ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (407,118)
  • Articles: DFG German National Licenses  (407,118)
  • Chemistry  (407,118)
Collection
  • Articles  (407,118)
Source
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular evolution 15 (1980), S. 79-101 
    ISSN: 1432-1432
    Keywords: Molecules ; Interstellar ; Chemistry ; Isotopes ; Solar system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary The study of interstellar molecules broadly includes two areas of interest. One area uses the unique ability of molecules to act as probes of the physical conditions in the cold, dense, visually opaque component of the interstellar medium. The physical properties of this and other components of the interstellar medium are summarized. The other area deals with the chemistry of interstellar molecules, recent aspects of which are emphasized in this review. Gas-phase chemistry, shock chemistry, and grain surface chemistry are discussed in the context of recent observations. No present observations suggest that surface reactions are relevant, but neither can they be ruled out. Ion-molecule reactions are clearly operative, at least for the simpler species. Chemical isotope fractionation is reviewed, andd it is concluded that the complexities of the chemistry allow no cosmological conclusions to be drawn from observations of deuterium in interstellar molecules, while the presence of13C in interstellar molecules permits an estimate of the12C/13C ratio which is consistent with the current concepts of the nucleosynthesis history of the Galaxy. Possible connections between interstellar molecules and the early molecular history of the solar system are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Inorganica Chimica Acta 226 (1994), S. 293-340 
    ISSN: 0020-1693
    Keywords: Chemistry ; Electrochemistry ; Electron transfer ; Metalloproteins ; Redox reactions
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 39-44 
    ISSN: 1432-0827
    Keywords: Dental cementum ; Collagen ; Protein ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Cyanogen bromide (CNBr) peptides were prepared of the insoluble collagen of bovine dental cementum. Following chromatographic separation, the peptides were identified by their amino-acid composition. Type I collagen ([α1(I)]2α2) accounted for more than 90% of the organic matrix, while Type III collagen ([α1(III)]3) was present at a level of approximately 5%. Amino-acid analyses revealed that the CNBr peptides from α1(I) and α2 chains of cementum closely resembled the corresponding peptides from calf skin. The only systematic difference was a higher level of hydroxylation of prolyl and lysyl residues of the cementum peptides.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 7 (1971), S. 150-162 
    ISSN: 1432-0827
    Keywords: Uranium ; Bone ; Distribution ; Fission ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Une concentration moyenne de 2.4×10−8 g U/g de cendre a été obtenue à partir de l'os humain normal. La microdistribution de l'uranium dans l'os indique que cet élément est surtout limité à surface de l'endoste et, en particulier, aux surfaces de l'os lamellaire et aux parois des canaux de Havers, ouverts dans l'os corticol. Cette répartition suggère que l'uranium se présente sous une forme chimique impropre à son incorporation dans l'apatite osseux: il ne semble donc pas exister une distribution diffuse significative de l'uranium dans l'os.
    Abstract: Zusammenfassung Eine mittlere Konzentration von 2,4×10−8 g Uran/g Asche wurde in normalen menschlichen Knochen gefunden. Die Feinverteilung von Uran im Knochen zeigt, daß dieses Element hauptsächlich an der endostalen Oberfläche vorkommt, insbesondere an der Oberfläche des trabeculären Knochens und an den Wänden der offenen Haversschen Kanäle im kortikalen Knochen. Diese Verteilung läßt vermuten, daß Uran in einer chemischen Form vorliegt, welche sich für den Einbau in das Knochenapatit nicht eignet. Daraus folgt, daß keine signifikante diffuse Verteilung des Urans innerhalb des Knochens vorliegt.
    Notes: Abstract A mean concentration of 2.4×10−8 g U/g ash has been obtained for normal human bone The microdistribution of uranium in bone indicates that this element is mainly restricted to endosteal surfaces; in particular the surfaces of trabecular bone and the walls of open Haversian canals in cortical bone. This distribution suggests that uranium is present in a chemical form that is not acceptable for incorporation into bone apatite and consequently there does not appear to be a significant diffuse distribution of uranium throughout bone.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0827
    Keywords: Morphology ; Glycosaminoglycans ; Cartilage ; Chemistry ; Audioradiography ; Healing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Une perte de substance ostéo-cartilagineuse, de taille limitée et identique, est réalisée chez le lapin adulte et la cicatrisation est étudiée histologiquement et par autoradiographie après marquagein vitro au35S-sulfate. Une analyse microchimique est pratiquée pour le contenu et la composition en glycosaminoglycanes. 1. Entre la première semaine et la 4ème et 8ème semaine, un tissu conjonctif non-métachromatique se différencie en un cartilage métachromatique et la quantité de sulfate de chondroitine augmente de façon significative aux dépens des glycoprotéines. 2. Jusqu'à la 4ème semaine, la perte de substance est surtout comblée par de l'os néoformé: après cette période, la région est comblée au delà de la limite de la surface articulaire. 3. Le cartilage hyalin, ressemblant morphologiquement, autoradiographiquement et chimiquement au cartilage articulaire, en ce qui concerne la distribution en glycosaminoglycanes, constitute la surface articulaire de la perte de substance comblée dans un tiers des cas après 8 semaines. Le cartilage hyalin s'observe surtout dans les régions où de l'os néoformé a comblé la cavité médullaire. 4. Dans les deux tiers des cas, après 8 semaines, les surfaces articulaires des zones comblées comportent, non seulement du cartilage, mais aussi du tissu fibreux se formant essentiellement sur les parties latérales et dans les régions, où la cavité médullaire, fliant face, à la surface articulaire, n'a pas été comblée par du tissue osseux. La fraction glycoprotéique augmente par rapport à la fraction chondroitine sulfate. 5. Dans la majorité des cas, après 20 semaines, le cartilage néoformé subit des phénomènes dégénératifs, qui se traduisent par une diminution en chondroitine sulfate.
    Abstract: Zusammenfassung Bei ausgewachsenen Kaninchen wurde ein begrenzter, standardisierter, osteochondraler Defekt hervorgerufen, und das regenerierte Gewebe wurde histologisch und autoradiographisch durch Markierung in vitro mit35S-Sulfat und durch mikrochemische Bestimmung des Gehaltes und der Zusammensetzung der Glykosaminglykane untersucht. Die wichtigsten Befunde waren: 1. Zwischen 1 und 4–8 Wochen veränderte sich nichtmetachromatisches Bindegewebe zu metachromatisch gefärbtem Knorpel, und der Anteil an Chondroitin-Sulfat nahm auf Kosten der Glykoproteine signifikant zu. 2. Bis zu 4 Wochen war der Hauptteil des defekten Gebietes mit neugebildetem Knochen gefüllt; nach dieser Zeit lag dieser Bezirk oberhalb der Verknöcherungsgrenze in Richtung der Gelenkoberfläche. 3. Nach 8 Wochen bestand die Gelenkoberfläche des defekten Gebietes in einem Drittel der Fälle aus hyalinem Knorpel, der morphologisch, autoradiographisch und chemisch dem Gelenkknorpel in Bezug auf die Verteilung von Glykosaminoglykanen glich. Hyaliner Knorpel wurde hauptsächlich an Stellen beobachtet, wo neugebildeter Knochen die Markhöhle geschlossen hatte. 3. Nach 8 Wochen bestand die Gelenkoberfläche des defekten Gebietes in einem Drittel der Fälle aus hyalinem Knorpel, der morphologisch, autoradiographisch und chemisch dem Gelenkknorpel in Bezug auf die Verteilung von Glykosaminoglykanen glich. Hyaliner Knorpel wurde hauptsächlich an Stellen beobachtet, wo neugebildeter Knochen die Markhöhle geschlossen hatte. 4. Nach 8 Wochen bestanden Teile der Gelenkoberfläche des Defektes in zwei Dritteln der Fälle nicht nur aus Knorpel, sondern auch aus fibrösem Gewebe, welches vor allem in den seitlichen Teilen des Defektes und an Stellen vorlag, wo die Markhöhle gegenüber der Gelenkoberfläche nicht mit Knochengewebe verschlossen worden war. Die Glykoproteinfraktion nahm im Vergleich zur Chondroitin-Sulfatfraktion zu. 5. Nach 20 Wochen zeigten sich in den meisten Fällen bei neugebildetem Knorpel degenerative Veränderungen, welche durch eine gewisse Abnahme des Chondroitin-Sulfats wiedergegeben wurden.
