ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 36 (1998), S. 265-280 
    ISSN: 0887-6266
    Schlagwort(e): entangled polymer solution ; double-step strain rate ; flow birefringence ; tube model ; segmental stretch ; Physics ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: Experiments measuring the orientation angle and birefringence in startup and double-step strain rate flows were conducted on a 3.0 wt % 8.42 × 106 molecular weight polystyrene solution in a Couette flow cell. A phase-modulated flow birefringence apparatus was used to noninvasively probe the sample. Upon startup from rest, the orientation angle undershoots its final steady-state value, as seen by earlier investigators. When the shear rate undergoes a step increase from one nonzero value to another, the amplitude of this undershoot is decreased. However, a more significant effect is a shorter time scale overshoot in the orientation angle that is highly counterintuitive in the sense that an increase of shear rate initially produces a rotation of chain segments away from the flow direction. Similarly, a step decrease in shear rate yields an initial transient rotation toward the flow direction. In both cases, the height of the peaks depends upon the magnitude of the shear rate jump, and the width of the peaks is a function of the final shear rate. The longer time transients in the startup and step increase experiments reflect an apparent change in the relaxation time for segment orientation, which we tentatively attribute to a combination of tube dilation and convective constraint release. The shorter time scale over- and undershoots in the orientation angle appear to be qualitatively explained by considering the differences in extension or contraction of segments along the polymer chain. © 1998 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 36: 265-280, 1998
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...