ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Gas chromatography  (72)
  • Wiley-Blackwell  (57)
  • Springer  (15)
  • 1980-1984  (72)
  • 1980  (72)
  • 1
    ISSN: 1432-0878
    Keywords: Preputial glands ; Nude mice ; Ultrastructure ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary The preputial glands of male nude (nu/nu) mice were analyzed by a combination of electron microscopy and gas chromatography to determine whether or not they are affected, like developing hairs and nails, by the nu/nu genotype. Results of the analyses revealed no differences between the glands of nude and normal male mice in either their ultrastructural characteristics or lipid secretory products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 203-206 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Carrier gas purity ; Sample stability
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The amount of oxygen which may be present in the gas volume corresponding to a peak is investigated and compared to the sample amounts. It is shown that even with high purity carrier gases one may have a significant excess of oxygen present at low sample amounts. Attention is drawn to the possibility of impurity build-up by diffusion e.g. through the septum.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 263-270 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Metal complexes ; Enantiomers ; Isotopic composition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The high selectivity of complexation gas chromatography has been employed for enantiomer resolution and isotope separation. Thus, a chiral olefin, 3-methylcyclopentene, has been resolved analytically on optically active dicarbonyl-rhodium(I)-3-trifluoroacetyl-1R-camphorate in squalane. The deuterated ethylenes C2H4−nDn have been separated on the same rhodium(I)-containing stationary phase. The chiral aliphatic oxiranes epoxypropane andtrans-2,3-epoxybutane have been resolved on optically active nickel(II)-bis-3-trifluoroacetyl-1R-camphorate in squalane.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Gas chromatography ; On-column abstraction ; Aliphatic aldehydes ; Amine antioxidants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The selective on-column abstraction of aliphatic aldehydes by gas chromatographic stationary phases containing N-iso-propyl N′-phenyl-p-phenylenediamine is described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 35-39 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Nitromethane ; Nitroalkanes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Impurities in commercially available nitromethane have been determined by gas-liquid chromatography using six different column packings. Besides nitromethane, 1-nitropropane, 2-nitropropane, acetonitrile, methanol, small amounts of ethanol and acetaldehyde have been detected. The presence of formaldehyde, ethyl acetate and acetone is probable. Mixtures containing comparable amounts of the four nitroalkanes could be separated on all columns, but plots of logarithms of the retention times vs. carbon number or boiling points of the nitroalkanes or column temperatures were linear only in case of columns packed with Porapak R and Q.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 686-692 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Micropacked columns in GC ; Microparticles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Porous silica microparticles designed for modern liquid chromatography have proven effective in gas chromatography. Columns of 35–50 cm gave plate heights as low as 3.3 particle diameters and speeds of 2400 theoretical plates per second or 500 effective theoretical plates per second. Inlet pressures up to 70 atmospheres were required using hydrogen as carrier gas. The particles as received were too retentive for fast chromatography and gave asymmetric peaks. A coating of fluorosilicone oil overcame both problems. Other coatings were less effective. Bonded phases proved less satisfactory on both counts and also gave substantially less efficient columns and greater flow resistance. Column efficiency and flow resistance were sharply dependent on physical properties of the particles. The most efficient packing was clearly spherical particles of 5–10 μm diameter with narrow size distribution, pore diamters about 50 nm, BET surface areas of 25–50 m2/g and surfaces modified with trifluoropropyl silicone. A six-component hydrocarbon sample was separated in 33 s with a resolution of 4 for the most difficult pair and in 2.6 s with a minimal resolution. Performance was limited by end effects and by available pressure so that much better performance can be expected from longer columns and higher pressures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 752-754 
    ISSN: 1612-1112
    Keywords: Xylenol isomers ; Gas chromatography ; Polyols and polyethers as stationary phase ; Hydrogen bonding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Xylenol isomers can be resolved on most polyols (sugars or sugar alcohols) and polyethers (polyethylene glycol or polypropylene glycol) with hydrogen-bonding interaction. They are separated on vinical polyols which have more hydroxy hydrogen than tetrol, and even on vicinal triol when its hydroxy hydrogen is acidic (stronger proton donor). The stronger is the hydrogen bonding interaction between xylenols and the liquid phase, the better is the separation of 2,4- and 2,5-xylenol, and the poorer the separation of 2,4-and 2,3-xylenol.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 651-660 
    ISSN: 1612-1112
    Keywords: Capillary columns, glass ; Gas chromatography ; Column preparation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Glass capillary column chromatography is the most rapidly growing part of gas chromatography. There are many complex new analytical tasks and they require special capillary columns. Fortunately there is a wide range of column preparation methods available, and they make the preparation of glass capillary columns a more varied job than that of packed columns. In this paper these methods are reviewed and suggestions are given for making task-oriented columns.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 13 (1980), S. 73-84 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Gas hold-up time ; Dead time
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The two approaches used for the calculation of the gas hold-up time and thus, the adjusted retention time are outlined, first for the restricted case when the carbon numbers of the three homologues used for the calculation are evenly spaced (c3−c2=c2−c1) and then, for the general case when (c3−c2) differs from (c2−c1). The basic difference in the philosophy of the two approaches is shown.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Column characterization ; Oxidation ; Stationary phases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The on-column oxidation of hydrocarbons commonly used as stationary phases in column characterization is investigated. In each case significant shifts of retention are observed, which may be negative or positive depending upon the polarity of the test solutes and the adsorptivity of the support material. In order to reduce the consequent uncertainties in the Rohrschneider [1] and McReynolds [2] polarity values, a new method of column characterization is proposed. The applicability of the new method is illustrated by a consideration of a range of silicone liquid phases.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...