    Notes: Abstract A limited, standardized osteochondral defect was created in adult rabbits and the regenerated tissue was examined histologically and autoradiographically after labellingin vitro with35S-sulphate, and microchemically for its content and composition of glycosaminoglycans. The principal findings were: 1. Between 1 week and 4 to 8 weeks, non-metachromatic connective tissue differentiated to metachromatically stained cartilage, and the proportion of the chondroitin sulphate increased significantly at the expense of the glycoproteins. 2. Up to 4 weeks, the major part of the defect area was filled with newly formed bone; after this time, the area lay above the level of the “tidemark”, towards the articular surface. 3. Hyaline cartilage with morphological, autoradiographic and chemical resemblance to the articular cartilage in terms of the distribution of glycosaminoglycans constituted the articular surface of the defect area in one-third of the cases at observation times after 8 weeks. Hyaline cartilage was observed mainly in areas where newly formed bone had closed the medullary cavity. 4. In two-thirds of the cases, after 8 weeks, parts of the articular surface of the defect consisted not only of cartilage but also of fibrous tissue, occurring mainly in the lateral parts of the defect and in areas where the medullary cavity facing the articular surface had not been sealed by bone tissue. The glycoprotein fraction increased relative to the chondroitin sulphate fraction. 5. In most cases after 20 weeks, newly-formed cartilage underwent degenerative changes, which were reflected in some reduction of the chondroitin sulphate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 10 (1972), S. 82-90 
    ISSN: 1432-0827
    Keywords: Calcium ; Phosphate ; Precipitation ; Kinetics ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé La cinétique de la formation et de la transformation des précipités de phosphate de calcium, obtenus en mélangeant de volumes égaux de solutions à 6×10−3 M de calcium total et/ou phosphate total est étudiée à 25°C. Les solutions de phosphate sont préajustées à un pH de 7.4. Les changements de pH et de turbidité des solutions sont suivis simultanément en fonction du temps. Les précipités sont isolés à des intervalles de temps variables et caractérisés par diverses méthodes physico-chimiques. Initialement un précipité avec un rapport molaire Ca/P de 1.5, amorphe aux rayons X et en diffraction électronique, est formé. Le spectre IR indique la présence de PO 4 3− et de HPO 4 2− . Après une période métastable, on observe la précipitation d'un matériel cristallin dans ou sur la phase amorphe. Vingt quatre heures après préparation de l'échantillon les précipités présentent surtout les caractères du phosphate octocalcique.
    Abstract: Zusammenfassung Die Kinetik der Bildung und Transformation von Calciumphosphat-Niederschlägen wurde bei 25°C untersucht. Es wurden dazu gleiche Volumen von Lösungen gemischt, bei einer Konzentration von 6×10−3M totales Calcium und/oder totales Phosphat. Die Phosphatlösungen wurden zuerst auf pH 7,4 eingestellt. Veränderungen des pH und Trübung der Lösungen wurden gleichzeitig als eine Funktion der Zeit aufgezeichnet. Niederschläge wurden in verschiedenen Zeitintervallen isoliert und mit verschiedenen physiko-chemischen Methoden charakterisiert. Am Anfang wurde ein Niederschlag mit einem molaren Ca/P-Verhältnis von 1,5, im Röntgenbild und in der Elektronendiffraktion amorph, gebildet. Infrarotspektren deuteten die Anwesenheit von PO 4 3− - und HPO 4 2− -Ionen an. Nach einer metastabilen Periode erfolgte ein Niederschlag aus kristallinem Material innerhalb oder auf der amorphen Substanz. 24 Std nach der Herstellung der Proben zeigten die Niederschläge in der Hauptsache die Charakteristiken von Octocalciumphosphat.
    Notes: Abstract The kinetics of the formation and transformation of calcium phosphate precipitates obtained by mixing equal volumes of solutions, 6×10−3 M in total calcium and/or total phosphate was investigated at 25°. The phosphate solutions were preadjusted to pH 7.4. Changes of the pH and turbidity of the solutions were followed simultaneously as a function of time. Precipitates were isolated at various time intervals and characterized by different physicochemical methods. Initially a precipitate with a molar Ca/P ratio of 1.5, amorphous to X-ray and electron diffraction was formed. IR spectra indicated the presence of PO 4 3− and HPO 4 2− ions. After a period of metastability, precipitation of a crystalline material within or upon the amorphous matter occurred. Twenty four hours after sample preparation the precipitates showed mainly the characteristics of octacalcium phosphate.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 14 (1974), S. 3-14 
    ISSN: 1432-0827
    Keywords: Hydroxyapatite ; Mineral ; Phase ; Chemistry ; Synthesis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Des diagrammes de phase d'équilibre ont été déterminés pour le système CaO-P2O5-H2O en utilisant des techniques de synthèse hydrothermique au cours de variatio nsde température allant de 300–600° et 2 Kb H2O de pression. De l'hydroxyapatite bien cristallisé a été synthétisé et caractérisé. De faibles variations de paramètres de la maille cristalline, liées à la température de synthèse et composition globale du matériel initial, ont été déterminées. Des conditions chimiques précises sont nécessaires pour obtenir de l'apatite, en tant que seule phase solide en équilibre dans la solution. Les résultats de diagramme de phase d'équilibre sont comparés avec ceux obtenus dans des milieux synthétiques.
    Abstract: Zusammenfassung Es wurden Gleichgewichts-Phasendiagramme für das System CaO-P2O5-H2O bestimmt, indem hydrothermale Synthese-Techniken im Temperaturbereich von 300–600° und bei einem Druck von 2 Kb H2O verwendet wurden. Es wurde gut-kristallisiertes Hydroxyapatit erzeugt und charakterisiert. Es wurden geringe Unterschiede in den Parametern der Zelleinheiten festgestellt, welche von der angewandten Temperatur und der Zusammensetzung des Startmaterials abhingen. Es waren genaue chemische Bedingungen nötig, um Apatit als die einzige feste Phase im Gleichgewicht mit der Lösung zu erhalten. Die Resultate der Gleichgewichts-Phasendiagramme werden mit früheren Untersuchungen mit der Synthesetechnik verglichen.
