ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (1,199)
  • Analytical Chemistry and Spectroscopy  (447)
  • Organic Chemistry  (141)
  • Genetics  (23)
  • crystal structure
  • Wiley-Blackwell  (1,826)
  • 1990-1994  (1,074)
  • 1980-1984  (751)
  • 1915-1919
  • 1890-1899  (1)
  • 1994  (574)
  • 1991  (500)
  • 1982  (372)
  • 1981  (379)
  • 1940
  • 1916
  • 1895  (1)
Collection
Keywords
Publisher
Years
  • 1990-1994  (1,074)
  • 1980-1984  (751)
  • 1915-1919
  • 1890-1899  (1)
  • 1940-1944  (3)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 42 (1991), S. 863-866 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Nascent high-molecular-weight (UHMW) polyethylene (PE) samples of different origins show a rather high crystallinity of about 70-75% and contain both a major portion of orthorhombic extended chain crystallites and a minor portion of triclinic crystallites. The triclinic content is greater the higher the molecular weight of the sample and the higher the activity of the used catalyser. A melting / recooling treatment results in a reduction of crystallinity by about 15-25% and disappearance of the triclinic phase. Further, an irreversible conversion of nascent orthorhombic extended chain crystallites to orthorhombic folded chain crystallites of increased lateral dimensions and crystalline perfections takes place during the melting / recooling treatment. The results are compared to those obtained for lower-molecular-weight PE samples and for high-strength / modulus PE fibers of different origins.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The need for alternatives to autogenous bone grafts is widely recognized. This study compared the torsional strength of canine femora 1 year after grafting with one of three forms of a collagen/hydroxyapatite/tricalcium phosphate bone grafting material (COLLAGRAFT15), autogenous bone, or no graft. The groups were compared to each other and to the unoperated contralateral femora. Results of torsional testing were evaluated for torsional strength, torsional displacement, total energy to fracture and White fracture mode. Data analysis showed lower torsional strength of the operated vs. unoperated femora with the exception of morsellized COLLAGRAFT15 material, which had higher strength. However, the only difference in the operated groups was that the morsellized COLLAGRAFT15 had greater strength than several groups including the autogenous bone group. There was no difference found in angular displacement between any of the groups. However, there was a difference in the energy to fracture in both strip forms of the COLLAGRAFT15. The final conclusion is that in this model, grafting with COLLAGRAFT15 provided torsional properties at one year postoperatively at least equivalent to autogenous bone. © 1994 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 42 (1991), S. 2483-2488 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Bilirubin, a bile pigment, was studied for its extent of adsorption on substituted aminechloromethyl polystyrene by UV spectrophotometry. By performing simple displacement reactions on chloromethyl polystyrene with secondary and tertiary amines, the amount of charge density and steric factor on substituted nitrogen atom have been varied. Adsorption isotherms of bilirubin at 0°C by different amine-chloromethyl polystyrene homologs suggest the existence of electrostatic interaction of polymeric resin with bilirubin moiety. Results of adsorption of bilirubin to polymeric resin have shown that the extent of adsorption of bilirubin depends on the unit charge, and on the structure of the substituted amine-chloromethyl polystyrene. The effects of porosity of resin on bilirubin adsorption have also been discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 26 (1981), S. 509-519 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The deterioration of polyolefin, poly(ethylene terephthalate), and polyamide films under soil burial conditions extending up to 32 months has been investigated. Based on changes in their elongation at break, the films can be ranked in order of increasing sensitivity to degradation: Polyester ≃ polypropylene 〈 low-density polyethylene ≃ high-density polyethylene 〈 nylon 6.6. The degraded nylon 6.6 and polyethylene films were characterized by infrared and luminescence spectroscopy and scanning electron microscopy, as well as by wet analysis for hydroperoxides. From a comparison with the well-known oxidative sensitivity of nylon 6.6 in oxygenated water at slightly elevated temperatures, the rapid deterioration of nylon 6.6 film during soil burial was also concluded to be an oxidative process. The somewhat smaller, but significant, embrittlement of the polyethylenes studied could not be simply explained by thermal oxidation (with only trace oxidation products detectable) or microbiological attack (deterioration being unaffected by surface activation to enhance wettability).
