    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 37-42 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The headspace gas in static headspace gas chromatography contains mostly saturated water vapor. In the case of the cryofocusing enrichment technique this may cause baseline distortion in the early part of the chromatogram or may even lead to ice-plugging of the capillary column. A water-trap is described in which the water vapor is removed from the headspace gas before entering the cryo-trap. The water trap is packed with lithium chloride on a porous support and is regenerated after each analysis by heating under backflush conditions. It therefore can be used for automatic operation. Data are given for the precision and accuracy, and some practical examples, for environmental and flavor analysis are shown.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 59-61 
    ISSN: 0935-6304
    Keywords: Steam chromatography ; Salt-water stationary phases ; Retention of alcohols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. iii 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 27-31 
    ISSN: 0935-6304
    Keywords: Test for fused silica surfaces ; Polarity of fused silica surfaces ; Adsorptivity of fused silica surfaces ; Leaching of fused silica ; Stability of fused silica precolumns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Split injection of 1-pentanol headspace on to raw or treated fused silica tubing yields information on the characteristics of its surface (silanol concentration, polarity, adsorptivity). Fused silica tubing from three sources was compared. The effect of various leaching and etching procedures used for column preparation was studied, as was the stability of uncoated fused silica precolumns towards water and some organic solvents.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 32-36 
    ISSN: 0935-6304
    Keywords: Alumina PLOT column ; Column selectivity ; Hydrocarbon gases ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Alumina-coated porous layer open tubular (PLOT) columns are widely used for analyses of light hydrocarbons (C1 to C6). There is, however, a need for improved selectivity for complex analyses such as the determination of impurities in high purity petrochemical products. Some commercial alumina PLOT columns do not have sufficient selectivity for such analyses. The selectivity of four commercial alumina PLOT columns is evaluated for analyses of propylene and ethylene, and differences in column selectivity discussed. Requirements of column selectivity and retention are presented for several applications including the analysis of refinery gas, transformer oil gas, and fuel gas.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 49-53 
    ISSN: 0935-6304
    Keywords: Polycyclic aromatic sulfur heterocycles ; Crude oil ; Oil maturity ; Fingerprinting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is presented for the identification and quantification of C2-substituted benzothiophenes in crude oil. The method will enable analysis of the pattern of these compounds, for example as a basis for differentiating crude oils from one another (fingerprinting) and for investigation of their suitability as indicators of oil maturity. Here results are reported for five crudes from Iraq, Venezuela, Saudi Arabia, the former Soviet Union, and the North Sea. The aromatic fraction of the crudes was oxidized and the dioxides of the heterocycles separated according to the number of carbon atoms in the side chains. The final separation was by capillary GC with atomic emission or flame ionization detection. A fluorinated analog was synthesized and used as internal standard. The concentrations of 2,3-, 2,4-, 2,7-, and 3,7-dimethylbenzothiophene ranged between 11 and 272 ppm. Three other dimethylated benzothiophenes present in lower amounts were also identified.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 143-150 
    ISSN: 0935-6304
    Keywords: Capillary zone electrophoresis ; Cyclodextrin ; Aromatic carboxylic acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method using capillary zone electrophoresis has been developed for separation of a series of isomeric benzene polycarboxylic acids. The separation was found to depend largely on the geometry of the acids and their degree of ionization as well as on the buffer pH and composition. The presence of additives to the buffer such as cyclodextrin and cationic surfactants was found necessary for complete resolution of all the isomers.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 161-164 
    ISSN: 0935-6304
    Keywords: L-2-Hydroxyglutaric acid ; L-2-Hydroxyglutaric aciduria ; Chiral HRGC ; Chiral liquid phases ; Cyclodextrins ; 1(R)-trans-N-N'-1,2-cyclohexenylbisbenzamideoligosiloxane ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: L-2-Hydroxyglutaric aciduria is a recently discovered inherited neurometabolic disease for which diagnostic identification of the right enantiomer is required. A method is described where alkyl esters of both L-and D-2-hydroxyglutaric acids are prepared without side lactonization. Esterification is achieved at room temperature by reaction with appropriate alkyl chloroformates. This method avoids lactonization, in contrast to esterification with alcohols in acidic media or with diazomethane. The identity of the derivatives is established by HRGC-FTIR and HRGC-MS. Chiral HRGC separation with capillaries coated with 1(R)-trans-N-N'-1,2-cyclohexylenebisbenzamideoligodimethyL-siloxane and with a cyclodextrin is compared. The method is adequate for quantitative determinations.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 165-168 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Liquid chromatography ; Solvent venting ; Cholesterol ; Pig fat ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two methods for determination of cholesterol in fat and muscle of pig were evaluated: extraction with chloroform:methanol (2:1, v/v) followed by saponification (method 1) and direct saponification (method 2). HPLC and GC were used to determine cholesterol concentrations. GC analysis was performed with a capillary column of 100 μm using a PTV injector in the modes of cold split and solvent venting. Cholesterol was analyzed without derivatization. Both methods of extraction did not present significant differences (p 〉 0.01). Sample analysis by GC with solvent venting injection and HPLC showed the lowest % r.s.d. but GC in the cold split mode allowed to obtain a shorter analysis time. Cholesterol concentrations obtained by HPLC were not statistically different from the results obtained by GC with solvent venting injection and were slightly lower than those previously reported. Cholesterol concentrations in fat and muscle tissues respectively ranged from 52 to 77 mg/100 g and from 55 to 65 mg/100 g.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource