ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (7,768)
  • 1985-1989  (5,640)
  • 1970-1974  (2,128)
Collection
Publisher
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 601-608 
    ISSN: 0886-9383
    Keywords: Gas phase flow injection analysis ; Membrane-differentiated analysis ; Multicomponent determinations ; Successive linear regression ; Successive regression in fiduciary region ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A membrane-discriminated gas phase analyzer is proposed for multicomponent determinations. Nitrogen gas flows countercurrent through outer and inner channels in a tube-in-tube arrangement. The only communication between the two channels occurs through a 500 μm aperture covered by a porous PTFE membrane. A mixture of organic compounds (up to four components) is injected into the inner channel by a heated backflushed injector and the sample components diffusing into the outer channel are monitored by a flame ionization detector (FID). A calibration set, consisting of pure components, binary, ternary and quaternary mixtures (a total of 64 samples), provides the known data base: temporal profiles of the FID output as a function of sample composition. Although the overall response behavior is not a linearly additive function of individual analyte concentrations, the use of successive inverse multiple linear regression (while continually altering the choice of the calibration samples considered for the forward regression, on the basis of the most recent values of the predicted unknown sample composition) is shown to yield analytical results for unknown samples that are in good agreement with their true values.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 609-609 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 39-42 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The application of gas chromatography/mass spectrometry to three thermally labile phenylurea pesticides is reported. Using alcohols as solvents the decomposition of the pesticides is followed by a reaction in which esters of N-(3,4-dichlorophenyl)carbamic acid are formed. As these reactions occur during the gas chromatographic analysis, it is the esters which are identified in the mass spectrometer. The methyl ester is itself a pesticide so an erroneous conclusion about the original pesticide could be reached when methanol is the solvent.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 43-45 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The ions produced by 252Cf plasma desorption are detected by Fourier transform ion cyclotron resonance techniques. Results for CsI and N,N,N-trimethyl-p-aminophenolate iodide show the feasibility of the technique with high resolution (up to 11 000 at m/z 23) and good signal-to-noise ratio (up to 726).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 47-48 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 49-50 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 51-51 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 53-61 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The fast atom bombardment positive ion mass spectra and the [M + H]+ collisional activation spectra of t-butyloxycarbonyl protected peptides and the unprotected analogues have been compared. It is concluded that sequence information, especially from the collisional activation spectra, can better be derived from the underivatized peptides than from the BOC-peptides.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 229-233 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The constant B2E linked scan is shown to be an excellent tool for the profiling of biogenic amines in wine samples. The fragment ion at m/z 169 of the dansylated amines is used for the precursor ion search in combination with direct sample evaporation. Besides the profile a semi-quantification may be achieved when using suitable amines as internal standards with standard deviations of 12-17%. More accurate results with standard deviations of 3-5% are obtained when using deuterated analogues as internal standards. Both methods are applied to the analysis of biogenic amines in synthetic mixtures and actual wine samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 241-246 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: 252-Californium plasma desorption mass spectrometry was applied to the study of five different classes of phospholipids namely phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine and phosphatidylinositol. Positive and negative ion spectra were compared to spectra obtained using other ionization techniques. Plasma desorption mass spectra provide useful information on the molecular weight of compounds from all classes, particularly in the case of phosphatidylserine - a class that has failed to show satisfactory quasimolecular ions with either Fast atom bombardment, FAB or Field desorption, FD. The observed fragmentation is also indicative of the structure of the studied compounds.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...