ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (70)
  • Wiley-Blackwell  (70)
  • Blackwell Publishing Ltd
  • 2015-2019
  • 1975-1979  (70)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 288-292 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phases, polar, gum type ; For temperatures up to 300°C ; For most of the common classes of organic compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Most of the common classes of organic compounds chromatograph normally on Superoxes. There is no tailing or adverse effect from excessively different activity different activity coefficients. Superoxes are therefore universal phases for gas chromatography. This is also expressed by a wide useful temperature range from ∼50° to ∼300°. High MW Superox-4 has a MAOT about 20° higher than the lower MW Superox-0.1. Several applications illustrating the versatility of Superox phases in (GC)2 are presented.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 429-435 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening by diatomaceous support (5 micron particles deposition) ; Organic glue (polar polymethacrylate acetate) used as intermediate material ; Reproducibility and durability of capillaries discussed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A technique for adhesion of fine particles (ca. 5 μ) of the 405 white diatomaceous support on the inner wall of glass tube with organic glue [poly (diethylaminoethyl methacrylate) acetate] is described. The coated tube was drawn to capillary column by using a machine designed according to Desty's. The capillary column was then coated with stationary phase (such as squaiane, QF-1, Dexsil 300, PEG 20 M, OV-1, SE 30 and etc.) by the conventional dynamic or static method. This preparation method has proved easy to duplicate and is simple. The coating efficiency (UTE %) is within 60-90. The theoretical plate number per meter of an SE 30 column is about 4000, and per meter of a PEG 20 M column is about 2500. The columns thus prepared have been successfully used to analyze petroleum hydrocarbons, essential oils, petrochemicals, pheromone, steroid metabolites and others.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 635-636 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cyclandelate quantitation ; In plasma. No sylilation needed ; Analysis within 16 min, range 5-50 ng/mikroliter ; Correlation coeff. 0.996 (N=6) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 177-183 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary ; Injection by tailored capsule-insertion technique ; Critical comparison with split-injection technique ; Competitive with best-known systems ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capsule-insertion system tailored to the needs of capillary gas chromatography is described. It provides the basis for a truly quantitative and improved qualitative approach to open tubular capillary GLC. The advantages of the system lie in its simplicity of handling and in the possibility of using relatively low injection temperatures, thus reducing the risks to thermally unstable samples.The observed high efficiencies characterizing this capillary GLC capsule technique allow full advantage to be taken of the operating capacity of the superior capillary columns to give a performance competitive with the best known split-injection systems.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 200-201 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Control of relative retention in series-coupled columns by temperature variation ; Effect of temperature variation on OV 101/Silar 5 column pair ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 254-254 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Hydrodesulphurization products elution ; Room temperature two-column operation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 283-287 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling technique ; Semi-automation of head space sampling ; Application to water pollution, coffee aroma, light hydrocarbons in crude oil ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Head space GC using a special electropneumatic sampling system works well in combination with glass capillaries. Because a homogenous gas mixture is already present most problems inherent with inlet splitters are thus avoided. In cases where the high vapor pressure of the sample can cause problems with the pressure controlled sampling system, the use of narrow bore glass capillaries provides the necessary inlet pressure. The use of this powerful and convenient analytical tool for water pollution analysis, flavour analysis and the analysis of volatiles in crude oil samples is shown by examples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 319-323 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Mobile phase flow programming ; Comparison with temperature programming ; Short capillaries offer considerable shorter analysis time when flow programmed ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The technique of programming the carrier gas flow rate in gas chromatography, especially in connection with the use of capillary columns shorter than 10 m can significantly accelerate GC analyses. Equations for calculation of the parameters of the exponential flow function and retention data are described. The effects of flow programming in a short capillary column are shown in a few chromatograms. Different programming rates are tested and compared with temperature programming.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 297-302 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface roughening ; Amorphous silica ; Deactivation ; Column performance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new method for the preparation of wall-coated glass capillary columns after surface roughening by means of amorphous silica is described. After the glass capillary has been leached, a small quantity of amorphous silica is deposited evenly on the inner surface. This is done by passing a plug of dilute water glass through the capillary, followed by a flow of gaseous hydrochloric acid. The roughened surface is stabilized, deactivated and finally coated.This paper furnishes details of the technique and information about the performance of a number of columns prepared by the method.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 324-328 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Theory in contrast to traditional approaches ; Very practical formulas for peak width, maximum load, concentration in mobile phase ; Optimizing procedure for trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In contrast to traditional theoretical approaches by calculation of (nonexistent) theoretical plates, a unified theory of gas chromatography as given by a definition of the resolution analogue to methods in signal processing or spectroscopy using the well-known Kovacz indices as fundamental scale. A derivation of the thusly defined resolution from basic physical principles yields very practical formulae for peak width, maximum load, substance flow in peak maximum, concentration of substance in the carrier gas and other interesting parameters in dependence of capillary diameter, capillary length, film thickness, carrier gas speed, viscosities etc. Diagrams show favourite conditions for detectors responding on absolute substance flow (e.g. FID) or on concentrations.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...