ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (52)
  • Other Sources
  • Articles: DFG German National Licenses  (52)
  • Physics  (43)
  • titanium  (9)
  • Atomic, Molecular and Optical Physics
  • Wiley-Blackwell  (52)
  • 1995-1999  (52)
  • 1980-1984
  • 1998  (52)
Collection
  • Articles  (52)
  • Other Sources
Source
  • Articles: DFG German National Licenses  (52)
Publisher
Years
  • 1995-1999  (52)
  • 1980-1984
Year
  • 1
    ISSN: 0021-9304
    Keywords: implant ; titanium ; osteoblasts ; surface roughness ; 1α,25- (OH)2D3 ; differentiation ; local factor ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Surface roughness has been shown to affect differentiation and local factor production of MG63 osteoblast-like cells. This study examined whether surface roughness alters cellular response to circulating hormones such as 1α,25-(OH)2D3. Unalloyed titanium (Ti) disks were pretreated with HF/HNO3 (PT) and then were machined and acid-etched (MA). Ti disks also were sandblasted (SB), sandblasted and acid etched (CA), or plasma sprayed with Ti particles (PS). The surfaces, from smoothest to roughest, were: PT, MA, CA, SB, and PS. MG63 cells were cultured to confluence on standard tissue culture polystyrene (plastic) or the Ti surfaces and then treated for 24 h with either 10-8M or 10-7M 1α,25-(OH)2D3 or vehicle (control). Cellular response was measured by assaying cell number, cell layer alkaline phosphatase specific-activity, and the production of osteocalcin, latent (L) TGFβ, and PGE2. Alkaline phosphatase activity was affected by surface roughness; as the surface became rougher, the cells showed a significant increase in alkaline phosphatase activity. Addition of 1α,25-(OH)2D3 to the cultures caused a dose-dependent stimulation of alkaline phosphatase activity that was synergistic with the effect caused by surface roughness alone. 1α,25-(OH)2D3 also caused a synergistic increase in osteocalcin production as well as local factor (LTGFβ and PGE2) production on the rougher CA, SB, and PS surfaces, but it had no effect on the production on smooth surfaces. The inhibitory effect of surface roughness on cell number was not affected by 1α,25-(OH)2D3 except on the SB surface. 1α,25-(OH)2D3 decreased cell number, increased alkaline phosphatase activity and osteocalcin production, and had no effect on LTGFβ or PGE2 production by MG63 cells grown on tissue culture polystyrene. These data suggest that bone cell response to systemic hormones is modified by surface roughness and that surface roughness increases the responsiveness of MG63 cells to 1α,25-(OH)2D3. They also suggest that the endocrine system is actively involved in normal bone healing around implants. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 77-85, 1998.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: implant ; titanium ; osteoblasts ; prostaglandin ; indomethacin ; surface roughness ; 1α,25-(OH)2D3 ; differentiation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Surface roughness affects proliferation, differentiation (alkaline phosphatase and osteocalcin), local factor production [transforming growth factor (TGFβ) and prostaglandin E2 (PGE2)], and response to 1,25-(OH)2D3 (1,25) of MG63 osteoblast-like cells. In this study, we examined whether the effect of surface roughness on MG63 cells is mediated by prostaglandins produced by the cells. Unalloyed titanium (Ti) disks were pretreated with HF/HNO3 (PT) and then machined and acid-etched (MA). Disks were also coarse grit-sandblasted (SB), coarse grit-sandblasted and acid-etched (CA), or plasma-sprayed with Ti particles (PS). The surfaces, from smoothest to roughest, were PT, MA, CA, SB, and PS. MG63 cells were cultured to confluence on the Ti disks in the presence or absence of 10-7M indomethacin (Indo), a specific inhibitor of cyclooxygenase activity, resulting in decreased prostaglandin production. When the cells reached confluence, cell number, cell layer alkaline phosphatase specific activity (ALPase), and osteocalcin (OC) and latent TGFβ (LTGFβ) production were determined. In addition, confluent cultures which had been grown in the absence of Indo were exposed to 10-7M 1,25, 10-7M Indo, or a combination of the two for 24 h. On the rougher surfaces, cell number was decreased and ALPase, OC, and LTGFβ were increased. When indomethacin was present throughout the culture period, the effect of surface roughness on cell number, OC, and LTGFβ was abolished. ALPase was reduced, but surface roughness-dependent effects were still observed. Addition of indomethacin to confluent cultures for 24 h had no effect on any of the parameters examined, with one exception: Cells cultured on MA surfaces exhibited a more differentiated phenotype. 1,25 increased all parameters examined on SB, CA, and PS surfaces. When indomethacin was added with 1,25, the 1,25-dependent effects on cell number and OC and LTGFβ production were abolished; however, ALPase was unaffected. This indicates that bone cell response to systemic hormones may be modified by implant surface roughness. This effect may be mediated, at least in part, by prostaglandins produced by the same cells. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 41, 489-496, 1998.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 65-73 
    ISSN: 0887-6266