    Notes: Abstract Equilibrium phase diagrams have been determined for the system CaO-P2O5-H2 using hydrothermal synthesis techniques in the temperature range 300–600° and 2 Kb H2O pressure. Well-crystallized hydroxyapatite has been produced and characterized. Small variations in unit cell parameters dependent on temperature of synthesis and bulk composition of the starting materials have been determined. Precise chemical conditions were required to obtain apatite as the only solid phase in equilibrium with solution. Equilibrium phase diagram results are compared with previous synthetic investigations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 13 (1973), S. 259-270 
    ISSN: 1432-0827
    Keywords: Fluorapatite ; Exchange ; Chemistry ; Crystallography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Un échantillon minéral provenant de Burgess, Canada s'est révélé être un speciment exceptionnellement pur de fluoroapatite après analyse chimique et cristallographique. La composition globale de cet échantillon est la suivante: $$(Ca^2 )9.98(Sr^{2 + } ,Na^ + ,K^ + ,Mg^{2 + } )0.02(PO_4^{3 - } )5.98(HCO_3^ - ,CO_3^{2 - } )0.02(F^ - )2$$ . L'axe cristallographique C est de 6.865 A et l'axe a de 9.374 A. Des expériences d'échanges réalisés à l'aide de45Ca,32P et18F indiquent la présence de gros cristallites de surface spécifique de l'ordre de 1 m2/g. Il apparait que l'interprétation physique des processus d'échange ne nécessite pas l'existence de compartiments séparés, avec chacun son propre facteur cinétique, les échanges semblent être simplement liés à un changement exponentiel dans l'énergie libre de la réaction. Pour la réaction suivante: $$(Ca)_5 (PO_4 )_3 OH solide + (F^ - ) \rightleftarrows (Ca)_5 (PO_4 )_3 F solide + (OH^ - )$$ , la constante thermodynamique de 101.26 a été calculée, suggérant que le fluorapatite se forme toujours aux dépens de l'hydroxyapatite dans des conditions physiologiques. Cette transformation se continue en abaissant le pH.
    Abstract: Zusammenfassung Eine Mineralprobe aus Burgess, Kanada, erwies sich nach chemischer und kristallographischer Analyse als außergewöhnlich reines Fluorapatit. Die Gesamtzusammensetzung entspricht: $$(Ca^{2 + } )_{9,98} (Sr^{2 + } ,Na^ + ,K^ + ,Mg^{2 + } )_{0,02} (PO_4^{3 - } )_{5,98} (HCO_3^ - ,CO_3^{2 - } )_{0,02} (F^ - )_2 $$ . Die kristallographische c-Achse wurde bestimmt und ergab 6,865 Å, und die a-Achse ergab 9,374 Å. Austauschwerte, welche durch Anwendung von45Ca,32P und18F erhalten wurden, deuteten auf große Kristalliten mit einer spezifischen Oberfläche von ca. 1 m2/g. Die Befunde deuten darauf hin, daß für die physikalische Erklärung des Austauschvorganges keine separaten Kompartimente mit eigenen kinetischen Faktoren nötig sind, sondern daß der Austausch mit dem exponentiellen Wechsel in der freien Energie der Reaktion in einfacher Beziehung steht. Für die Reaktion $$(Ca)_5 (PO_4 )_3 OH_{in fester Form} + (F^ - ) \rightleftarrows (Ca)_5 (PO_4 )_3 F_{in fester Form} + (OH^ - )$$ wurde als thermodynamische Konstante 101,26 errechnet, was darauf deutet, daß unter physiologischen Bedingungen immer Fluorapatit auf Kosten von Hydroxyapatit entsteht. Diese Umwandlung wird erhöht, wenn das pH erniedrigt wird.
    Notes: Abstract A mineral specimen from Burgess, Canada, proved upon chemical and crystallographic analyses to be an exceptionally pure sample of fluorapatite. The over-all composition corresponds to $$(Ca^{2 + } )_{9.98} (Sr^{2 + } ,Na^ + ,K^ + ,Mg^{2 + } )_{0.02} (PO_4^{3 - } )_{5.98} (HCO_3^ - ,CO_3^{2 - } )_{0.02} (F^ - )_2 $$ . The crystallographic c-axis was determined to be 6.865 Å, and the a-axis 9.374 A. Exchange data obtained by employing45Ca,32P, and18F indicate the presence of large crystallites with a specific surface of the order of 1 m2/g. It is indicated that the physical interpretation of the exchange process does not require the existence of separate departments, each with its own kinetic factor, but that the exchange may be simply related to the exponential change in the free energy of the reaction. For the reaction $$(Ca)_5 (PO_4 )_3 OH_{solid} + (F^ - ) \rightleftarrows (Ca)_5 (PO_4 )_3 F_{solid} + (OH^ - )$$ the thermodynamic constant has been calculated to be 101.26, implying that fluorapatite always will form at the expense of hydroxyapatite under physiologic conditions. This transformation will be furthered by lowering the pH.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 87-94 
    ISSN: 1432-0827
    Keywords: Calcium ; Osteoporosis ; Lactation ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The calcium homeostatic mechanism was challenged in adult female rats by feeding them a calcium-deficient diet containing oxalate, and by subjecting them to pregnancy and lactation. The regimen caused a substantial weight loss, especially in those animals which reared their young well. Severe hypocalcaemia was observed in the lactating rats. Serum-P was slightly elevated. The content of hydroxyproline in serum was considerably elevated, reflecting the degree of calcium deprivation. Serum proteins were least influenced. The calcium depriving regimen reduced the growth of long bones, but did not stop it. The ash content of the bones was considerably reduced, the degree of reduction depended on the degree of calcium deprivation. Ash as percentage of total bone organ was reduced, but not to the same extent as total ash. Analyses of different parts of femur showed that the proximal and distal parts had lost more bone mineral than the diaphyseal shaft. The ash content of cortical bone tissue from the femur was estimated by a volumetric method. No differences were observed between test groups and controls, indicating that no measurable amounts of bone mineral had been removed from the walls of the vascular canals or by osteocytic osteolysis. Planimetric determinations on cross sections from femora disclosed that a great amount of bone had been removed from the endosteal surface of the diaphysis, while the periosteal surface demonstrated reduced bone apposition.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 12 (1973), S. 125-136 
    ISSN: 1432-0827
    Keywords: Mineralization ; Molt ; Isopod ; Chemistry ; Light microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Au cours de la phase inhabituelle de mue d'un isopode d'eau courante,Lirceuts brachyrus, la moitié postérieure de l'exosquelette est éliminée 24 heures avant la moitié antérieure. A ce stade, une reminéralisation se développe dans la partie postérieure alors que la partie antérieure est dans un stade de pré-mue. Le pourcentage de différence en calcium dans les deux moitiés à mi-mue et mue complète est respectivement de 22% (p〈0.01) et 33% (p〈0.01), indiquant une complexation du calcium pendant la mue. La rapidité de la reminéralisation est illustrée par le fait que le contenu minéral total double dans la partie postérieure entre la mi-mue et la mue totale et dans la partie antérieure entre la fin de la mue et un jour après. Le carbonate de calcium, sous forme de calcite, a pu être identifié par diffraction électronique de coupes fines des téguments.
