ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Analytical Chemistry and Spectroscopy
  • ASTROPHYSICS
  • 2000-2004  (101)
Sammlung
Verlag/Herausgeber
Erscheinungszeitraum
Jahr
  • 1
    ISSN: 0935-6304
    Schlagwort(e): 2H/1H ratio analysis ; HRGC-P-IRMS ; stable isotopes ; benzaldehyde ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---Isotope ratio monitoring gas chromatography-mass spectrometry of the 2H/1H ratio by pyrolysis isotope ratio mass spectrometry (P-IRMS) was used to analyze benzaldehyde originating from various sources. Based on the δ2HSMOW value of an authentic reference sample determined with an elemental analyzer (EA), the range of reproducibility and linearity was checked. Correct (EA related) and reproducible data were obtained for sample amounts 〉0.6 μg benzaldehyde (on column). In another series of experiments, the influence of sample preparation, i. e. simultaneous distillation-extraction (SDE) was found to be negligible. The following ranges of δ2HSMOW values were determined for benzaldehyde using five types of samples, i. e. (i) synthetic (δ2HSMOW -78 to -85‰, ex benzal chloride; +420 to +668‰, ex toluene) and ‘natural’ (including ‘ex-cassia’) references (δ2HSMOW -83 to -144‰); (ii) bitter almond oils (δ2HSMOW -113 to -148‰); (iii) fruits (δ2HSMOW -111 to -146‰); (iv) kernels (δ2HSMOW -115 to -188‰); and (v) leaves (δ2HSMOW -165 to -189‰).
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 497-501 
    ISSN: 0935-6304
    Schlagwort(e): Historical remarks ; modern separation methods ; gas chromatography ; selective sorbents ; selectors ; discovery process ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The research conducted and the discoveries during the development of chromatography are briefly surveyed, with emphasis being placed on gas chromatography. Some actors are presented who played major roles en route from Tswett's original discovery to modern separation methods. The article is based mainly on personal memories and encounters. A few examples of the participation of our country in the development of chromatography are mentioned as well as international contacts. Some remarks are made on the use of selective sorbents or selectors in modern analytical separations. The paper closes with a few comments on the “philosophy” of the discovery process.
    Zusätzliches Material: 1 Tab.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 93-99 
    ISSN: 0935-6304
    Schlagwort(e): HPLC ; monolithic column ; silica rod column ; fast separations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---The application of a new silica-based, monolithic-type HPLC-column for fast separations is presented. The column is prepared according to a new sol-gel process, which is based on the hydrolysis and polycondensation of alkoxysilanes in the presence of water soluble polymers. The method leads to “rods” made of a single piece of porous silica with a defined pore structure, i. e. macro- and mesopores. The main feature of silica rod columns is a higher total porosity, about 15% higher than of conventional particulate HPLC columns. The resulting column pressure drop is therefore much lower, allowing operation at higher flow rates including flow gradients. Consequently, HPLC analysis can be performed much faster, as it is demonstrated by various applications.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 677-680 
    ISSN: 0935-6304
    Schlagwort(e): Capillary ; fast separations ; mass spectrometry ; vacuum ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---There is a constant drive to speed up GC separations. Shorter analysis times provide more analyses per day, which reduces cost. One approach is to reduce column length and column diameter and columns of 0.15 mm i.d. have indeed grown in popularity. However, the majority of applications are still done with 0.25 mm and 0.32 mm columns.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 489-496 
    ISSN: 0935-6304
    Schlagwort(e): Flavor ; odorant ; headspace ; GC ; interaction ; electronic nose ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---In order to understand the flavor of foods a multitude of scientific investigations have been carried out and a number of analytical tools for flavor research developed in the last few decades. Initially, scientific investigations focused mainly on the identification of all compounds that could contribute to the flavor. Olfactory GC techniques permitted the division of identified volatiles into odor-active and non-odor-active. Many techniques were developed to enhance the quality and the information content of the flavor results. Since the early 1990s, analytical investigations have dealt with interactions between food matrices and flavor compounds and the human influence on the retardation of odorants. New analytical methods concentrate on the headspace of the sample by using static or dynamic headspace analysis, or deal with measurements of volatile release in the mouth by a novel nose sampler and oral vapor GC. These useful tools clarify the effects of breathing, chewing, and saliva flow on flavor release. Though the human nose performs well at low concentrations of odorants, it is a medium-term aim to replace the use of the human nose by analytical techniques. Future investigations will probably deal with the interactions of odorants and the human receptors and it is mainly these receptors that will play a key role in aroma research. By analysis of the effects of odorants on the receptors the mechanisms of odor perception will be elucidated. This will enable the development of supporting analytical tools like electronic noses that really do function as noses, or “neural networks”.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    ISSN: 0935-6304