    Keywords: poly(ether ether ketone) (PEEK) ; poly(ether ketone ketone) (PEKK) ; solvent-induced crystallization ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The relationship between semicrystalline morphology and glass transition temperature has been investigated for solvent-crystallized poly(ether ether ketone) (PEEK) and poly(ether ketone ketone) (PEKK). Solvent-crystallized specimens of both PEEK and PEKK displayed a sizeable positive offset in Tg compared to quenched amorphous specimens as well as thermally crystallized specimens of comparable bulk crystallinity; the offset in Tg for the crystallized samples reflected the degree of constraint imposed on the amorphous segments by the crystallites. Small-angle X-ray scattering studies revealed markedly smaller crystal long periods (d) for the solvent-crystallized specimens compared to samples prepared by direct cold crystallization. The strong inverse correlation observed between Tg and interlamellar amorphous thickness (lA) based on a simple two-phase model was in excellent agreement with data reported previously for PEEK, and indicated the existence of a unique relationship between glass transition temperature and morphology in these poly(aryl ether ketones) over a wider range of sample preparation history and lamellar structure than was previously reported. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 65-73, 1998
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 3115-3125 
    ISSN: 0887-6266
    Keywords: interfacial thickness ; PPO ; SAN ; SMA ; neutron reflectivity NR ; binary interaction energies ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Estimates for the thickness of the interface between poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) and copolymers of styrene-acrylonitrile (SAN) and styrene-maleic anhydride (SMA) based on the theory of Helfand and Tagami are compared to neutron reflectivity (NR) measurements. Good agreement is found between the NR measurements and theoretical predictions that make use of a mean field binary interaction model and previously reported binary interaction energies. The techniques outlined in this work may be used to understand relationships between the mechanical properties of multiphase polymer blends and the fundamental thermodynamics of polymer interactions. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 3115-3125, 1998
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 1889-1899 
    ISSN: 0887-6266
    Keywords: polymer ; blend ; cocontinuity ; phase inversion ; interface ; morphology ; elasticity ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: In this work the level of continuity and cocontinuity for blends of HDPE/PS prepared on a twin-screw extruder have been studied by both morphology and dissolution studies. Addition of SEBS as an interfacial modifier results in a shift of the percolation threshold for dispersed PS to higher concentrations. The region of phase inversion, however, is maintained at 70% PS. The shift in the percolation threshold to higher values is related to reduced elongation of the PS dispersed phase after interfacial compatibilization. These results indicate that an interfacial modifier significantly influences percolation phenomena without shifting the region of phase inversion. Models based on viscosity ratio have failed to predict the region of phase inversion in this study. Elastic effects are shown to be able to describe the basic tendencies. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 1889-1899, 1998
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 373-381 
    ISSN: 0887-6266
    Keywords: pressure-sensitive adhesive ; PSA ; tackifier ; tack adhesion ; polyisoprene ; poly(ethylene-propylene) ; pulsed gradient spin echo-nuclear magnetic resonance ; PGSE-NMR ; diffusion ; n-butyl ester of abietic acid ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A detailed study of the mobility of a tackifying resin in a pressure-sensitive adhesive (PSA) has been done for the first time. The objective of this work is to relate changes in adhesive performance with tackifier loading to tackifier mobility. Tackifiers are low-molecular weight resins that improve the overall performance of PSAs. They increase the adhesive tack or the ability to form a bond of measurable strength after brief contact under slight applied pressure. In this study the diffusion of n-butyl ester of abietic acid (n-BEAA) in either polyisoprene (PI) (Mw = 195,000 Mw/Mn ∼ 1.05) or poly(ethylene-propylene) (PEP) (Mw = 40,000 Mw/Mn ∼ 2.30) was measured by Pulsed Gradient Spin Echo-Nuclear Magnetic Resonance (PGSE-NMR) as a function of both tackifier concentration and temperature. The concentration dependence of the tackifier's diffusion coefficient was weak for both systems. The weak variation in mobility with composition for the PI/n-BEAA system was consistent with that system's weak variation in tack with composition. On the other hand, blends of PEP/n-BEAA showed only modest variation in mobility, even though these adhesive systems showed appreciable enhancement of tack at intermediate compositions. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 373-381, 1998
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 999-1004 
    ISSN: 0887-6266
