ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1,354)
  • Fisheries
  • 1990-1994  (1,355)
  • 1990  (1,355)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Environmental biology of fishes 27 (1990), S. 303-308 
    ISSN: 1573-5133
    Keywords: Fish introductions ; Africa ; Cichlids ; Barbus ; Haplochromis ; Lake management ; Fisheries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Synopsis Cyprinid fishes apparently constituted the major part of the original fish fauna in Lake Luhondo, Rwanda, at least until 1934. At that time only three species, all cyprinids, were known from the lake:Barbus neumayeri, a small barbel, very common in the lake (described from the lake asBarbus luhondo) and two larger cyprinid species:Barbus microbarbis andVaricorhinus ruandae. These two large species were probably not very common in the lake. Between 1935 and 1938 some youngTilapia were introduced into Lake Luhondo. Since then and certainly since 1952 the large cyprinids seem to have disappeared completely from the lake. The smallBarbus neumayeri has become extremely rare; at present it survives only in some small tributaries of the lake. In the lake itselfTilapia andHaplochromis species are now the dominant fauna. A survey of the available information is given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 1-13 
    ISSN: 0886-9383
    Keywords: Factor analysis ; Self-modeling curve resolution ; Spectra isolation ; Target transformation factor analysis ; Iterative target transformation factor analysis ; Evolving factor analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: One of the major applications of factor analysis in the chemical literature, self-modeling curve resolution (SMCR), is covered in this review, including a historical account of the methods derived from Lawton and Sylvestre's original method. Papers treating the theory or applications of SMCR are included. Qualitative and quantitative applications are described where appropriate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 47-50 
    ISSN: 0886-9383
    Keywords: Classification ; Pattern recognition ; Preprocessing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Over the past 15 years the linear learning machine has been applied to a large number of chemical problems. The learning machine approach is conceptually simple and does not require knowledge about the statistical distribution of the data. However, there are problems associated with this approach. One problem which has not been investigated is the influence of mislabeled samples on the positioning of the hyperplane in feature space. If a few samples in a data set are incorrectly tagged prior to training (i.e. the samples are labeled as members of class 2 even though they are actually members of class 1), it is still possible using the linear learning machine to achieve a classification success rate of 100% for the training set. However, unfavorable results will be obtained for the prediction set. The magnitude of this effect and its potential implications regarding the proper use of the linear learning machine are discussed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 51-59 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak restoration ; Iterative deconvolution ; Peak resolution ; Non-linear deconvolution ; Super-resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In previous papers Jansson's method was found to be successful at deconvolving severely overlapped gas chromatographic peaks. In the most recent paper the method was evaluated with respect to quantitative accuracy, peak area and retention time repeatability. The problems associated with deconvolving noisy data and some alternatives which can improve the ability of Jansson's method to deconvolve noisy data are discussed. These alternatives include presmoothing the data with a nine-point, third-order polynomial filter and data reblurring. This paper will test these methods on peaks with various degrees of resolution and signal-to-noise ratios.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 61-77 
    ISSN: 0886-9383
    Keywords: Infrared ; Spectroscopy ; Spectrometry ; Retrieval ; Confirmation ; Chemometrics ; Adequate peaks ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the series of analytical techniques for identification of chemical substances, infrared spectrometry presents by far the highest information content. However, the information is most complicated too. It concerns a multitude of band positions, band intensities and band shapes, which, moreover, can be disturbed by matrix and other effects. The high redundancy, however, allows conclusions to be made by a qualitative, subjective procedure.IR is often used to prove the equality between a sample and a reference material, e.g. in quality control of a production process. In forensic control, the question to be answered is mostly not to prove equality, but whether or not the presence of a compound in a sample, e.g. a drug, can be proved. Moreover, testing has to be performed according to objective rules.To fulfil these requirements, a new retrieval algorithm, the ‘Adequate Peaks Search’, is presented. It concerns representing the reference spectra by sets of adequate peak positions and the sample spectrum by a set of all peak positions, whereafter the cross-sections of the sample set and the reference sets are determined. The concept ‘adequate peak’ is defined and criteria have been formulated to evaluate the results into a positive (presence of the analyte is proved) or negative (presence is not proved) conclusion.The detection limit when the Adequate Peaks Search (APS) method was applied was four to seven times lower than that attained by a number of experts.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 79-90 
    ISSN: 0886-9383
    Keywords: PLS ; Three-way matrices ; Calibration ; Residual bilinearization ; Background correction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: When using hyphenated methods in analytical chemistry, the data obtained for each sample are given as a matrix. When a regression equation is set up between an unknown sample (a matrix) and a calibration set (a stack of matrices), the residual is a matrix R.The regression equation is usually solved by minimizing the sum of squares of R. If the sample contains some constituent not calibrated for, this approach is not valid. In this paper an algorithm is presented which partitions R into one matrix of low rank corresponding to the unknown constituents, and one random noise matrix to which the least squares restrictions are applied. Properties and possible applications of the algorithm are also discussed.In Part 2 of this work an example from HPLC with diode array detection is presented and the results are compared with generalized rank annihilation factor analysis (GRAFA).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 91-96 
    ISSN: 0886-9383
    Keywords: Sample size ; Monte Carlo ; Multivariate, normal ; Q-Q plots ; Classification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Because many pattern recognition techniques are predicated on the assumption of mutivariate normal data, Monte Carlo simulation studies were performed to determine the number of samples that are necessary to describe a multivariate normal population adequately. From these studies we have learned that hundreds of samples are required. These results suggest that parametric procedures should only be used to analyze very large data sets.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 97-100 
    ISSN: 0886-9383
    Keywords: Matrix decomposition ; NIPALS ; Principal component ; SIMCA ; PLS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The Non-linear Iterative Partial Least Squares (NIPALS) algorithm is used in principal component analysis to decompose a data matrix into score vectors and eigenvectors (loading vectors) plus a residual matrix. NIPALS starts with some guessed starting vector. The principal components obtained by NIPALS depends on the starting vector; the first principal component could not always be computed. Wold has suggested a starting vector for NIPALS, but we have found that even if this starting vector is used, the first principal component cannot be obtained in all cases. The reason why such a situation occurs is explained by the power method. A simple modification of the original NIPALS procedure to avoid getting smaller eigenvalues is presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...