ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (3,219)
  • Articles: DFG German National Licenses  (3,219)
  • Springer  (3,153)
  • Annual Reviews  (66)
  • Oxford University Press
  • 1980-1984  (3,219)
  • 1975-1979
  • 1983  (3,219)
Collection
  • Articles  (3,219)
Source
Years
  • 1980-1984  (3,219)
  • 1975-1979
Year
  • 1
    ISSN: 1573-0662
    Keywords: Tropospheric ozone ; ozone precursors ; photochemistry ; nitrogen oxides ; rural ozone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Geosciences
    Notes: Abstract The seasonal and diurnal variations of ozone mixing ratios have been observed at Niwot Ridge. Colorado. The ozone mixing ratios have been correlated with the NO x (NO+NO2) mixing ratios measured concurrently at the site. The seasonal and diurnal variations in O3 can be reasonably well understood by considering photochemistry and transport. In the winter there is no apparent systematic diurnal variation in the O3 mixing ratio because there is little diurnal change of transport and a slow photochemistry. In the summer, the O3 levels at the site are suppressed at night due to the presence of a nocturnal inversion layer that isolated ozone near the surface, where it is destroyed. Ozone is observed to increase in the summer during the day. The increases in ozone correlate with increasing NO x levels, as well as with the levels of other compounds of anthropogenic origin. We interpret this correlation as in-situ or in-transit photochemical production of ozone from these precursors that are transported to our site. The levels of ozone recorded approach 100 ppbv at NO x mixing ratios of approximately 3 ppbv. Calculations made using a simple clean tropospheric chemical model are consistent with the NO x -related trend observed for the daytime ozone mixing ratio. However, the chemistry, which does not include nonmethane hydrocarbon photochemistry, underestimates the observed O3 production.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have studied the reactionspp→ppπ+π-,K + p→K + pπ +π−π, π+ p→ π+,pπ+π− and π− p →π+π− at 147 GeV/c using the 30-inch Fermilab hybrid system. All four reactions were detected with the same apparatus and analyzed in the same way. The energy dependence of the channel cross section was found to beAp −0.6+B for thepp reaction andAp −1+B for the other three. About 90% of the cross section at 147 GeV/c can be accounted for by either beam or target diffraction. Some of the remaining cross section may come from double Pomeron exchange reactions which we tried to isolate. We have tested the hypothesis of a factorizable Pomeron and our data indicates a violation of this hypothesis. We show that the 3π mass enhancement in the mass region 1.2–1.4 GeV is diffractively produced in the π± beam reactions. Fourprong, four-constraint and six-prong, four-constraint cross sections are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 21 (1983), S. 657-663 
    ISSN: 1741-0444
    Keywords: Biomechanical stability ; External fixation ; Pelvic fractures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A laboratory cadaveric model, developed previously for the study of currently employed external fixation devices used for unstable pelvic fractures was used to evaluate rigidity improvements associated with a number of fixation design innovations. Based on quasistatic shearing displacements measured at the sacro-iliac joint and symphysis pubis disruption sites, otherwise identical anterior frameworks constructed on 5 mm fixation halfpins, rather than upon standard 4 mm halfpins, were able to sustain markedly (58% to 210%) greater loadings. A new and very simple traingular framework was designed and constructed for which the fixation rigidity was found to rival that of much more complex and cumbersome double anterior frames. When used as the posterior component of combined anterior/posterior fixation systems, a new double cobra-type (internal) plate allowed the injury model pelvises to sustain near-physiological load levels. A pair of dynamic compression plates attached across a disrupted symphysis pubis was found to be a biomechanically acceptable substitute for an anterior external fixator.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1572-946X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We present photoelectric photometry of this bright long-period RS CVn binary and use it, along with earlier photometry, to derive the photometric period and discuss the changing light curve shape. The best ephemeris for times of minimum light is 2443829.2+53.d95E. Because times of minimum and maximum extending back to those of Calder in 1933–37 can be phased together properly, the principal dark region must have maintained its identify for almost 50 yr. Over the last five years the brightness range has been 3 m .70〈V〈4 m .05. During 1980–81 shallow secondary minima developed at phases where maxima occurred in previous years. λ And remains the only wellestablished case of non synchronous rotation among the known RS CVn binaries.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1572-946X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Five years of photoelectric photometry of this bright K1 III RS CVn binary has been obtained at thirteen different observatories. Except for one year, the light curve has shown two minima, separated by roughly a half cycle. At the epoch of discovery (1977.2) one minimum was shallower but as of 1980.2 the two became comparable in depth. During the 1979–80 season the light curve changed shape rapidly, the shallower minimum becoming as deep as the other within about 80 days or perhaps less. Times of both minima can be fit with a photometric period of 19 d .423, which is 0.9% shorter than the 19 d .603 orbital period. The overall brightness range during the five years has been 4 m .13〈V〈4 m .29.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have observed Cerenkov light, well below threshold, in an integrating Cerenkov counter used to determine particle composition of the secondary hadron beam, which is the source of Fermilab narrow-band neutrinos. The phenomenon can be understood in terms of diffraction effects in a finite length counter caused by radiation emitted by particles traversing the counter even when it is evacuated. At zero pressure, the light can be considered as transition radiation produced when particles enter and leave the counter. A standard Cerenkov diffraction formula describes both the normal Cerenkov radiation and the light emitted below Cerenkov threshold.