    Abstract: Zusammenfassung Während der ungewöhnlichen Häutungssequenz des Frischwasser-IsopodenLirceus brachyurus (Harger) wird die hintere Hälfte des äußeren Skeletts 24 Std vor der vorderen Hälfte abgestoßen. In der halbgehäuteten Phase erfolgt Remineralisation im hinteren Teil, während der vordere Teil in einem Vorhäutungszustand ist. Der prozentuale Unterschied des Calciums in den zwei Hälften bei Halb- und Vollhäutungszustand ist 22% (p〈0,01) bzw. 33% (p〈0,01), was andeutet, daß Calcium während der Häutung abgesondert wird. Die Geschwindigkeit der Remineralisation erhellt aus der Tatsache, daß sich der Gesamtmineralgehalt im hinteren Teil zwischen Halt- und Vollhäutung, in der vorderen Hälfte jedoch zwischen Endhäutung und einem Tag nach der Häutung verdoppelt. Calciumcarbonat in kristalliner Calcitform wurde mittels Elektronendiffraktion von dünnen Hautschnitten nachgewiesen.
    Notes: Abstract During the unusual molt sequence of the fresh-water isopod,Lirceus brachyrus (Harger), the posterior half of the exoskeleton is shed 24 hours before the anterior half. At the half-molt stage, occurs in the posterior part while the anterior portion is in a pre-molt condition. The percentage difference in calcium in the two halves at half-molt and full-molt is22 (p〈0.01) and33 (p〈0.01) respectively, an indication that calcium is sequestered during The rapidity of remineralization is illustrated by the fact that the total mineral content doubles in the posterior part between half and full molt and in the anterior half between the end of molt and one day after ecdysis. Calcium carbonate in the calcite cystalline form was demonstrated by electron diffraction of thin sections of the integument.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 16 (1974), S. 145-152 
    ISSN: 1432-0827
    Keywords: EHDP ; Bone ; Chemistry ; Serum ; Rabbits
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Abstract The effects of disodium ethane-1-hydroxy-1,1-diphosphonate (EHDP) on bone and serum chemistry were investigated in adult rabbits. EHDP was administered by subcutaneous injection at doses of 0.25, 2.5 and 10 mg/kg body weight/day for of 28 days. Blood samples were obtained weekly from each rabbit and serum levels of total calcium, ionized calcium, inorganic phosphate and alkaline phosphatase were determined. At the end of the treatment period all rabbits were sacrificed and the tibiae removed for chemical analysis and histological evaluation. The effect of EHDP administration on serum chemistry was both dose- and time-related. The highest of the three doses, 10 mg/kg/day, resulted in a time-related decrease in total serum calcium. This dose also caused a rapid but transient reduction in serum ionized calcium. The effect of EHDP on serum inorganic phosphate was biphasic. Administration of 2.5 mg/kg/day resulted in a time-related elevation in this parameter, whereas the 10 mg/kg/day dose resulted in a time-related hypophosphatemic response. There were no significant drug-related changes in tibial fat-free dry weight, ash weight, total calcium or total phosphorus values. However, administration of 2.5 and 10 mg/kg/day EHDP resulted in increased osteoid tissue as measured histologically. These results are compared with data from other EHDP studies, and discussed in relation to the maturity and growth-state of the experimental animals.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 8 (1971), S. 197-210 
    ISSN: 1432-0827
    Keywords: Fluorescence ; Calcium ; Collagen ; Chemistry ; Bone ; Dentine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Des composants fluorescents de l'os et la dentine sont séparés des hydrolysats alcalins de leur marice sur des colonnes Sephadex C25 CM d'échange cationique. Les concentrations en fluorescence et le spectre d'excitation (λ max 330 nm) et d'émission (λ max 395 nm) sont les mêmes que ceux observés au niveau des matrices intactes et gélatinisées. Les paramètres de fluorescence ne sont pas altérés par hydrolyse. La filtration sur gel à l'aide de colonnes Sephadex G 10 perment de différencier le matériel isolé en deux composants, ayant la même fluorescence et la même absorption UV. La fluorescence est indépendante de pH de 3.5–9.5. Des études de dialyse et de filtration sur gel de matrices gélatinisées indiquent une association étroite du matériel fluorescent avec les chaines polypeptidiques de collagène.
    Abstract: Zusammenfassung Fluorescierende Bestandteile aus Knochen und Dentin wurden in Sephadex C25 CM Kationen-Austauschersäulen von alkalischen Hydrolysaten ihrer Matrices getrennt. Die Fluorescenzintensitäten sowie die Erregungs- (λ max 330 nm) und Emissions- (λ max 395 nm) Spektren waren dieselben wie bei intakten und gelatinisierten Matrices. Die Fluorescenzparameter wurden durch die Hydrolyse nicht verändert. Eine Gelfiltration über Sephadex-G10-Säulen trennte das isolierte Material in 2 Komponenten auf, welche gleiche Fluorescenz- und UV-Absorptionseigenschaften zeigten. Im pH-Bereich zwischen 3,5 und 9,5 war die Fluorescenz unabhängig vom pH. Dialysierversuche sowie Gelfiltrationsexperimente mitden gelatinisierten Matrices zeigten eine starkgefügte Bindung des fluorescierenden Materials mit den Polypeptidketten des Kollagens.
    Notes: Abstract Fluorescent components in bone and dentine were separated from alkaline hydrolysates of their matrices on Sephadex C25 CM cationic exchange columns. The fluorescence levels, and the excitation (λ max 330 nm) and emission (λ max 395 nm) spectra, were the same as those observed in the intact and gelatinised matrices. The fluorescence parameters were unaltered by the hydrolysis procedure. Gel filtration on Sephadex G. 10 columns further resolved the isolated material into two components with the same fluorescence and UV absorption properties. The fluorescence was independent of pH over the range 3.5–9.5. Dialysis and gel filtration studies on the gelatinised matrices indicated a firmly-bonded association of the fluorescent material with the collagen polypeptide chains.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 118 (1980), S. 128-151 
    ISSN: 1420-9136
    Keywords: Galactic cosmic rays ; Solar proton events ; Particle precipitation ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract An assessment is made of the relative contribution of certain classes of energetic particle precipitation to the chemical composition of the middle atmosphere with emphasis placed on the production of odd nitrogen and odd hydrogen species and their subsequent role in the catalytic removal of ozone. Galactic cosmic radiation is an important source of odd nitrogen in the lower stratosphere but since the peak energy deposition occurs below the region where catalytic removal of O3 is most effective, it is questionable whether this mechanism is important in the overall terrestrial ozone budget. The precipitation of energetic solar protons can periodically produce dramatic enhancement in upper stratospheric NO. The long residence time of NO in this region of the atmosphere, where catalytic interaction with O3 is also most effective, mandates that this mechanism be included in future modelling of the global distribution of O3. Throughout the mesosphere the precipitation of energetic electrons from the outer radiation belt (60°≲Λ≲70°) can sporadically act as a major local source of odd hydrogen and odd nitrogen leading to observable O3 depletion. Future satellite studies should be directed at simultaneously measuring the precipitation flux and the concomitant atmosphere modification, and these results should be employed to develop more sophisticated models of this important coupling.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 10 (1972), S. 171-197 
    ISSN: 1432-0827
    Keywords: Amorphous ; Crystalline ; Calcium phosphate ; Chemistry ; Composition
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Des échantillons non lavés de phosphate de calcium amorphe (ACP) contiennent une fraction labile, non remplaçable, riche en phosphate acide avec un rapport Ca/P faible: cette fraction est perdue de façon irréversible au cours du lavage. De l'ACP frais, précipité entre pH 6.6–10.6, varie dans un rapport molaire Ca/P de 1.18 à 1.50 et dans un rapport HPO 4 2− /P total de 33.0% à 10.1%. A pH 7.40, de l'ACP frais a un rapport molaire Ca/P de 1.36±0.02 et contient 22.8 (±2.2)% HPO 4 2− . Les résultats obtenus avec du précipité non lavé ne peuvent s'expliquer par du Ca2+ emprisonné et de l'HPO 4 2− ou du Na+, Cl− et CO 3 2− exogènes. Les phosphates de calcium amorphes constituent une classe de sels ayant des caractères chimiques variables et des propriétés physiques identiques, comparables au verre. Le CaHPO4·xH2O non cristallin peut être un ACP, surtout au cours des phases précoces de formation. A des pH physiologiques, l'ACP se transforme en petits cristaux applatis contenant de fortes quantités de phosphate acide facilement remplaçable. Le fait de laver la couche de surface produit un changement chimique dans les nouveaux cristaux: des cristaux non lavés donnent des diagrammes de diffraction d'apatite peu cristallins, ainsi que des spectres infra-rouges peu nets, intermédiaires entre des apatites et du phosphate octocalcique. Des explications structurales sont proposées et les compositions minérales amorphe/cristalline de l'os et du cartilage sont recalculées.
