ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

You have 0 saved results.
Mark results and click the "Add To Watchlist" link in order to add them to this list.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (5,640)
  • Humans  (1,943)
  • ddc:330
  • 1985-1989  (7,583)
Collection
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular evolution 27 (1988), S. 311-320 
    ISSN: 1432-1432
    Keywords: Genome composition ; Coding sequences ; Isochores ; Humans ; Murids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The compositional distributions of coding sequences and DNA molecules (in the 50-100-kb range) are remarkably narrower in murids (rat and mouse) compared to humans (as well as to all other mammals explored so far). In murids, both distributions begin at higher and end at lower GC values. A comparison of homologous coding sequences from murids and humans revealed that their different compositional distributions are due to differences in GC levels in all three codon positions, particularly of genes located at both ends of the distribution. In turn, these differences are responsible for differences in both codon usage and amino acids. When GC levels at first+second codon positions and third codon positions, respectively, of murid genes are plotted against corresponding GC levels of homologous human genes, linear relationships (with very high correlation coefficients and slopes of about 0.78 and 0.60, respectively) are found. This indicates a conservation of the order of GC levels in homologous genes from humans and murids. (The same comparison for mouse and rat genes indicates a conservation of GC levels of homologous genes.) A similar linear relationship was observed when plotting GC levels of corresponding DNA fractions (as obtained by density gradient centrifugation in the presence of a sequence-specific ligand) from mouse and human. These findings indicate that orderly compositional changes affecting not only coding sequences but also noncoding sequences took place since the divergence of murids. Such directional fixations of mutations point to the existence of selective pressures affecting the genome as a whole.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0878
    Keywords: Skeletal muscles ; Ultrastructure ; Exercise ; Glycogen ; Humans
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Distribution of glycogen particles in semithin and ultrathin sections of biopsy samples from human muscles subjected to either short- or long-term running were investigated using PAS and Periodic Acid-ThioSemiCarbazide-Silver Proteinate (PA-TSC-SP) staining methods. Glycogen particles were predominantly found immediately under the sarcolemma or aligned along the myofibrillar Iband. After long-term exhaustive exercise type-1 fibers with a few or no glycogen particles in the core of the fibers were frequently observed. The subsarcolemmal glycogen stores of these “depleted” type-1 fibers were about three times as large as after exhaustive short-time exercise. Another indication of utilization of subsarcolemmal glycogen stores during anaerobic exercise was that many particles displayed a pale, rudimentary shape. This observation suggests fragmental metabolization of glycogen. Thus, depending on type of exercise and type of fiber differential and sequential glycogen utilization patterns can be observed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 601-608 
    ISSN: 0886-9383
    Keywords: Gas phase flow injection analysis ; Membrane-differentiated analysis ; Multicomponent determinations ; Successive linear regression ; Successive regression in fiduciary region ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A membrane-discriminated gas phase analyzer is proposed for multicomponent determinations. Nitrogen gas flows countercurrent through outer and inner channels in a tube-in-tube arrangement. The only communication between the two channels occurs through a 500 μm aperture covered by a porous PTFE membrane. A mixture of organic compounds (up to four components) is injected into the inner channel by a heated backflushed injector and the sample components diffusing into the outer channel are monitored by a flame ionization detector (FID). A calibration set, consisting of pure components, binary, ternary and quaternary mixtures (a total of 64 samples), provides the known data base: temporal profiles of the FID output as a function of sample composition. Although the overall response behavior is not a linearly additive function of individual analyte concentrations, the use of successive inverse multiple linear regression (while continually altering the choice of the calibration samples considered for the forward regression, on the basis of the most recent values of the predicted unknown sample composition) is shown to yield analytical results for unknown samples that are in good agreement with their true values.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 3 (1989), S. 609-609 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 39-42 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The application of gas chromatography/mass spectrometry to three thermally labile phenylurea pesticides is reported. Using alcohols as solvents the decomposition of the pesticides is followed by a reaction in which esters of N-(3,4-dichlorophenyl)carbamic acid are formed. As these reactions occur during the gas chromatographic analysis, it is the esters which are identified in the mass spectrometer. The methyl ester is itself a pesticide so an erroneous conclusion about the original pesticide could be reached when methanol is the solvent.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 43-45 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The ions produced by 252Cf plasma desorption are detected by Fourier transform ion cyclotron resonance techniques. Results for CsI and N,N,N-trimethyl-p-aminophenolate iodide show the feasibility of the technique with high resolution (up to 11 000 at m/z 23) and good signal-to-noise ratio (up to 726).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 47-48 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 49-50 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 51-51 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 14 (1987), S. 53-61 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The fast atom bombardment positive ion mass spectra and the [M + H]+ collisional activation spectra of t-butyloxycarbonyl protected peptides and the unprotected analogues have been compared. It is concluded that sequence information, especially from the collisional activation spectra, can better be derived from the underivatized peptides than from the BOC-peptides.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...