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Cross sections for the reactionse + e −→e + e − (Bhabha scattering) ande + e −→γγ are measured for center-of-mass (c.m.) energies $$\sqrt s $$ between 12.0 and 34.6 GeV. The results agree with the predictions of Quantum Electrodynamics (QED) and the cut-off parameters are determined. From Bhabha scattering at the highest energy, $$\left\langle {\sqrt s } \right\rangle = 34.6 GeV$$ , the 1 δ limits 0.12〈sin2 ϑ w 〈0.38 are obtained for the weak mixing angle. The higher order (α3) QED processese + e −→e + e −γ ande + e −→γγγ are also studied and are found to agree with the α3 QED predictions. A search for excited electrons is carried out by investigating the (e ±γ) invariant mass distribution in the reactione + e −→e + e −γ.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1434-6052
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The mean charged multiplicity as well as its distribution has been measured as a function of c.m. energy in the reactione + e −→hadrons. Fragmentation models are compared with the data. After applying radiative corrections the mean charged multiplicity is measured to be 8.4±0.3±0.6 at 12 GeV, 13.1±0.3±0.6 at 30 GeV and 13.6±0.3±0.6 at 35 GeV. The ratio of mean charged multiplicity to the dispersion (〈N ch〉/D ch) is almost constant in the energy range studied, indicating KNO scaling of the charged multiplicity. The inclusive differential cross sections(dσ/dx p ) shows scaling violation in the highx p region (x p 〉0.15). The absolute value of the scaling violation is consistent with the result of 2nd order QCD calculations. The production of neutral kaons has been investigated by identifying the decayK S 0 →π+π−. The production probability for a strange quark relative to that of au ord quark in the fragmentation, γ s , has been determined to be 0.27±0.03±0.05 averaged over c.m. energies from 12 to 35 GeV. Momentum spectra for neutral kaons are presented and are compared with model predictions.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1432-1041
    Keywords: cimetidine ; intravenous infusion ; pharmacokinetics ; peptic ulcer ; duration of infusion ; acute dose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The use of cimetidine administered by bolus intravenous injection to critically ill patients has been associated with serious cardiac arrhythmias, due presumably to high initial plasma concentrations. The aim of this study was to determine the range of infusion times of a single 200 mg dose of cimetidine which would avoid high initial drug concentrations while maintaining a duration of effective concentrations no less than that resulting from bolus injection. Computer simulations of both maximum plasma cimetidine concentrations and duration of effective plasma cimetidine concentrations versus duration of infusion were based on mean pharmacokinetic date from 6 peptic ulcer patients who had received cimetidine 200 mg i.v. over 5 min. The simulations indicated that to reduce maximum plasma cimetidine concentrations by at least 50%, while maintaining the duration of effective plasma concentrations, the infusion time should be at least 30 min and no longer than 4.5 h. The validity of the simulations was subsequently tested in 4 of the patients, who received cimetidine 200 mg i.v. over 30 min. The mean maximum plasma concentration for the 30 min infusion (4.57±0.53 µg/ml) was, as predicted, approximately half that corresponding to bolus administration in these patients (8.97±1.96 µg/ml). Moreover, the duration of effective concentrations for the infusion (1.43±0.28 h) was significantly greater than that for the 5 min infusion (1.21±0.31 h). We suggest that where an acute intravenous dose of cimetidine (200 mg) is indicated, it should be administered over at least 30 min rather than as a bolus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 25 (1983), S. 413-417 
    ISSN: 1432-1041
    Keywords: lidocaine ; alpha1-acid glycoprotein ; protein binding ; free fraction ; displacement ; basic drug interaction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Since little is known of the number and types of binding sites on α1-acid glycoprotein (AAG) and because drug-drug protein binding interactions often fail to fit a simple model, a study of the effect of 9 known AAG binding drugs on lidocaine free fraction (LFF) was performed. Serum was obtained from 10 healthy males, pooled and various concentrations (from 0.15 to 1 000 µg/ml) of amitriptyline, bupivacaine, chlorpromazine, disopyramide, imipramine, meperidine, nortriptyline, propranolol and quinidine were added. LFF was determined by equilibrium dialysis at an initial lidocaine concentration of 2.0 µg/ml. LFF increased from 0.30±0.019 (mean ± SD) in the absence of displacing agents to maximum values ranging from 0.59 (nortriptyline) to 0.73 (bupivacaine). Plots of LFF vs. the logarithm of displacing drug concentration yielded simple sigmoidal curves in all cases. LFF was increased 50% by an initial bupivacaine concentration of 6.0 µg/ml with all other drugs requiring more than 10 µg/ml to increase LFF to that extent. Lidocaine binding in a 4.5 g/dl albumin solution was unaffected by concentrations of quinidine, meperidine, nortriptyline and bupivacaine up to 200 µg/ml. Addition of AAG to serum reduced LFF as expected. A plot of the reciprocal of bound drug concentration vs. the reciprocal of free drug concentration in the presence and absence of quinidine suggested a competitive binding interaction. These data indicate that the binding interactions between lidocaine and the various displacing compounds are not significantly complicated by cooperative effects and that, with the possible exception of bupivacaine, displacement of lidocaine by any of these drugs is unlikely to be of clinical significance.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...