    Abstract: Zusammenfassung Ungewaschene Proben von amorphem Calciumphosphat (ACP) enthalten eine unersetzliche labile Fraktion, welche reich an saurem Phosphat ist und ein niederes Ca/P-Verhältnis hat und welche während des Waschprozesses unwiderruflich verloren geht. Natives ACP, welches im pH-Bereich 6,6–10,6 ausgefällt wurde, variierte im molaren Ca/P-Verhältnis zwischen 1,18 und 1,50 und in HPO 4 2− /totales P zwischen 33,0 und 10,1%. Bei pH 7,40 hatte natives ACP ein molares Ca/P-Verhältnis von 1,36±0,02 und enthielt 22,8 (±2,2)% HPO 4 2− . Die Werte beim ungewaschenen Niederschlag rühren weder von aus dem Überstand aufgenommenem Ca2+ und HPO2−, noch von außen kommendem Na+, Cl− und CO 3 2− her. Die amorphen Calciumphosphate werden als eine Klasse von Salzen erkannt, welche veränderliche chemische, aber identische glasartige physicochemische Eigenschaften haben. Nicht kristallines CaHPO4·xH2O kann auch ein ACP sein, besonders in den frühen Bildungsstadien. Bei physiologischem pH verwandelt sich ACP in kleine plattenförmige Kristalle, welche große Mengen von leicht ersetzbarem saurem Phosphat enthalten. Das Waschen dieser Oberflächenschicht erzeugte chemische Veränderungen in den resultierenden Kristallen; ungewaschene Kristalle zeigten ein Diffraktionsmuster, das nur schwach demjenigen des kristallinen Aspatites glich, aber ein schlecht aufgelöstes Infrarotspektrum, welches zwischen Apatit und Octocalciumphosphat war. Es werden strukturelle Erklärungen für alle diese Phenomena diskutiert, und revidierte amorph/kristalline Mineralzusammensetzungen von Knochen und Knorpel wurden neu berechnet.
    Notes: Abstract Unwashed samples of amorphous calcium phosphate (ACP) contain an irreplaceable labile fraction, rich in acid phosphate and low in Ca/P ratio, which is irreversibly lost during the washing process. Native ACP precipitated in the pH range 6.6–10.6 varied in Ca/P molar ratio from 1.18 to 1.50 and in HPO 4 2− /total P from 33.0% to 10.1%. At pH 7.40, native ACP had a Ca/P molar ratio of 1.36±0.02 and contained 22.8 (±2.2)% HPO 4 2− . Unwashed precipitate data could not be attributed to either trapped supernatant Ca2+ and HPO 4 2− or extraneous Na+, Cl−, and CO 3 2− . The amorphous calcium phosphates are recognized as a class of salts having variable chemical but identical glass-like, physicochemical properties. Non-crystalline CaHPO4·xH2O may also be an ACP, especially during early formative stages. At physiological pH, ACP transforms to small platy crystals containing large amounts of readily-replaceable acid phosphate. Washing this surface layer produced chemical alterations in the resultant crystals; unwashed crystals had poorly-crystalline apatitic diffraction patterns but exhibited poorly-resolved infrared spectra intermediate between apatite and octacalcium phosphate. Structural explanations for all these phenomena are discussed, and revised bone and cartilage amorphous/crystalline mineral compositions have been re-calculated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 23 (1977), S. 13-17 
    ISSN: 1432-0827
    Keywords: Dental calculus ; Glycopeptide ; Chemistry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary A method is described for the isolation and purification of a sulphated glycopeptide from human supragingival calculus. The compound was isolated after using EDTA treatment, 2 M CaCl2 extraction, proteolytic digestion, ethanol precipitation, and finally purified by DEAE cellulose chromatography. It migrated as a single component on cellulose acetate electrophoresis, and chemical and infrared spectral analysis showed the presence of covalently attached sulphate groups. The sulphated glycopeptide was distinguished from being a sulphated glycosaminoglycan.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1432-0827
    Keywords: Bacterial amphophile ; Purification ; Chemistry ; Resorption ; Ca influx ; Cyclic AMP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The bone resorptive factor and amphipathic antigen (AcA) previously identified by us in preparations fromActinomyces viscosus have been partially purified, characterized chemically, and compared. They elute at the same location on chromatography with Ac 22. The fatty acid composition of AcA and the bone resorptive factor is the same. Some differences in carbohydrate composition are observed. TheActinomyces factor does not affect calcium influx or cyclic AMP in isolated bone cells. Therefore it is concluded that AcA stimulates resorption either by gaining entrance into bone cells or by way of a yet undetermined second messenger.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 8 (1971), S. 228-236 
    ISSN: 1432-0827
    Keywords: Skin ; Calcinosis ; Keratin ; Chemistry ; X-ray diffraction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Des études histologiques antérieures ont montré que le follicle pileux est particulièrement susceptible de se calcifier, lorsque la peau de rats hypercalcémiques est lésée. Des analyses chimiques et par diffraction aux rayons X du follicule ont confirmé ce résultat. — En se basant sur l'augmentation du calcium et du phosphore, les calcifications débutent dans le tissue folliculaire 6–12 h après une blessure d'intensité moyenne de la peau de rats, ayant reçu du dihydrotachysterol (DHT), et 24–48 h après une blessure similaire chez des rats non injectés. Les diagrammes de diffraction aux rayons X sont diffus. Trois heures après la blessure, on note une augmentation du calcium du tissu folliculaire qui ne semble pas en rapport avec le DHT qui traduit probablement une liaison de calcium plutôt qu'un dépot minéral.
    Abstract: Zusammenfassung Frühere histologische Untersuchungen haben gezeigt, daß der Haarfollikel besonders anfällig für Verkalkungen ist, wenn die Haut von hypercalcämischen Ratten verletzt wird. Dieses Resultat wurde nun durch direkte chemische Bestimmungen und Röntgendiffraktions-analysen von Follikelgewebe bestätigt. Aufgrund der erhöhten Calcium- und Phosphatwerte kann gesagt werden, daß nach einer leichten Quetschung der Haut von Ratten, die mit Dihydrotachysterol (DHT) behandelt wurden, im Haarfollikelgewebe nach 6–12 Std Mineral-ablagerungen stattfanden, wogegen Kontrollratten mit der gleichen leichten Hautverletzung diese Ablagerungen erst nach 24–48 Std zeigten. Röntgendiffraktionsanalysen ergaben ein diffuses Apatit-Muster. Innerhalb 3 Std nach der Verletzung wurde ein Anstieg des Calcium-gehaltes im Follikelgewebe beobachtet, der nicht im Zusammenhang mit der DHT-Behandlung stand, also nicht eine Mineralablagerung, sondern eher eine Bindung von Calcium widerspiegelte.
