ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (344)
  • Springer  (344)
  • American Chemical Society
  • Public Library of Science
  • 1995-1999  (344)
Collection
Keywords
Publisher
  • Springer  (344)
  • American Chemical Society
  • Public Library of Science
  • Wiley-Blackwell  (1)
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 99-101 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; High temperature open-tubular columns ; Solvent make-up ; Acetophenone oxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Acetophnone, a substance stable at room temperature, is readily oxidizes in a high temperature open tubular liquid chromatographic system by the residual oxygen in the mobile phase. The oxidation product is less UV absorptive and detection sensitivity decreases greatly. To prevent the oxidation, through degassing of the mobile phase is necessary.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Endotoxins ; Lipopolysaccharide ; Aminated poly(γ-methyl L-glutamate) ; Bovine serum albumin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method is described for the selective removal of endotoxins from various protein solutions using columns packed with aminated poly (γ-methyl L-glutamate) (PMLG-NH2) spheres. The PMLG-NH2 adsorbents showed a high adsorbing activity for endotoxins which had an ionic strength of μ=0.05–1.0 and pH 5.0–9.0. The endotoxin-adsorbing capacity per millitre of the wet adsorbent increased from 0.40 to 1.35 mg (E. coli O111: B4 LPS) at μ=0.2 and pH 7.0 while the aminogroup content of the adsorbent increased from 0.8 to 3.5 meq g−1. The PMLG-NH2-3.5 has an amino-group content of 3.5 meq g−1. This column packing selectively adsorbed endotoxins, without loss of the protein, from a γ-globulin or cytochromec solution which contained endotoxins at μ=0.05 and pH 7.0. On the other hand, when bovine serum albumin (BSA) was present in solution with endotoxins, both the endotoxins and the BSA were adsorbed by the column. The BSA-adsorbing activity increased with increasing amino-group content of the adsorbent. However, this undesirable adsorption was suppressed with increasing ionic strength of the buffer. As a result, when the packing which had an amino-group content of 1.5 meg g−1 was used in conditions of μ=0.2 and pH 7.0, the endotoxins were removed from a BSA-containing solution without affecting the recovery of the BSA.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 51-57 
    ISSN: 1612-1112
    Keywords: Column electrophoresis ; Column liquid chromatography ; Phenolic lignin degradation compounds ; Sugar degradation products ; Quantitative analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method for the quantitative analysis of phenolic lignin degradation products by capillary electrophoresis (CE) with on-column UV detection has been developed. The liquid biomass solutions contain low molecular hemicellulosic sugars and phenolic lignin degradation products with various degrees of polymerization. Special attention has been paid to the monomeric phenolic components of lignin degradation fragments, e.g. derivatives of phenolic acids, aldehydes, and alcohols. Uncoated fused silica capillaries and borate-phosphate buffer systems at moderate pH conditions were used in order to separate the compounds of interest. To provide validation of the method, the same samples were analyzed independently by HPLC using gradient elution on a RP-C18 column. As sugar degradation fragment, furan-2-carboxylic acid was detected.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 85-90 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Phenolic compounds ; Ion-pair solid phase extraction ; On-line trace enrichment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two packing materials, C18 and PLRP-S, are studied for on-line trace enrichment of phenolic compounds in water. Various precolumns of different internal diameter are also tested and the addition of an ion-pair reagent to increase retention and thus, breakthrough volumes of phenolic compounds, is studied. Best results are obtained when a PLRP-S precolumn is coupled on-line with a C18 analytical column and DAD detector. Addition of TBA considerably increases breakthrough volumes. In contrast, when a C18 precolumn is used, breakthrough volumes are lower and it is impossible to determine TCP and PCP, under the experimental conditions used, because of interference of other nonpolar compounds in the samples. The performance of the system is evaluated with river and tap water and the preconcentration of 10 ml of sample in a PLRP-S precolumn involves a linear range between 1 μg 1−1 and 20 μl−1 and limits of determination between 0.5 μg l−1 and 1 μg l−1 are obtained.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 631-637 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Trace analysis ; Pesticides in tap water ; Aromatic sulphonates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Methodology and instrumentation are described which allow chromatographic screening of water samples under substantially simplified conditions and at reduced cost. A single column is used to accomplish sample extraction, trace enrichment, and separation. The performance of such a system is demonstrated, and the results compared with conventionally used concepts.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Transchelation ; Zinc pyrithione and related compounds ; Antidandruff formulations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An analytical procedure has been developed for the determination of zinc pyrithione in antidandruff formulations. Zinc pyrithione was converted into a stable copper complex and then analysed by reversed-phase HPLC. The proposed method allows the separation of the analyte from related pyrithiones and therefore is able to verify the compliance of cosmetic preparations with current legislation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Benzodiazepines ; Solvent effects ; ACN clusters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Two different methods were used to determine the separation factor α at different temperatures and the Gibbs-Helmholtz parameters (Δ(ΔH), Δ(ΔS)) of two adjacent benzodiazepines on a chromatogram were obtained from plots of lnα versus 1/T. We first studied each factor (fraction of water ϕ in the ACN/water mixture and column temperatureT), which controls the retention mechanism, and then we examined the simultaneous variation of all these factors. The changes in Δ(ΔH) and Δ(ΔS) in relation to a volume fraction of water ϕ in an ACN/water mixture were examined. In the ACN/water system, Δ(ΔH) was fairly constant in the acetonitrile region of ϕ≤0.52 and appears to be a roughly linear function of ϕ for ϕ≥0.52. In this system Δ(ΔS) is approximately a parabolic function of ϕ with an optimum at ϕ≅0.52. The retention mechanism of ten benzodiazepines was found to be significantly different in the methanol/water and ACN/water mixtures. The separation optimization of these ten benzodiazepines was then considered. A fraction of water of 0.43 in the ACN/water mixture and a column temperature of 44°C gave the most efficient separation conditions in the ACN/water mixture.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyurethane degradation products ; 2,4- and 2,6-toluendiamine ; Urine analysis ; Breast implants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A reversed-phase HPLC method has been developed for the urinary determination of mutagenic 2,4- and 2,6-toluendiamines. These amines are degradation products of polyurethane, a material used to cover textured silicone breast implants. FMOC-Cl was used as fluorescent derivatising agent in order to obtain a limit of detection of 15 ng/ml in urine. Pre-treatment of urine samples was by liquid/liquid extraction and urine specimens of patients after surgury were analysed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 41 (1995), S. 657-660 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Polyphenols ; Flavonoids ; Phenolic acids and aldehydes ; Eucalyptus spp.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Standards of the polyphenols occurring in wood, bark and leaf extracts ofEucalyptus spp. (i.e. flavonoids and phenolic acids and aldehydes) have been analyzed by HPLC using reversed phase columns, gradient elution and diode-array detection. The conditions used are reported.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 40 (1995), S. 657-661 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed phases ; Polyencapsulated silica ; Polyacrylates
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary By copolymerization of silica modified with vinyl groups and acrylic acid esters in suspension highly efficient, polymeric-encapsulated stationary-phases can be prepared. The suspending liquid has to be selected such that the monomers are at least partially adsorbed on the surface and the polymer formed does not precipitate. Under these conditions stationary phases capable of speedy mass transfer can be prepared, where the reduced plate heights are between 2 and 3. The silica surface shielding is optimized so that basic and acidic solutes elute with symmetrical peak.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...