ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publication Date: 2021-09-29
    Description: The resolution function of a spectrometer based on a strongly bent single crystal (bending radius of 10 cm or less) is evaluated. It is shown that the resolution is controlled by two parameters: (i) the ratio of the lattice spacing of the chosen reflection to the crystal thickness and (ii) a single parameter comprising crystal thickness, its bending radius, distance to a detector, and anisotropic elastic constants of the chosen crystal. The results allow the optimization of the parameters of bent‐crystal spectrometers for the hard X‐ray free‐electron laser sources.
    Description: The resolution function of a bent‐crystal spectrometer for pulses of an X‐ray free‐electron laser is evaluated. Under appropriate conditions, the energy resolution reaches the ratio of the lattice spacing to the crystal thickness. image
    Keywords: 548 ; X‐ray free‐electron lasers ; X‐ray spectroscopy ; bent crystals ; diamond crystal optics ; femtosecond X‐ray diffraction
    Type: map
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-09-29
    Description: To study and control the incoherent inelastic background in small‐angle neutron scattering, which makes a significant contribution to the detected scattering from hydrocarbon systems, the KWS‐2 small‐angle neutron scattering diffractometer operated by the Jülich Centre for Neutron Science (JCNS) at Heinz‐Maier Leibnitz Zentrum (MLZ), Garching, Germany, was equipped with a secondary single‐disc chopper that is placed in front of the sample stage. This makes it possible to record in time‐of‐flight mode the scattered neutrons in the high‐Q regime of the instrument (i.e. short incoming wavelengths and detection distances) and to discard the inelastic component from the measured data. Examples of measurements on different materials routinely used as standard samples, sample containers and solvents in the experiments at KWS‐2 are presented. When only the elastic region of the spectrum is used in the data‐reduction procedure, a decrease of up to two times in the incoherent background of the experimentally measured scattering cross section may be obtained. The proof of principle is demonstrated on a solution of bovine serum albumin in D2O.
    Description: A new chopper has been installed at the sample position in front of the sample stage at the KWS‐2 small‐angle neutron‐scattering diffractometer of the Jülich Centre for Neutron Science. The pulsed beam and the time‐of‐flight data acquisition enable the separation of elastic and inelastic scattering from hydrogenous samples.
    Keywords: 548 ; TOF‐SANS ; incoherent neutron scattering ; inelastic neutron scattering ; hydrocarbon systems
    Type: map
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2021-09-29
    Description: Cubic rare‐earth sesquioxide crystals are strongly demanded host materials for high power lasers, but due to their high melting points investigations on their thermodynamics and the growth of large‐size crystals of high optical quality remain a challenge. Detailed thermal investigations of the ternary system Lu2O3–Sc2O3–Y2O3 revealing a large range of compositions with melting temperatures below 2200°C and a minimum of 2053°C for the composition (Sc0.45Y0.55)2O3 are presented. These reduced temperatures enable for the first time the growth of high optical quality mixed sesquioxide crystals with disordered structure by the conventional Czochralski method from iridium crucibles. An (Er0.07Sc0.50Y0.43)2O3 crystal is successfully grown and characterized with respect to its crystallographic properties as well as its composition, thermal conductivity and optical absorption in the 1 µm range.
    Description: The phase diagram of the ternary system Lu2O3–Sc2O3–Y2O3 is investigated and compositions with melting points below 2200°C are found. This allows for the first successful growth of the mixed cubic sesquioxide crystal (Er0.07Sc0.50Y0.43)2O3 by the Czochralski method from an iridium crucible. image
    Keywords: 548 ; crystal growth ; optical materials ; phase diagrams ; melting points ; rare earth sesquioxides
    Type: map
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2021-07-05
    Description: Mixed ionic electronic conducting ceramics Nd6−yWO12−δ (δ is the oxygen deficiency) provide excellent stability in harsh environments containing strongly reactive gases such as CO2, CO, H2, H2O or H2S. Due to this chemical stability, they are promising and cost‐efficient candidate materials for gas separation, catalytic membrane reactors and protonic ceramic fuel cell technologies. As in La6−yWO12−δ, the ionic/electronic transport mechanism in Nd6−yWO12−δ is expected to be largely controlled by the crystal structure, the conclusive determination of which is still lacking. This work presents a crystallographic study of Nd5.8WO12−δ and molybdenum‐substituted Nd5.7W0.75Mo0.25O12−δ prepared by the citrate complexation route. High‐resolution synchrotron and neutron powder diffraction data were used in combined Rietveld refinements to unravel the crystal structure of Nd5.8WO12−δ and Nd5.7W0.75Mo0.25O12−δ. Both investigated samples crystallize in a defect fluorite crystal structure with space group Fm3m and doubled unit‐cell parameter due to cation ordering. Mo replaces W at both Wyckoff sites 4a and 48h and is evenly distributed, in contrast with La6−yWO12−δ. X‐ray absorption spectroscopy as a function of partial pressure pO2 in the near‐edge regions excludes oxidation state changes of Nd (Nd3+) and W (W6+) in reducing conditions: the enhanced hydrogen permeation, i.e. ambipolar conduction, observed in Mo‐substituted Nd6−yWO12−δ is therefore explained by the higher Mo reducibility and the creation of additional – disordered – oxygen vacancies.