    Notes: Abstract Previous histological investigations have shown that the hair follicle is particularly susceptible to mineralization when the skin of hypercalcaemic rats is injured. Direct chemical and X-ray diffraction analyses of follicle tissue have now confirmed this finding. As judged by increases in both calcium and phosphorus, mineral deposits began to form in hair follicle tissue 6–12 h after a mild crush injury to the skin of rats dosed with dihydrotachysterol (DHT), and 24–48 h after a similar injury to the skin of non-dosed rats. X-ray diffraction gave a diffuse apatite pattern. Within 3 h of injury there was a rise in the calcium content of follicle tissue which was not related to DHT-dosing and which was probably a reflection of calcium binding rather than mineral deposition.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 8 (1971), S. 304-319 
    ISSN: 1432-0827
    Keywords: Chemistry ; Calcium ; Phosphate ; Solubility ; Computer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé Un programme d'ordinateur a été mis au point pour calculer les activités ioniques du calcium et l'orthophosphate dans un grand nombre de solutions. Dans le cas de solutions synthétiques, les calculs sont vérifiés en comparant les valeurs de pH, obtenues par ordinateur, avec celles observées expérimentalement. Des essais de ce type, avec des solutions possèdant des concentrations de calcium et d'orthophosphate trouvées dans les liquides biologiques et à des valeurs de pH variant de 3.00 à 10.00, indiquent que le programme est adapté pour des applications biologiques. Le programme n'est pas effectif pour des solutions, dans les lesquelles l'ion bromure est la source principale de la force ionique, sans doute, par manque d'équation étendue de Debye-Hückel dans ces circonstances. Aucune formation de complexe de phosphate de sodium n'a été notée à des concentrations biologiques normales.
    Abstract: Zusammenfassung Es wurde ein Computer-Programm ausgearbeitet, um die Ionenaktivitäten von Calcium und Orthophosphat in einer breiten Varietät von Lösungen zu berechnen. Die Berechnungen wurden bei synthetischen Lösungen durch Vergleiche zwischen den auf diese Weise errechneten pH-Werten und den experimentell gefundenen kontrolliert. Diese Art Kontrollen mit Calcium-und Orthophosphatkonzentrationen, wie sie in biologischen Flüssigkeiten gefunden werden, und mit pH-Werten zwischen 3,0 und 10,0 wies darauf hin, daß das Programm für biologische Anwendungen geeignet war. Das Programm konnte nicht benützt werden für solche Lösungen, bei welchen hauptsächlich das Bromidion zur Einstellung der Ionenstärke verwendet wurde, vermutlich weil die erweiterte Debye-Hückel-Gleichung unter diesen Umständen nicht anwendbar ist. Die Bildung eines Natriumphosphat-Komplexes unter normalen biologischen Konzentrationen konnte nicht nachgewiesen werden.
    Notes: Abstract A computer program has been designed to calculate the ionic activities of calcium and orthophosphate in a wide variety of solutions. In the case of synthetic solutions the calculations were checked by comparing the computed pH values with those observed experimentally. Tests of this type with solutions having the concentrations of calcium and orthophosphate found in biological fluids and with pH values ranging from pH 3.0–10.0 indicated that the program was suitable for biological applications. The program was not effective for solutions in which the bromide ion was a principal source of ionic strength probably because of the failure of the extended Debye-Hückel equation under those circumstances. No evidence for the formation of any sodium phosphate complex at normal biological concentrations could be found.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 1432-0975
    Keywords: Key words Otolith ; Chemistry ; ICP-MS ; Stock discrimination ; Epinephelus striatus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Geosciences
    Notes: Abstract  We examined the utility of otolith minor and trace element chemistry, assayed with inductively coupled plasma mass spectrometry (ICP-MS), as a means of delineating population structure in the Nassau grouper (Epinephelus striatus). We characterized the elemental composition of otoliths collected in 1993 from three locations in Exuma Sound, Bahamas and from Glover Reef, Belize in 1995. A single location in Exuma Sound was sampled in 1994 to test temporal variability in otolith composition. Five elements (Ca, Zn, Sr, Ba and Pb) were routinely detected, at levels significantly above background, by solution-based ICP-MS. Results from analysis of variance of elemental data, expressed as a ratio to Ca, indicated that there were no significant differences among the Exuma locations for any element, but significant variability was found between Glover Reef and the pooled Exuma localities for Zn/Ca, Sr/Ca and Ba/Ca ratios. Significant inter-annual differences at one Exuma Sound location was restricted to Ba/Ca ratios. Discriminant function analysis correctly classified 86% and 95% of the Belize and pooled Exuma sites, respectively. Otoliths from Belize were characterized by low Zn/Ca and high Ba/Ca and Pb/Ca ratios compared to otoliths from fish collected in Exuma Sound. Although differences in Ba levels may be related to upwelling at Glover Reef, more data are needed to definitely link otolith composition with regional differences in water chemistry.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Accreditation and quality assurance 5 (2000), S. 409-413 
    ISSN: 1432-0517
    Keywords: Key words Metrology ; Comparisons ; Chemistry ; Standards
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract  After stressing the importance in the modern world of accurate and reproducible measurements, the actions taken by the Bureau International des Poids et Mesures to set up, together with the regional metrology organizations, a series of key comparisons are described. They are the technical foundation of a mutual recognition of national measurement standards arrangement prepared in conjunction with the National Metrology Institutes (NMIs). This arrangement also includes the recognition of calibration and measurement certificates issued by these institutes. Then, the consequences of this arrangement for trade are described. The case of chemical analysis is illustrated by the application of the Kyoto protocol on the reduction of greenhouse gases. But the global workload to be taken up by the International Committee of Weights and Measures, its Consultative Committee for Amount of Substance and the NMIs is huge.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Aquatic sciences 51 (1989), S. 108-128 
    ISSN: 1420-9055
    Keywords: Chemistry ; mountain lakes ; silica ; acidity ; sediment
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Alpine lakes in siliceous catchments of Tyrol and Carinthia (Austria) show signs of acidification. About 9% of the studied lakes have no alkalinity, more than 20% are below pH 6. About two thirds of all lakes have acid neutralizing capacities below 100 μeq 1−1. In spite of moderate precipitation acidity, some lakes show considerable concentrations of dissolved reactive aluminum during or shortly after snowmelt. High altitude lakes of the Alps are definitely more acidic than high mountain lakes in remote areas. Large differences in water and soil chemistry of nearby situated lakes were attributed to heterogeneities of bedrock geology. Paleolimnological investigations on former pH values of five lakes, based on diatom assemblages in the sediment, showed different developments: recent and past acidification, stable conditions, and alkalinization.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 224 (1995), S. 81-84 
    ISSN: 1572-946X
    Keywords: Chemistry ; Depletions ; Shocks ; IRAS 05338-0624 ; NGC 1333 IRAS 4
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract High resolution interferometer and single-dish observations of young, deeply embedded stellar systems reveal a complex chemistry in the circumstellar environments of low to intermediate mass stars. Depletions of gas-phase molecules, grain mantle evaporation, and shock interactions actively drive chemical processes in different regions around young stars. We present results for two systems, IRAS 05338-0624 and NGC 1333 IRAS 4, to illustrate the behavior found and to examine the physical processes at work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 216 (1994), S. 153-154 
    ISSN: 1572-946X
    Keywords: Chemistry ; Molecular Hydrogen ; Cloud Models
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Observations of the CO J=1-0 line are commonly used as a tracer for molecular material in clouds. The ratio of the H2 column density to the integrated intensity of this line,X, is often taken to be constant, despite theoretical and observational uncertainty. We have tried to identify how this ratio depends on cloud parameters, testing a simple theoretical argument suggesting its invariance with respect to density. The apparent constancy can be understood if clouds are clumpy on scales of Av ≈ 1-2 mag.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 233 (1995), S. 125-137 
