ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Publisher
Years
  • 1
  • 2
    Publication Date: 1940-06-01
    Print ISSN: 0372-820X
    Electronic ISSN: 1435-1536
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 1939-09-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 1939-09-01
    Print ISSN: 0026-3672
    Electronic ISSN: 1436-5073
    Topics: Chemistry and Pharmacology
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Colloid & polymer science 91 (1940), S. 287-294 
    ISSN: 1435-1536
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Notes: Zusammenfassung Die Frage nach dem Bau der Aluminiumsalze der Stearinsäure wird, unter besonderer Berücksichtigung der Hydrolysenvorgänge bei der Bildung, untersucht. Durch die Methode des Umfallens wird erstmalig ein einheitlich zusammengesetztes Aluminiumstearat erhalten. Die Verfasser unterscheiden zwei Typen: echtes Aluminiumstearat, das beim Umfällen gleiche Zusammensetzung behält, und Pseudo-Aluminium-stearate, die beim Umlösen und Umfällen neben löslichen Anteilen mit steigendem Aluminiumgehalt freie Säure und aluminiumreiche Gele bilden. Die Entstehung beider Typen hängt von den Reaktionsbedingungen ab und wird eingehend erörtert. Die unbeständigen Pseudo-Aluminiumstearate entstehen aus vorgebildetem Aluminiumhydroxyd und Stearinsäure. Die Untersuchungen des echten Aluminiumstearates führen zu völliger Übereinstimmung mit Ergebnissen G. Jander's über die Hydrolyseprodukte anorganischer Aluminiumsalze. Das Aluminiumstearat bildet hiernach ein basisches Salz, das der Formel (C18H35O2)2Al · O · [Al(C18H35O2) · O]6 · Al(C18H35O2)2 · aqua entspricht. Dagegen sind die Pseudo-Aluminiumstearate als mehr oder weniger unbeständige Anlagerungsprodukte von Stearinsäure an verschiedene Aluminiumoxydhydrate aufzufassen. Die Darstellung von zwei- und dreisäurigen Aluminiumsalzen gelang nicht. —Aluminiumstearat und Pseudo-Aluminiumstearate tauschen bei der Umsetzung mit Alizarin die Stearinsäure gegen Alizarin aus. Aus dem Aluminiumstearat bilden sich beständige, basische Aluminiumalizarate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 26 (1939), S. 273-276 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Pregls procedure for the micro-combustion of very volatile liquids cannot be employed for the determination of nitrogen in these byDumas' method. An arrangement is described in the paper which allows the combustion of easily volatile liquids to be carried out with certainty. The liquid is contained in a small capillary tube, which is itself inserted into a specially-shaped projecting part of the combustion tube, capable of being easily cooled; the point of the capillary is blown out by heating it with an electrically-heated wire. The above arrangement is equally well adapted for the determination of carbon and hydrogen.
    Abstract: Résumé La méthode dePregl (le mode de fonctionnement) pour la microanalyse par combustion des liquides à haute tension n'est pas utilisable pour la microdétermination de l'azote aprèsDumas. On décrit un appareil à l'aide duquel le procédé de la combustion des liquides très volatiles peut être exécuté avec grande sûreté. Le tube à combustion contient un tube capillaire, rempli du liquide, dans un dépôt formé en épine, qui peut être facilement réfrigeré; le bout pointu du tube capillaire est ouvert par un fil recuit, chauffé électriquement. La même disposition est apte à la détermination du carbone et de l'hydrogène.