    Description: The crystal structures of non‐substituted and Mo‐substituted neodymium tungstates are described in detail through neutron diffraction and high‐resolution X‐ray diffraction. Combined X‐ray and neutron diffraction refinements and electron probe micro‐analysis were employed to locate Mo atoms in the crystal structure of Nd6−yW1−zMozO12−δ (z = 0, 0.25), while X‐ray absorption spectroscopy in the near‐edge regions confirmed no changes in the oxidation states of Nd and W.
    Keywords: 548 ; powder diffraction ; mixed conductors ; X‐ray absorption spectroscopy (XAS) ; Nd6−yWO12−δ
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2021-07-03
    Description: X‐ray reflectivity (XRR) is a powerful and popular scattering technique that can give valuable insight into the growth behavior of thin films. This study shows how a simple artificial neural network model can be used to determine the thickness, roughness and density of thin films of different organic semiconductors [diindenoperylene, copper(II) phthalocyanine and α‐sexithiophene] on silica from their XRR data with millisecond computation time and with minimal user input or a priori knowledge. For a large experimental data set of 372 XRR curves, it is shown that a simple fully connected model can provide good results with a mean absolute percentage error of 8–18% when compared with the results obtained by a genetic least mean squares fit using the classical Parratt formalism. Furthermore, current drawbacks and prospects for improvement are discussed.
    Description: Artificial neural networks trained with simulated data are shown to correctly and quickly determine film parameters from experimental X‐ray reflectivity curves.
    Keywords: 548 ; X‐ray reflectivity ; machine learning ; organic semi‐conductors ; neural networks
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2021-07-02
    Description: A new concept for temporal gating of synchrotron X‐ray pulses based on laser‐induced thermal transient gratings is presented. First experimental tests of the concept yield a diffraction efficiency of 0.18%; however, the calculations indicate a theoretical efficiency and contrast of 〉30% and 10−5, respectively. The full efficiency of the pulse picker has not been reached yet due to a long‐range thermal deformation of the sample after absorption of the excitation laser. This method can be implemented in a broad spectral range (100 eV to 20 keV) and is only minimally invasive to an existing setup.
    Description: A new concept for temporal gating of synchrotron X‐ray pulses based on laser‐induced thermal transient gratings is presented.
    Keywords: 548 ; synchrotron ; time‐resolved ; thermal deformation ; transient grating ; pulse picking
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2021-07-01
    Description: Vibrio species play a crucial role in maintaining the carbon and nitrogen balance between the oceans and the land through their ability to employ chitin as a sole source of energy. This study describes the structural basis for the action of the GH20 β‐N‐acetylglucosaminidase (VhGlcNAcase) in chitin metabolism by Vibrio campbellii (formerly V. harveyi) strain ATCC BAA‐1116. Crystal structures of wild‐type VhGlcNAcase in the absence and presence of the sugar ligand, and of the unliganded D437A mutant, were determined. VhGlcNAcase contains three distinct domains: an N‐terminal carbohydrate‐binding domain linked to a small α+β domain and a C‐terminal (β/α)8 catalytic domain. The active site of VhGlcNAcase has a narrow, shallow pocket that is suitable for accommodating a small chitooligosaccharide. VhGlcNAcase is a monomeric enzyme of 74 kDa, but its crystal structures show two molecules of enzyme per asymmetric unit, in which Gln16 at the dimeric interface of the first molecule partially blocks the entrance to the active site of the neighboring molecule. The GlcNAc unit observed in subsite −1 makes exclusive hydrogen bonds to the conserved residues Arg274, Tyr530, Asp532 and Glu584, while Trp487, Trp546, Trp582 and Trp505 form a hydrophobic wall around the −1 GlcNAc. The catalytic mutants D437A/N and E438A/Q exhibited a drastic loss of GlcNAcase activity, confirming the catalytic role of the acidic pair (Asp437–Glu438).
    Description: Crystal structures of a GH20 β‐N‐acetylglucosaminidase from V. campbellii reveal substrate specificity in chitin utilization.