    ISSN: 1572-946X
    Keywords: Interstellar Medium ; Dark Clouds ; Chemistry ; Bistability ; C-shock Waves
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Shock waves perturb the chemical state of the interstellar gas. We consider the effects of C-shocks on the composition of molecular clouds, for a range of values of the pre-shock gas density and magnetic induction. The time required to re-establish equilibrium in the post-shock gas depends on the initial conditions and can become very large. The significance of the two known chemical phases of dark clouds and of bistability is considered in this context.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Astrophysics and space science 233 (1995), S. 161-164 
    ISSN: 1572-946X
    Keywords: Stars ; Chemistry ; Diffusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We have assessed the role of diffusion in determining chemical abundances in molecular interface regions. Chemical models have been developed which include the appropriate diffusion terms and that are appropriate to a narrow diffusion region (∼0.01pc) that may exist at the interface between a dark core and a hot, shocked T-Tauri wind. We have assumed pressure balance throughout and have calculated the chemical abundances as functions of time and position through the interface. The results show that significant enhancements of detectable molecules/transitions are expected (e.g. CO J=6→5, OH and CH). Using a realistic value of the diffusion coefficient a diffusive region of dimension 0.01pc may be established within about 104 years. In general it seems likely that diffusion processes are highly significant on these and smaller lengthscales.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Boundary layer meteorology 85 (1997), S. 197-222 
    ISSN: 1573-1472
    Keywords: Turbulence ; Chemistry ; Closure ; Convective boundary layer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract We study the interactions of chemistry and turbulent mixing of tracersin the convective boundary layer with a second-order closure model,including higher order chemistry terms. In order to limit the number of predictive equations we prescribe the profiles for ¯w¯Θ, ¯w¯θ ¯θ and the lengthscale l. However, for model validation we treat temperature and humidity asinert tracers, and compare the results with profiles observed during theAir Mass Transformation Experiment, and with similarity expressions for thesurface layer. We find good agreement of the mean profiles, but the (co-)variances are slightly underpredicted. Furthermore, the model usesdiagnostic equations expressing third moments of concentration in terms ofsecond moments and their vertical derivatives. They are compared withlarge-eddy model results, showing good agreement and, therefore, thesimplifications are justified. The model is applied to the transport of two gases subject to one bimolecular reaction. The importance of concentration correlations on themean transformation rate is studied. For two gases diffusing in oppositedirections we find for moderate and fast chemistry a 50% and90% decreased transformation rate due to the negatively correlatedconcentrations. These values are similar to large-eddy results of Schumannand Sykes et al. For two bottom-up tracers we find that the covariance ofboth reactive species is either positive or negative, increasing or reducingthe effective transformation rate depending on the Damköhler number (the ratio of the turbulent and the chemistry timescale). A significantdirect influence of chemistry on the flux divergence is found in bothcases. According to the model the effective transport to mid-levels of theboundary layer is increased when two reactive tracers diffuse in oppositedirections, and decreased in the case of two bottom-up tracers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Earth, moon and planets 88 (2000), S. 35-58 
    ISSN: 1573-0794
    Keywords: Chemistry ; interplanetary dust particles (IDPs) ; Leonids ; meteor trails ; meteoroids ; meteors ; structure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract The cometary Leonid meteoroids represent a size range in between largest carbon-richIDPs and the smallest CI meteorites. Their dustball structure and chemistry offer anopportunity to constrain hierarchical dust accretion inferred from petrologic studies ofaggregate and cluster IDPs. The Leonid shower meteoroids of known ``comet ejection''ages provide an opportunity to study space weathering of cometary dust over periodsof up to several hundred years. The meteors and aggregate and cluster IDPs displaycontinuous thermal modification of organics and volatile element (Na, K-bearing phases), that occur as discrete minerals and amorphous solids each different response during kinetically controlled ablation. Leonid meteoroids are not excessively Na-rich. The occurrences of Leonid meteors can now be accurate predicted and combined withknowledge better models for the settling rates, collections of surviving dust becomea comet nucleus-sampling mission.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Journal of science education and technology 5 (1996), S. 193-201 
    ISSN: 1573-1839
    Keywords: Chemistry ; chemistry education ; multiple intelligences ; imagery ; visual-spatial thinking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Natural Sciences in General , Technology
    Notes: Abstract Chemistry has evolved from a science dominated by mathematics into a science highly dependent on spatial-visual intelligence. Yet the chemical content of introductory courses remains taught essentially the same as 40–50 years ago. Chemistry, today, is recognized by chemists as the molecular science. Yet, school chemistry is alienated from that perception. Thanks to the computer, young people are more comfortable with visual imaging than their instructors were at the same age. Thus the time is rife to reinvigorate chemistry education by means of the visual-spatial approach, an approach wholly in conformance with the way modern chemistry is thought about and practiced.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 8 (1986), S. 245-251 
    ISSN: 1573-739X
    Keywords: Analysis ; Antineoplastic agents ; Biosynthesis ; Botany ; Chemistry ; Cytotoxins ; Eupatorium cannabium ; Sesquiterpenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A review onEupatorium cannabinum L. is given, including botany, history and constituents. The sesquiterpene lactones are discussed in more detail, covering their biosynthesis, isolation, analysis and biological activity. Special attention is paid to the cytotoxic and antitumour activities of the sesquiterpene lactones.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 9 (1987), S. 305-314 
    ISSN: 1573-739X
    Keywords: Atrial natriuretic factor ; Blood pressure ; Chemistry ; Diuresis ; Homeostasis ; Kidney ; Muscle, smooth ; Natriuresis ; Receptors, endogenous compounds ; Renin-angiotensin system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract It is now known that cardiac atria play an important role in blood pressure and volume regulation. Mechanical distension of the atria results in the release of a potent diuretic and natriuretic agent or agents termed the atrial natriuretic factor (ANF). Several structurally related forms of ANF exist in man and it is thought that these represent precursory forms of a single optimally active molecule and/or the presence of more than one form of active ANF. The chemical structure of ANF between different mammalian species is similar. ANF receptors have been identified in kidney, brain, vascular endothelial and smooth muscle cells, tracheal and bronchial smooth muscle and the adrenal glands of many mammalian species, including man. This would suggest that ANF influences blood pressure and volume homoeostasis by affecting any one of a number of biochemical or physiological mechanisms via different target tissues. ANF is now considered a potentially valuable therapeutic agent for the treatment of hypertension and congestive heart failure. Synthesis of potent receptor antagonists could be extremely useful in the treatment of various clinical situations which are produced or complicated by endogenously produced ANF, such as chronic orthostatic hypotension.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 10 (1988), S. 93-95 
    ISSN: 1573-739X
    Keywords: Anthracyclines ; Chemistry ; Drug stability ; Mitomycins
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 10 (1988), S. 101-116 
    ISSN: 1573-739X
