Summary A reversed-phase high performance liquid chromatographic method on C-18 bonded silica is described for the separation of trisubstituted iodo/bromothyronines, which exert thyroid hormone activity. The composition of the mobile phase has been systematically optimized resulting in a ternary mixture of methanol/acetonitrile/water acidified with trifluoroacetic acid. The applicability of ultraviolet absorption detection, amperometric detection and off-line radioimmunoassay was investigated. The latter method allows detection of the different iodo/bromothyronines down to 40–120 ng/l mobile phase; this sensitivity is high enough for application to thyroid hydrolysates in order to clarify the question as to whether bromine can substitute iodine in the biosynthesis of thyroid hormones.