ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1,315)
  • 1990-1994  (1,315)
  • 1994  (1,315)
Collection
Publisher
Years
  • 1990-1994  (1,315)
Year
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 21-36 
    ISSN: 0886-9383
    Keywords: GRAM ; Tucker ; Unfold ; NBRA ; Second-order ; Three-way ; PARAFAC ; Trilinear ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: If an analytical instrument or instrumental method gives a response matrix when analyzing a pure analyte, the instrument or instrumental method is called a second-order method. Second-order methods that generate a response matrix for a pure analyte of rank one are called rank-one second-order methods. If the response matrix of a pure analyte is not rank one, essentially two cases exist: medium rank (between two and five) and high rank (greater than five). Subsequently, medium- and high-rank second-order calibration tries to use medium- and high-rank second-order methods to analyze for analytes of interest in a mixture. A particular advantage of second-order methods is the ability to analyze for analytes of interest in a mixture which contains unknown interferences. Keeping this advantage is the challenge on moving away from rank-one second-order calibration methods. In this paper a medium-rank second-order calibration method is proposed based on least-squares restricted Tucker models. With this method the second-order advantage is retained.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 101-101 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 103-110 
    ISSN: 0886-9383
    Keywords: Taguchi ; Robust design ; Design of experiments ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper is intended to convey the essence of Taguchi's design approach to chemists and others with an interest in chemometrics. Although most Taguchi-style applications worldwide have been in electronics and in elaborately transformed manufactures, examples are increasingly found in chemical processes and in the food industry.Foremost among Taguchi's contributions is the concept of designing processes and products to be robust to the uncontrollable environmental influences which they experience during their operation or lifetime. This concept is explained with a worked example.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 127-145 
    ISSN: 0886-9383
    Keywords: Compression ; Multivariate analysis ; B-splines ; FT-IR spectra ; Second-order ; Two-dimensional ; Hyphenated methods ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In order to improve the storage and CPU time in the numerical analysis of large two-dimensional (hyphenated, second-order) infrared spectra, a data-preprocessing technique (compression) is presented which is based on B-splines. B-splines have been chosen as the compression method since they are wellsuited to model smooth curves. There are two primary goals of compression: a reduction of file size and a reduction of computation when analyzing the compressed representation. The compressed representation of the spectra is used as a substitute for the original representation. For the particular example used here, approximately 0.16 bit per data element was required for the compressed representation in contrast with 16 bits per data element in the uncompressed representation. The compressed representation was further analysed using principal component analysis and compared with a similar analysis on the original data set. The results shows that the principal compotent model of the compressed representation is directly comparable with the principal component model of the original data.
    Additional Material: 17 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 181-203 
    ISSN: 0886-9383
    Keywords: RAFA ; GRAM ; Eigenvalues ; Bias ; Variance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rank annihilation factor analysis (RAFA) is a method for multicomponent calibration using two data matrices simultaneously, one for the unknown and one for the calibration sample. In its most general form, the generalized rank annihilation method (GRAM), an eigenvalue problem has to be solved. In this second paper expressions are derived for predicting the bias and variance in the eigenvalues of GRAM. These expressions are built on the analogies between a reformulation of the eigenvalue problem and the prediction equations of univariate and multivariate calibration. The error analysis will also be performed for Lorber's formulation of RAFA. It will be demonstrated that, depending on the size of the eigenvalue, large differences in performance must be expected. A bias correction technique is proposed that effectively eliminates the bias if the error in the bias estimate is not too large. The derived expressions are evaluated by Monte Carlo simulations. It is shown that the predictions are satisfactory up to the limit of detection. The results are not sensitive to an incorrect choice of the dimension of the factor space.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 243-243 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0886-9383
    Keywords: Fitting ; Non-linear ; Least squares ; Refinement ; Constraints ; MSE ; Confidence ; C ls ; XPS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A non-linear least squares iterative refinement has been implemented which shows high performance on a multiple-peak spectrum including baseline or background. Constraints as well as links within a range are introduced to drive the mathematical optimization: each peak parameter (i.e. height, position, Gaussian/Lorentzian mixing ratio and HWHM on both left and right sides) has assigned to it an allowed range of variation and can be strained to be correlated with other parameters belonging either to the same peak (symmetrical peaks) or to other peaks (doublets, triplets, etc.). Peak shapes typical of XP spectra are used and applications in the field of XPS are discussed. Through emulated curves with Poisson distributed noise, the accuracy and precision of back-calculated (refined) parameters have been estimated. Moreover, a confidence level calculated from X2 and degrees of freedom has been suggested to check the overall fitting of experimental curves where the signal-to-noise ratio is a priori unknown. An application to real C ls XP spectra is described as an example and a list of suggestions is given to match operator requirements. Finally, features of NLLSRC are discussed with respect to other approaches.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 263-272 
    ISSN: 0886-9383
    Keywords: Molecular descriptors ; Principal component analysis ; Chemometrics ; Pattern recognition ; Total surface area ; PCDD PCDF ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New theoretical molecular indices are defined. They contain information about the whole molecular structure in terms of size, shape, symmetry and atom distribution. These indices are calcualted from the (x, y, z) co-ordinates of a molecule within different weighting schemes in a straightforward manner and represent a very general approach to describe molecules, molecular fragments, macromolecules and molecular conformations in a unitary conceptual framework. Their interpretability is quite evident and is defined by the same mathematical properties as the algorithm used for their calculation. Examples on the total surface area, toxicity of PCDD and PCDF and reaction rate of catalysed reactions show a high modelling power of these indices.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...