    Keywords: latex ; polystyrene ; luminescence ; particle ; micron-diameter ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: A technique for rapid determination of the presence of polystyrene in individual micron-diameter polymer particles of mixed composition is presented. This technique is based upon observation of visible emission from conjugated regions of the polymer backbone, generated photochemically, while the particle is held in an optical trap. Particle emission characteristics are dependent upon particle size and suspending solvent. Emission spectra are provided for single component polystyrene particles and mixed polymer particles containing poly(methyl methacrylate), poly(N-vinyl pyrrolidone), and polystyrene. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 999-1004, 1998
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 1167-1189 
    ISSN: 0887-6266
    Keywords: poly(dimethylsiloxane) ; silica ; hydrolysis ; condensation ; gelation ; composites ; filled elastomers ; stress-strain isotherms ; reinforcement ; X-ray scattering ; neutron scattering ; fractal geometry ; disordered systems ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Various synthetic protocols were used to prepare several classes of polysiloxane-silica filler systems. The structures of these fillers and their interactions with the polysiloxane matrices were studied using small-angle X-ray and neutron scattering. In addition, the mechanical properties of the composites were characterized using equilibrium stress-strain isotherms in elongation. The results indicated that manipulation of the chemical reactions used to generate the filler can lead to a wide range of complex structures and unusual properties. Some of the observed mechanical properties were correlated with information on the composite structures and on elastomer-filler interactions. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 1167-1189, 1998
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0887-6266
    Keywords: poly(methylphenylsiloxane) ; poly(dimethylsiloxane) ; titania ; silica ; composites ; reinforced elastomers ; morphology ; stress-strain isotherms ; scattering intensities ; differential scanning calorimetry ; transmission electron microscopy ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The work reported in the preceding article in this series is extended by consideration of polysiloxane-ceramic composites based on atactic poly(methylphenylsiloxane) (PMPS) elastomers instead of poly(dimethylsiloxane). The former is noncrystallizable because of its stereochemically irregular structure, while the latter is crystallizable. In addition, some composites were prepared by the in situ precipitation of titania instead of silica. The resulting materials were characterized using differential scanning calorimetry, equilibrium stress-strain measurements in elongation, small-angle neutron scattering, and transmission electron microscopy. The moduli of the PMPS elastomers were found to increase significantly with increase in amount of either type of filler, with reinforcing upturns at high elongation in the case of the silica. Because the PMPS elastomers were amorphous, it is obvious that strain-induced crystallization is not required for these upturns in modulus. Titania did not give as good reinforcement as did silica, at least in the case of PMPS. Differences in interactions between the polymer and the two fillers are obviously important in this regard, but differences in particle morphology probably also contribute. Specifically, the titania “particles” were significantly larger than the silica particles when observed in TEM, and appeared to be much more porous. The actual domain size as measured by scattering, however, was only approximately 5% larger. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 1191-1200, 1998
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 2275-2290 
    ISSN: 0887-6266
    Keywords: associative polymers ; rheology ; thickening ; hydrophobic ; Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The rheological properties of hydrophobic alkali-soluble associative polymers (HASE) were studied using controlled rate (Mettler LS40) and controlled stress (TA CSL 500) rheometers. The effects of pH and polymer concentrations on the rheological properties of three HASE model polymer systems (i.e., HASE 5141, 5134, and 5142, with a degree of ethoxylation of 2.5, 10, and 40 mol, respectively) and a reference polymer without associative hydrophobes (MAAEA) were examined. As the pH is increased by addition of ammonia to greater than 5-6, the carboxyl groups ionize to carboxylate ions and the polymers become water soluble. The HASE polymers thicken mainly by hydrophobic association. Viscosity can increase by two to three orders of magnitude as pH is raised to 9. The degree of ethoxylation in the macromonomer controls the nature of the hydrophobic association junctions by altering the flexibility and hydrophobicity of the macromonomer. Optimum thickening efficiency is observed in the system with approximately 10 mol of an ethylene-oxide spacer between the polymer backbone and the macromonomer. Viscoelastic study shows that the maximum thickening efficiency also corresponds to the dominant elastic property observed in the system with 10 mol of EO. All the model systems except the control system without hydrophobe exhibit strain thickening of the viscous and elastic components. © 1998 John Wiley & Sons, Inc. J. Polym. Sci. B Polym. Phys. 36: 2275-2290, 1998
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...