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 28 (1994), S. 405-405 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 16 (1982), S. 381-398 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypotheses can explain the apparent conflict between the platelet adhesion data and the coagulation time data.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Secondary ion mass spectrometry has been used to identify the presence of Cu contamination on undoped semiinsulating GaAs wafer surfaces following polishing under certain conditions. The presence of a contaminating species on the wafer surface is indicated by the influence of pre-etch treatments on electrical measurements performed on heat-treated wafers, with and without Si implants. The identification of Cu as a contaminant is confirmed by photoluminescence measurements. With the appropriate wafer preparation process, the level of Cu contamination is below the SIMS detection limit of 〈1 × 1016 atoms cm-3.In the SIMS analysis of the surface-contaminated wafers, the Cu depth profile shape was dependent on the primary beam bombardment energy, suggesting a chemical segregation of Cu out of the altered layer, a redistribution that is known to occur in Si.To quantify the surface concentration of Cu, GaAs wafers were deliberately contaminated with Cu, heat treated and analysed with glow discharge mass spectrometry and SIMS to provide a cross-calibration.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 19 (1981), S. 2817-2834 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Thermal degradation behavior of poly(1,3-phenylene isophthalamide) and poly(chloro-2,4-phenylene isophthalamide) was investigated with the aid of some appropriate model compounds. The pyrolysis products of these materials were identified by gas chromatography (GC), gas chromatography/Fourier transform infrared spectroscopy (GC/FT-IR), and gas chromatography/mass spectrometry (GC/MS). The residual chars were characterized by IR spectroscopy. Thermogravimetric analysis (TGA) was applied to study the effect of end-group concentration on the degradation characteristics of the two polyamides. Kinetic parameters that describe the thermal degradation of the polyamides were also evaluated by TGA. The results of this investigation suggest that the thermal decomposition of these aromatic polyamides involves homolytic as well as hydrolytic cleavages of the amide units.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 16 (1981), S. 123-125 
    ISSN: 0030-4921
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two NQR lines were observed for 35Cl in 2,5-dichloro-4-nitroaniline at room temperature, using a self-quenched super-regenerative spectrometer. Analysis of the Zeeman effect on the two lines using a cylindrical single crystal reveals that the crystal belongs to the monoclinic system. The principal field gradient Z axes enclose an angle of 35° and 28° in the cases of the low and high frequency resonance lines, respectively. The b axis is parallel to 81°, 280°. The unit cell contains either two or a multiple of two molecules. The molecules in the crystal can be arranged into two sets, with the molecular planes in each set being parallel among each other. The angle subtended between the two planes is 159° and each of the planes is inclined to the b axis at an angle of 79.5°. There is an in-plane bending of the two C—Cl bonds by 5.5°. The ionic, single bond and double bond characters of the C—Cl bonds for both chlorines are almost equal, and are in the ratio 24:73:3.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0749-503X
    Keywords: Hansenula ; haemoglobin ; integration ; continuous culture ; Life and Medical Sciences ; Genetics
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: Recombinant human haemoglobin A (rHbA) was produced by a leucine-requiring strain of Hansenula polymorpha which had been transformed with an integration vector containing the Saccharomyces cerevisiae LEU2 gene and cDNAs for the expression of α and β globin each driven by the H. polymorpha MOX promoter. After 40 generations in a chemostat it was found that the integrated vector had become amplified in the host strain. In some cases this led to an increase in LEU2 gene dosage, but a loss of globin expression cassettes. In other cases the globin gene dosage also increased. These changes coincided with an increase in rHbA production in the culture, which was reversed when the dilution rate was increased. Isolates from a chemostat culture producing elevated levels of rHbA were grown in fed-batch fermentations, resulting in higher productivities than when inoculated with the parent strain. The rHbA produced was purified and characterized. Oxygen binding studies and electrospray mass spectrometry showed that the rHbA had been processed and assembled correctly, and behaved as a fully functional co-operative tetramer.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...