    Schlagwort(e): Monolith ; factor VIII ; affinity chromatography ; combinatorial peptide library ; peptide synthesis ; recombinant proteins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: FVIII is a very complex molecule of great therapeutic significance. It is purified by a sequence of chromatographic steps including immunoaffinity chromatography. A peptide affinity chromatography method has been developed using peptides derived from a combinatorial library. Spot technology using cellulose sheets has been applied for this purpose. The dual positional scanning strategy was used for identification of the amino acids in random positions. Approximately 5000 possible candidates found in the first screening round were reduced to a panel of 36. Six candidates have been selected empirically. Five peptides seem to be directed against the light chain of FVIII, one peptide seems to be directed against the heavy chain. The peptides have been immobilized on conventional beaded material and CIM polymethacrylate monoliths. Much better performance with respect to capacity and selectivity has been observed with the monolithic material. Exposure of the ligand and its ensuing accessibility are responsible for these properties.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 27-38 
    ISSN: 0935-6304
    Schlagwort(e): Monolith ; continuous bed column ; convective interaction media ; membrane chromatography ; membrane adsorber ; HPMDC ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Monolithic stationary phases have revolutionized protein chromatography because they combine speed, capacity, and resolution in a unique manner. Since such stationary phases contain no particles but only flow-through pores, the usual mass transfer restrictions to the chromatography of large molecules are not observed and extremely fast separations become possible. Recently the area of application of monolith chromatography has been extended to the separation and analysis of small molecules and plasmid DNA. This review summarizes the state of art in high performance monolith and especially high performance monolithic disk chromatography (HPMDC). The current understanding of the theory of protein HPMDC is summarized, while an introduction to the evolving field of small molecule HPMDC is attempted. The basic differences between the monolithic disks and columns packed with conventional stationary phases (including perfusion and micropellicular particles) but also monolithic columns (porous rods) are outlined. Finally, the potential of HPMDC to analytical and preparative biochromatography is demonstrated by a discussion of recent applications of chromatographic disks for protein isolation and bioprocess analysis.
    Zusätzliches Material: 14 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 338-342 
    ISSN: 0935-6304
    Schlagwort(e): Polyunsaturated fatty acids (PUFA) ; high performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-MS with APCI) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Analysis of polyunsaturated fatty acids using high performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry is described. The standard fatty acid methyl esters from 16 to 22 carbons were analyzed by LC-MS with APCI. The effect of orifice voltage and total carbon atoms versus number of double bonds in each homologue on the mass spectra is discussed. The correction coefficients for homologues from saturated fatty acids to hexaenoic acid are also mentioned.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 208-214 
    ISSN: 0935-6304
    Schlagwort(e): Spearmint ; peppermint ; GC×GC ; essential oils ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: ---This paper investigates the separation of moderately complex samples by comprehensive two-dimensional gas chromatography (GC×GC). The analysis of peppermint (Mentha piperita) and spearmint (Mentha spicata) essential oil components, including acetates, alcohols, furans, ketones, sesquiterpenes, and terpenes, was achieved by one-dimensional gas chromatography with quadrupole mass spectrometry detection (GC/MSD) and GC×GC with flame ionization detection. Peppermint essential oil was found to contain 89 identifiable peaks by GC×GC compared to 30 peaks in the GC/MSD chromatogram. Likewise, 68 peaks were found in the GC×GC chromatogram of spearmint (compared to 28 in GC/MSD). Plots of the first dimension versus second dimension retention times provided a fingerprint of the two essential oils, which revealed 52 similar compounds between the two essential oils as opposed to 18 matches by 1D GC.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 393-396 
    ISSN: 0935-6304
    Schlagwort(e): Supercritical fluid chromatography (SFC) ; micropacked capillary columns ; waxes ; restoring ; objects of art ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: No abstract
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...