ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (3,042,650)
  • Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics  (1,588,272)
  • Mathematics  (901,864)
  • Electrical Engineering, Measurement and Control Technology  (574,657)
Collection
Years
Topic
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2856-2860 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We demonstrate a linear radio-frequency trap for confining strontium ions that is simply constructed nearly entirely with commercial off-the-shelf components. The electrodes of this trap are spaced to allow tight radial confinement, and segmented to give tight axial confinement with minimal distortion of the radio-frequency field. The resulting secular frequencies of the trap are 1 MHz in the radial direction and 100 kHz in the axial direction, the ions can be imaged with 2–3 μm resolution, and we detect over 20 000 photons per second per ion. This article describes the construction of the vital parts of the trap system, the laser system and optics used to Doppler cool the ions and to observe quantum jumps, and the operation and behavior of the complete system. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2849-2851 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The design and operation of an ultrahigh vacuum (UHV) compatible ionization chamber for fluorescent x-ray detection in the hard-x-ray regime is described. The detector is comprised of two main components: an UHV compatible, bakeable housing and multiple, 90% transparent, nickel wire-mesh internal collectors. The detector has been used successfully to study molecular beam epitaxy prepared metal thin films in situ. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2882-2885 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: High-frequency oscillations (1–100 MHz) in Hall thrusters have not received sufficient experimental scrutiny. A diagnostic setup, consisting of a single Langmuir probe, a special shielded probe connector-positioner, and an electronic impedance-matching circuit, was successfully built and calibrated. Through simultaneous high-frequency probing of the Hall-thruster plasma at multiple locations, high-frequency plasma waves have been successfully identified and characterized (Ref. 1). © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2890-2899 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Aperture, pin-hole and collimator detection systems are often used in plasma diagnostics, for example, in soft x-ray detection and bolometer systems. In this article the simultaneous optimization of viewing-beam overlap and light yield is considered in multi-channel aperture and collimator systems for two-dimensional (2D) tomography. This article briefly highlights the relation between beamwidth overlap and spatial aliasing in tomography, and how aliasing can be avoided in theory and in practice. Three-dimensional (3D) single-channel aperture and collimator systems can be approximated by a combination of two planar systems if the aperture is rectangular. Three ways to optimize beamwidth overlap and light yield for planar aperture and collimator systems are considered in detail: overlap of the angular étendue at the full width at half maximum (FWHM), overlap of the geometric function at the FWHM a certain distance from the aperture, and arbitrary overlap for a given maximum beamwidth. The combination of 2D effects from all three optimization methods were used in the design of 3D apertures for a new multi-channel bolometer camera on the Joint European Torus tokamak. The resulting apertures are complex, but the new camera has several advantages over previous cameras. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2963-2970 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Two problems of technological importance for microelectromechanical systems (MEMS) and microelectronics industry are addressed: fatigue of thin films and nanoscale film cracking. A device is described that can (1) conduct biaxial fatigue tests on thin films and (2) be utilized to study fracture patterns in nanoscale coatings under biaxial stress state. Thin-film specimens, in the form of circular membranes, are exposed to cyclic pressures between two fixed pressure limits. Corresponding pressure and specimen deflection are measured. Experimental results, including hysteresis loops spanning deflections of 15–50 μm are presented for 4.6-μm-thick polyimide films. Furthermore, the evolution of crack patterns in a 150-nm-thick Al film deposited on a polyimide substrate is studied. Critical mode I stress intensity factor for Al is extracted from experimental results. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2974-2980 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The characterization of a direct current, low-pressure, and high-density reflex discharge plasma source operating in argon and in nitrogen, over a range of pressures 1.0–10−2 mbar, discharge currents 20–200 mA, and magnetic fields 0–120 G, and its parametric characterization is presented. Both external parameters, such as the breakdown potential and the discharge voltage–current characteristic, and internal parameters, like the charge carrier's temperature and density, plasma potential, floating potential, and electron energy distribution function, were measured. The electron energy distribution functions are bi-Maxwellian, but some structure is observed in these functions in nitrogen plasmas. There is experimental evidence for the existence of three groups of electrons within this reflex discharge plasma. Due to the enhanced hollow cathode effect by the magnetic trapping of electrons, the density of the cold group of electrons is as high as 1018 m−3, and the temperature is as low as a few tenths of an electron volt. The bulk plasma density scales with the dissipated power. Another important feature of this reflex plasma source is its high degree of uniformity, while the discharge bulk region is free of electric field. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2988-2993 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We present a new three-step auto-alignment algorithm for the specimen stage of an ellipsometer with adjustable angle of incidence. Correction of errors in tilt angle and position of the specimen stage can be performed by locating the reflected light spot at the center of the detector at two different angles of incidence. The current method does not need auxiliary focusing equipment. The alignment algorithm works to high precision in both model simulation and practical experiments with a rotating analyzer ellipsometer. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 2994-2998 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A measuring system that integrates a low-temperature optical cell UV-visible (UV-Vis) for air exclusion experiments with a liquid x-ray absorption spectroscopy (XAS) cell (x-ray absorption near-edge spectroscopy and extended x-ray absorption fine structure) is reported here together with its application in studies of organometallic complexes. UV-Vis measurements are performed in a three-compartment glass vessel, fitted with an external fiber optics probe. This UV-Vis cell is suitable for the measurement of oxygen- and air-sensitive compounds at variable temperatures (RT to −78 °C). The liquid XAS cell is filled with the UV-Vis solution at low temperature and can be used in both fluorescence- or transmission-mode measurements with (frozen) solutions. The complete measuring system is reusable and easy to clean and handle. To test the performance of these cells the oxygenation behavior of a dinuclear organometallic copper(I) complex was studied in acetone by UV-Vis and XAS. It is shown that direct correlation of low-temperature UV-Vis and XAS data is possible in organic solvents. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 1985-1993 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We have conducted measurements at five different thermal neutron wavelengths to determine the transmission characteristics of a tapered monolithic focusing lens with a focal length of 100 mm, suitable for time-of-flight diffraction. Both the width of the focused beam and the intensity gain of the optic increase as a function of wavelength. We have performed similar measurements on a polychromatic beam on a pulsed neutron source, where the results are subject to background from short wavelength neutrons. The use of a beryllium filter shows the increased effective gain for the longer wavelengths at the expense of an increased focused beam width by a factor of 2. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 3133-3133 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...