    Keywords: 577.14 ; GH20 β‐N‐acetylglucosaminidase ; chitin recycling ; Vibrio spp ; marine bacteria
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2021-06-30
    Description: ROBL‐II provides four different experimental stations to investigate actinide and other alpha‐ and beta‐emitting radionuclides at the new EBS storage ring of ESRF within an energy range of 3 to 35 keV. The XAFS station consists of a highly automatized, high sample throughput installation in a glovebox, to measure EXAFS and conventional XANES of samples routinely at temperatures down to 10 K, and with a detection limit in the sub‐p.p.m. range. The XES station with its five bent‐crystal analyzer, Johann‐type setup with Rowland circles of 1.0 and 0.5 m radii provides high‐energy resolution fluorescence detection (HERFD) for XANES, XES, and RIXS measurements, covering both actinide L and M edges together with other elements accessible in the 3 to 20 keV energy range. The six‐circle heavy duty goniometer of XRD‐1 is equipped for both high‐resolution powder diffraction as well as surface‐sensitive CTR and RAXR techniques. Single crystal diffraction, powder diffraction with high temporal resolution, as well as X‐ray tomography experiments can be performed at a Pilatus 2M detector stage (XRD‐2). Elaborate radioprotection features enable a safe and easy exchange of samples between the four different stations to allow the combination of several methods for an unprecedented level of information on radioactive samples for both fundamental and applied actinide and environmental research.
    Description: ROBL‐II at ESRF provides four experimental stations to investigate actinides with X‐ray absorption and emission spectroscopy, and with surface, high‐resolution powder, and single‐crystal X‐ray diffractometry.
    Keywords: 549 ; actinides ; EXAFS ; XANES ; HERFD‐XANES ; XAS ; XES ; RIXS ; XRD ; CTR ; RAXR ; surface diffraction
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2021-06-30
    Description: Niobium metal foils were heat‐treated at 900°C under different conditions and in situ investigated with time‐resolved X‐ray absorption fine‐structure (EXAFS and XANES) measurements. The present study aims to mimic the conditions usually applied for heat treatments of Nb materials used for superconducting radiofrequency cavities, in order to better understand the evolving processes during vacuum annealing as well as for heat treatments in controlled dilute gases. Annealing in vacuum in a commercially available cell showed a substantial amount of oxidation, so that a designated new cell was designed and realized, allowing treatments under clean high‐vacuum conditions as well as under well controllable gas atmospheres. The experiments performed under vacuum demonstrated that the original structure of the Nb foils is preserved, while a detailed evaluation of the X‐ray absorption fine‐structure data acquired during treatments in dilute air atmospheres (10−5 mbar to 10−3 mbar) revealed a linear oxidation with the time of the treatment, and an oxidation rate proportional to the oxygen (air) pressure. The structure of the oxide appears to be very similar to that of polycrystalline NbO. The cell also permits controlled exposures to other reactive gases at elevated temperatures; here the Nb foils were exposed to dilute nitrogen atmospheres after a pre‐conditioning of the studied Nb material for one hour under high‐vacuum conditions, in order to imitate typical conditions used for nitrogen doping of cavity materials. Clear structural changes induced by the N2 exposure were found; however, no evidence for the formation of niobium nitride could be derived from the EXAFS and XANES experiments. The presented results establish the feasibility to study the structural changes of the Nb materials in situ during heat treatments in reactive gases with temporal resolution, which are important to better understand the underlaying mechanisms and the dynamics of phase formation during those heat treatments in more detail.
    Keywords: 548 ; in situ EXAFS ; high temperature ; time‐resolved EXAFS ; niobium
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    International Union of Crystallography | 5 Abbey Square, Chester, Cheshire CH1 2HU, England
    Publication Date: 2021-06-28
    Description: Recent developments in cryogenic electron microscopy (cryo‐EM) have enabled structural studies of large macromolecular complexes at resolutions previously only attainable using macromolecular crystallography. Although a number of methods can already assist in de novo building of models into high‐resolution cryo‐EM maps, automated and reliable map interpretation remains a challenge. Presented here is a systematic study of the accuracy of models built into cryo‐EM maps using ARP/wARP. It is demonstrated that the local resolution is a good indicator of map interpretability, and for the majority of the test cases ARP/wARP correctly builds 90% of main‐chain fragments in regions where the local resolution is 4.0 Å or better. It is also demonstrated that the coordinate accuracy for models built into cryo‐EM maps is comparable to that of X‐ray crystallographic models at similar local cryo‐EM and crystallographic resolutions. The model accuracy also correlates with the refined atomic displacement parameters.
    Keywords: 548 ; ARP/wARP ; model building ; cryo‐EM ; model accuracy ; sequence assignment
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...