Publication Date:
2016-08-04
Description:
HL-2M is a new medium-sized tokamak with major radius of 1.78 m, minor radius of 0.65 m, and aspect ratio of 2.8 and will be finished soon. In the conceptual design, a double-pass, horizontal view, multi-channel far-infrared (FIR) laser interferometer/polarimeter system (at 432 μm) is proposed to simultaneously measure the phase change and the Faraday rotation for density and current profile reconstruction. A vertical CO 2 dispersion interferometer system (with wavelength of 10.6 μm and 5.3 μ m) is designed to measure the line density, which will mainly be used for density feedback. The performance of the system is expected to meet the requirement of the measurements on HL-2M, with phase accuracy ∼0.1°, time resolution ∼1 μ s, spatial resolution ∼7.2 cm, and density measurement range of 1 × 10 18 –1 ×10 21 m −3 .
Print ISSN:
0034-6748
Electronic ISSN:
1089-7623
Topics:
Electrical Engineering, Measurement and Control Technology
,