    Notes: Zusammenfassung DiePreglsche Arbeitsweise zur mikroanalytischen Verbrennung von Flüssigkeiten mit hohem Dampfdruck ist für Mikro-Stickstoffbestimmungen nachDumas nicht anwendbar. Es wird eine Anordnung beschrieben, mit deren Hilfe der Verbrennungsvorgang leicht flüchtiger Flüssigkeiten mit Sicherheit geleitet werden kann. Das Verbrennungsrohr beherbergt in einem leicht kühlbaren, dornförmigen Ansatz die mit der zu verbrennenden Flüssigkeit gefüllte kleine Kapillare, deren Spitze durch einen elektrisch geheizten Glühdraht aufgeblasen wird. Die Anordnung ist desgleichen für die Bestimmung des Kohlenstoffes und Wasserstoffes geeignet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 26 (1939), S. 264-272 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A micro buoyancy balance has been devised to meet the requirements of micro density determinations made in volatile liquids, or for those cases where a number of consecutive determinations in flowing liquids contained in closed apparatus is needed. The balance and float are combined in a single piece. The horizontal single-armed spring balance consists of a fine thread of glass, the hollow balance arm carrying inside it a tiny granule of iron which serves as a rider. By shifting the rider the balance is adjusted to the zero position in the liquid whose density is to be determined; density determinations are thus reduced to a linear measurement. Two methods are discussed for shifting the rider and measuring the amount of displacement: 1. Adjustment of the rider by means of an alternating current magnet, operated through a micrometer screw. 2. A visual method with direct measurement of the extent to which the rider has been shifted. Calibration is effected by using liquids of known density. The micro buoyancy balance is suitable for use with mobile liquids, and can also be employed for consecutive determinations of density in flowing liquids, e. g. in fractional vacuum distillation. Instructions are given for making the balance.
    Abstract: Résumé Pour les besoins d'une méthode de micro-détermination de la densité, on a construit une micro-balance à force ascensionnelle pouvant être utilisée aussi bien pour les liquides à haute tension de vapeur que pour des déterminations successives dans des liquides en mouvement et dans des appareils fermés. Balance et corps submersible sont réunis dans le liquide en un seul élément. La balance à fléau unique et horizontal se compose d'un fil de verre très mince; ce bras, creux, renferme un noyau de fer servant de poids mobile. On règle la balance au zéro dans le liquide à mesurer, si bien que la mesure de densité est réduite à une mesure de longueur. Il existe deux méthodes pour effectuer le déplacement et mesurer la longueur: 1. On amène le poids mobile dans sa bonne position au moyen d'un électroaimant dont le déplacement se fait par une vis micrométrique. 2. Méthode visuelle par mesure directe de la distance du poids mobile repoussé, soit mécaniquement, soit par aimant. L'étalonnage de la balance se fait avec des liquides dont les densités sont connues. La micro-balance à force ascensionnelle convient aux liquides facilement mobiles et peut être employée pour la mesure permanente de la densité dans les liquides qui s'écoulent, par exemple lods d'une distillation fractionnée dans le vide. Sont encore mentionnées les instructions pour la fabrication d'une telle micro-balance.
    Notes: Zusammenfassung Dem besonderen Bedürfnis nach einer Methode zur Mikro-Dichtebestimmung, sowohl für Flüssigkeiten mit hohem Dampfdruck als auch für fortlaufende Dichtemessungen in strömenden Flüssigkeiten und in geschlossenen Apparaten, wurde durch Entwicklung einer Mikroauftriebswaage entsprochen. Waage und Senkkörper befinden sich, zu einem Bestandteil vereinigt, in der Flüssigkeit. Die horizontale einarmige Federwaage besteht aus einem feinen Glasfaden, der daran befindliche hohle Waagenarm trägt innen einen Eisenkern als Laufgewicht. In der zu messenden Flüssigkeit wird durch Verschiebung des Laufgewichtes die Waage auf eine Nullstellung gebracht. Die Dichtemessung wird somit auf eine Längenmessung reduziert. Es werden zwei Methoden der Verschiebung und Längenmessung besprochen: 1. Einstellung des Laufgewichtes mittels eines Wechselstrommagneten, dessen Verschiebung durch ein Schraubenmikrometer erfolgt. 2. Visiermethode unter direkter Messung des Abstandes des mechanisch oder magnetisch verschobenen Laufgewichtes. Die Eichung erfolgt durch Messung an Flüssigkeiten bekannter Dichte. Die Mikroauftriebswaage eignet sich für leichtbewegliche Flüssigkeiten und kann zur fortlaufenden Dichtemessung in strömenden Flüssigkeiten, z. B. bei der fraktionierten Vakuumdestillation, verwendet werden. Anschließend werden Anleitungen zur Herstellung der Mikroauftriebswaage gegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 77 (1944), S. 331-334 
    ISSN: 0365-9631
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...