ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 9 (1975), S. 47-61 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of squirrel monkeys received segmental femoral replacements in a study of the strength of the interface developed between the implant and bone. Implants were either made completely of bioglass-ceramic, or 316L stainless steel with a flame-prayed coating of bioglass. Fracture torque, energy at fracture, and shear stress at failure were compared to values obtained from a control group of pairs of tibias. Femurs containing bulk bioglassceramic implants showed about a 25% difference in strength compared to the opposite bone, while femurs containing flame-sprayed implants exhibited extremely low structural strength. While the strength of the metal-glass bond was very low (〈500 kgf/cm2), the bonebioglass bond was found to be at least as strong as the bioglass-ceramic, and at least 3/4 as strong as the host bone.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