78 (1995), S. 4784-4786 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: We have fabricated a SiO2/TiO2 high-reflectivity dielectric multilayer mirror specifically suitable for ZnSe-based vertical cavity surface-emitting lasers operating in the green-to-blue spectral region. In the fabrication process, the thickness of each layer has been precisely controlled by using an in situ optical monitoring system. A photo-pumped ZnCdSe/ZnSe/ZnSSe surface-emitting laser has also been demonstrated using the SiO2/TiO2 dielectric multilayer mirrors stacked with the ZnCdSe/ZnSe/ZnSSe structures. Cavity mode emission with a linear polarization has been observed in the direction normal to the surface at 20 K. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 101-105 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new tip height control system for noncontact scanning force microscope (SFM) utilizing the phase-lock technology is proposed. Its most extensive feature is that the system is unconditionally stable whereas the conventional control systems have difficulties in stability especially when the tip is at close proximity to the sample surface. In this new system, an oscillator using the cantilever as a mechanical resonator is used as a voltage controlled oscillator (VCO) in a phase-locked loop. Its output signal phase is locked to a high precision frequency source. The force gradient detected by the cantilever equivalently alters the VCO control voltage, which is detected as a compensational signal of the loop filter output. The phase-lock technique made it possible to reduce the tip height to an extent which was impossible with the conventional servo technology. Thus this new control technique is expected to be effective in improving the resolution of the noncontact SFM. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 67 (1995), S. 1480-1482 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Complex magnetic structures were observed on a durability tested TbFeCo magneto-optical disk. By considering the magnetic properties of the TbFeCo and the polarized microscopic image of the same region, it was concluded that those complex structures result from the decrement of the compensation temperature of the TbFeCo film at the track center. Samples that were exposed to static magnetic fields were also observed for the purpose of inspecting the changes in the coercive force of the damaged regions. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 102 (1995), S. 6208-6211 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: The absorption of radiation in the frequency range 10–80 cm−1 by 2 mol/l electrolyte solutions has been investigated. The absorption at low frequencies below 20 cm−1 is dominantly attributed to the dielectric relaxation of water dipole. At frequencies higher than 40 cm−1, resonance absorption by ion oscillation in a potential well formed by surrounding water molecules comes to contribute to the absorption. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 67 (1931), S. 808-811 
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1349-9432
    Keywords: aspherical mirror ; large aperture ; common path interferometer ; caustic waist ; computer generated hologram ; diffraction efficiency balance ; laser writer ; phase shifting
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A new CGH (computer generated hologram) common path interferometer, which can be used for testing an aspherical mirror with large aperture, is proposed. This interferometer does not have a circle of least confusion, and a spatial filter can be used effectively to stop extraneous lights so that interferograms with good contrast can be obtained. The phase shifting technique can be easily applied to the interferometer. The method of designing and making the CGH zone-plate is described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1349-9432
    Keywords: interferometry ; differential ; Newton gauge ; zone plate interferometer ; radius measurement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A new technique to measure the radius of a concave mirror is proposed, in which the radius is calculated from the difference of the two interferograms obtained before and after shifting the sample perpendicular to or along the optical axis. By comparison of these two shifting directions, it is shown that since the amount of shift can be measured accurately and the result is insensitive to the tilt during the shifting, better accuracy can be obtained by shifting the sample along the optical axis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1420-9071
    Keywords: Oviposition stimulants ; Ideopsis similis ; Danaidae ; Tylophora tanakae ; Asclepiadaceae ; (+)-isotylocrebrine ; (−)-7-demethyltylophorine ; alkaloids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract Chemicals releasing oviposition by an Asclepiadaceae feeder,Ideopsis similis, were identified from a host plant,Tylophora tanakae. A strong positive response was evoked by a methanolic extract of the plant, which proved to contain multiple stimulants. A mixture of two phenanthroindolizidine alkaloids, (+)-isotylocrebrine and (−)-7-demethyltylophorine, isolated from organic fractions, elicited significant ovipositional responses from females.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Optical review 2 (1995), S. 163-166 
    ISSN: 1349-9432
    Keywords: nonlinear filters ; image processing ; filter design method ; learning filter optimization ; mathematical morphology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A simulator to aid in the design of nonlinear image processing filters is developed. This simulator assists the filter design by determining parameters manually by trial-and-error. The method is also useful for improving the results of the learning optimization methods. An example of the application of the technique to improve a resultant filter by a learning method of a mathematical morphological filter is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0827
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The skeletal contents of insulin-like growth factor-2 (IGF-II), insulin-like growth factor binding protein-5 (IGFBP-5), and insulin-like growth factor binding protein-3 (IGFBP-3) were determined in duplicate samples of human femoral cortical bone obtained from 64 subjects (44 males and 20 females) between the ages of 20 and 64 years. The results of these quantitative measurements revealed an age-related decrease in the femoral cortical content of IGFBP-5 (r=-0.272, P=0.031) in the total population. Although the femoral cortical content of IGF-II did not show a similar decrease with age, it could be correlated to the femoral cortical content of IGFBP-5 (r=0.442, P〈0.001). In constrast, the femoral cortical content of IGFBP-3 did not decrease with age and could not be correlated to the femoral cortical contents of either IGFBP-5 or IGF-II. Comparisons of these results with previous measurements of insulin-like growth factor-1 (IGF-I) and transforming growth factor-β (TGF-β), in extracts of the same bones, showed significant cross-correlations between the femoral cortical contents of each of these growth factors and the femoral cortical contents of IGFBP-5 (r=0.625 for IGF-I versus IGFBP-5, r=0.554 for TGF-β versus IGFBP-5, P〈0.001 for each) but not IGFBP-3. Together, these data indicate average net losses of 60% and 29% of the femoral cortical contents of IGF-I and IGFBP-5, respectively, and apparent net losses (i.e., nonsignificant decreases) of 21% and 25% of the femoral cortical contents of IGF-II and TGF-β, respectively, between the third and the sixth decades (i.e., decreases from young adult values of 75.1 pmol/g of bone for IGF-I, 124.7 pmol/g of bone for IGF-II, 0.71 pmol/g of bone for TGF-β, 115.6 pmol/g of bone for IGFBP-5, and 26.2 pmol/g of bone for IGFBP-3).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...