ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 42.60  (90)
  • Springer  (90)
  • American Chemical Society (ACS)
  • 1980-1984  (90)
Collection
Publisher
  • Springer  (90)
  • American Chemical Society (ACS)
Years
Year
  • 1
    ISSN: 1432-0649
    Keywords: 32.80 ; 42.60 ; 6.30
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The velocity distribution of evaporated Zr atoms has been measured by means of laser-induced fluorescence using a cw dye laser by scanning the laser line across the Doppler-broadened absorption line profile of the atoms. It is shown that the experimental data can be explained on the basis of an excitation theory for a three-level system developed from basic principles. It was calculated that the probability for an atom to be in the excited state mainly depends on the radiation-power density of the laser and on the residence time of the atom in the exciting laser light. It was found that the laser frequency must be well stabilized in order to meet the assumptions in the excitation calculation. Otherwise deviations to the theoretical predictions appear in the experimental results due to the jitter of the dye laser.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 35 (1984), S. 123-126 
    ISSN: 1432-0649
    Keywords: 42.50 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Spatial separation of wavelengths in a CO2-laser resonator helps to avoid competitions. We have achieved this by means of a nearly concentric resonator with a grating or prism in its center. Thus, we demonstrated independent multiline emission with a variety of output spectra. The temporal sequence of the lines was conveniently controlled by varying their losses.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0649
    Keywords: 42.60 ; 07.65
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 135-142 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60 ; 42.80
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract An analysis of cw synchronously pumped dye lasers is presented. Under the assumption that the cavity (tuning element) bandwidth is much wider than the bandwidth of the transform limited pulses generated, the pulse forming dynamics is rigorously treated. It is shown that for a finite mismatch between the lengths of the dye and the pump lasers, a steady-state pulse develops in the dye laser cavity with a conserved pulseshape. The characteristics (energy, shape, peak power, duration) of these pulses of ultimate width are quantitatively determined as a function of cavity mismatch. An analytical solution for the pulse envelope is determined, which yieldsI(t)∝Sech2(t/t p ) to a good approximation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 30 (1983), S. 161-176 
    ISSN: 1432-0649
    Keywords: 32 ; 42.50 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A new method for determining trace amounts of elements in a substance has been developed. It is based on thermal evaporation and atomization of a substance in vacuum and detection of the released trace atoms by the laser stepwise photoionization technique. A rather effective way of detecting atoms is their multistep excitation to Rydberg states by the radiation of tunable dye lasers with their subsequent ionization by electric field pulses. The analytical laser spectrometer consisting of several tunable, pulsed dye lasers, a vacuum chamber with an atomizer and a recording system is described. The microimpurities of elements have been detected in pure materials: the contents of Na impurities in CdS crystals (2×10−6%) and Al impurities in germanium (2×10−7%). The detection limit of about 10−9% was determined. A technique for direct determination of the content of elements in natural water and human blood is described. A high sensitivity, universality and other merits of the method enable it to be used in determining traces of many important elements at a level of 10−8 to 10−11% almost in any matrix.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-0649
    Keywords: 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have shown that distributed feedback dye lasers are capable of generating single transform-limited pulses of 1.6–3.5 ps duration when pumped by a mode-locked Nd: YAG laser. A short-pulse amplifier has been constructed in which the level of amplified spontaneous emission could be kept below 10−3 by properly taking into account the polarization anisotropy of the gain and by precise timing of the pump pulses. A sensitive autocorrelator is described which allows to measure pulse duration in a single shot.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-0649
    Keywords: 42.60 ; 42.65 ; 61.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Absorption recovery kinetics data on the picosecond time-scale of a high signalto-noise ratio can be obtained by using continuously operating synchronously modelocked dye lasers. We show that such data make it possible to determine multiple exponential decays with small differences in rate constants. We also show that an absolute prerequisite to accomplish this is that the measurements are performed at a number of different wavelengths, and that the decays are monitored in a time interval corresponding to several lifetimes. These considerations are demonstrated by measurements on two carbocyanine dyes, DQOCI and pinacyanol, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 32 (1983), S. 127-135 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A cw uv copper hollow cathode laser is described, which could be operated for a longer time duration with an output power of 7 mW in the 260 nm region. A double-cathode configuration with a protection for the mirrors from metal-vapour deposition is presented. Characteristics of the laser output power, the spontaneous emission, and the ion densities in the negative glow were measured as depending on the discharge current, the neon gas pressure, and the size of the cathode slit. The observed saturation of the laser output power at high discharge current (1 A/cm2) and the optimum slot size are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 23-27 
    ISSN: 1432-0649
    Keywords: 42.55 ; 42.60
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract For the first time stable cw output of a FIR-CO2 hybrid laser has been achieved at wavelengths shorter than 300 μm. Due to the saturable absorber characteristic of the FIR laser gas, cw or pulsed emission is observed on both, the CO2 and the FIR laser output, depending on the operating conditions. Results are reported on different resonant lines in CH3OH and the 67 μm Raman line in NH3. The good efficiency of this laser is also demonstrated by the excitation of two new emission lines in CH3OH, namely 49 and 56 μm, pumped by 9R(22) and 9R(24), respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Applied physics 33 (1984), S. 57-61 
    ISSN: 1432-0649
    Keywords: 33 ; 42.60 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A laser photodesorption microscope has been applied to obtain 4×103-fold images of rhodamine crystals on a tip with a diameter of 66μm. Peculiarities of the formation of these images have been studied with different values of electric field strength on the tip and laser pulse intensities.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...