    Keywords: Chemistry ; Chromatography ; Etoposide ; Immunoassay ; Metabolism ; Podophyllotoxin ; Pharmacokinetics ; Teniposide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Etoposide (VP 16-213) and teniposide (VM 26) are semisynthetic epipodophyllotoxin derivatives active against a variety of tumours. The clinical efficacy has led to an increasing interest in these compounds. This review presents information on the mechanism of action, biochemical pharmacology, bioanalysis, metabolism and pharmacokinetics of etoposide and teniposide.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Pharmacy world & science 13 (1991), S. 109-118 
    ISSN: 1573-739X
    Keywords: Chemistry ; Consumer product safety ; Drug packaging ; Environmental pollution ; Plasticizers ; Polyvinyls
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract In this report the state of the art with respect to PVC as pharmaceutical packaging material is described. A general introduction into the applications of PVC is followed by a description of its production process. The metabolic effects of the monomer of PVC, vinyl chloride and of the most commonly used plasticizer diethylhexylphthalate are mentioned. Special attention is given to the pharmaceutical properties of plasticized PVC bags in comparison to other plastics and the environmental aspects of waste PVC disposal. Although there are emotional and political queries regarding the future use of PVC as a (pharmaceutical) packaging material, we conclude that there is no scientific justification for a total or partial ban of PVC. PVC will remain a fact of life as a cheap, versatile, high-performance and well-investigated plastic material for medical and pharmaceutical applications, to be replaced by newer plastics only for certain well-defined indications where the requirements of the plastic to be used are so specific that it will economically and technically be justified to use another polymer. Community and hospital pharmacists have to be prepared for a role in intake of waste plastic disposables, probably against deposit money, in order to fulfil the logistics needed for recycling.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    ISSN: 1573-739X
    Keywords: Antimalarials ; Artemisia annua L ; Artemisinin ; Biosynthesis ; Chemistry ; Clinical trials ; Pharmacology ; Phytochemistry ; Sesquiterpenes ; Toxicology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Artemisinin, a sesquiterpene lactone endoperoxide isolated fromArtemisia annua L., and a number of its semisynthetic derivatives have shown to possess antimalarial properties. They are all eflective againstPlasmodium parasites that are resistant to the newest and commonly used antimalarial drugs. This article gives a survey of the literature dealing with artemisinin-relaled antimalarial issues that have appeared from the end of 1989 up to the beginning of 1994. A broad range of medical and pharmaceutical disciplines is covered, including phytochemical aspects like the selection of high-producing plants, analytical procedures, and plant biotechnology. Furthermore, the organic synthesis of artemisinin derivatives is discussed, as well as their mechanism of action and antimalarial activity, metabolism and pharmacokinetics, clinical studies, sideeffects and toxicology, and biological activities other than antimalarial activity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 545-545 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    ISSN: 0886-9383
    Keywords: Derivatization reaction ; Factorial design ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A number of nucleophiles have been successfully identified and quantified using the Kröhnke reaction with 2,3-diphenyl derivatives of quinolizinium salts. Optimization of the reaction conditions by means of a mathematical model involving analysis of the response surface has led to a better understanding of the factors exerting an influence on the above reaction.The parameters chosen were temperature, reaction time, base concentration, water concentration and nucleophile concentration. The reaction was developed in polar aprotic solvents (acetone, acetonitrile). To facilitate the nucleophilic attack, the presence of an organic base (triethylamine) was necessary, although concentrations in excess of 0·15M did not alter the development of the reaction. Since pharmaceutical solutions are often aqueous, the influence of water on the reaction was studied. Low water volumes have no significant influence on the opening of the quinolizinium ring by the nucleophilic reagent. However, when the water proportion exceeded that of the organic solvent, the fluorescence intensity was lower than expected. Development of the fluorescent reaction product was first detected 5 min after the reaction started. The fluorescence intensity reached its optimum value after 138 min.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 65-83 
    ISSN: 0886-9383
    Keywords: Trilinear decomposition ; Receptor modeling ; Source identification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In many cases, monitoring data for ambient airborne particles can be organized in the form of a three-way data table with one way for chemical species, one for sampling periods and one for sites. A direct trilinear decomposition followed by a matrix reconstruction (DTDMR) is developed to analyze such a data table as a whole. The three-way data set is composed into three two-way matrices by a direct trilinear decomposition (DTD). The column vectors of each of the matrices are called ‘source profiles’, ‘emission patterns’ and ‘site coefficients’ respectively. Particulate sources are identified by examining both their source profiles and emission patterns. After the sources have been identified, emission patterns and site coefficients are used to produce a three-way matrix that gives estimates of mass contributions of sources to the samples collected at every site in every period. By simulation study, not only has the method been verified, but a good indicator has been found that shows the number of factors (i.e. sources) in the system. Unlike other receptor models, DTDMR does not require source profile data and does not involve trial-and-error procedures. Since DTDMR identifies sources based on variations in two dimensions, it has a higher potential to distinguish two sources that have similar chemical compositions. The DTDMR model has provided excellent results with simulated data and has been applied in a real world three-way data set.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 163-175 
    ISSN: 0886-9383
    Keywords: Multiple-correspondence analysis ; Starch granule description ; Image analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Raw starch is composed botanically of characteristic granules of various sizes and shapes, so that each kind of starch may be characterized by the population of its granules. In the present study ten commercial starch species were studied: wheat, rice, manioc, potato, arrowroot, amylomaize, normal maize, waxy maize and two different banana species. Six variables measuring the size and shape of granules were obtained by image analysis. The objective was to find a method to describe and compare the granule populations of the ten species. For such a study, multiple-correspondence analysis (MCA) was applied. MCA makes it possible to draw similarity maps of categories and objects. For each starch species the frequency distributions (histograms) of the six variables were assessed and each granule was characterized by its species and the classes of histograms to which it belonged. MCA was applied to the granule table and a description of the histogram classes and the granules was obtained. From the variables description a general typology of the granules was deduced. The similarity maps showed considerable scatter of the granules for all species except rice. A particular species could therefore not be identified by a single granule, but the granule distribution seemed to be characteristic. MCA was an appropriate method to analyse these data because it points out non-linear relationships between quantitative and qualitative variables.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 177-188 
    ISSN: 0886-9383
    Keywords: PLS ; Prediction error ; Background constituents ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A modification of a technique proposed by Lorber and Kowalski for the estimation of prediction errors is presented. The method is applied to five data sets. The results show that for some data sets the estimated prediction errors are close to the actual prediction errors for samples within the calibration range, while samples outside the calibration range must be background corrected before quantification of the prediction error.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 6 (1992), S. 199-216 
    ISSN: 0886-9383
    Keywords: MARS ; Splines ; Multivariate calibration ; Non-linear ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This tutorial paper presents a simplified view of one of the more recently published multivariate calibration methods particularly suited to dealing with non-linear data sets. The method is referred to as MARS and stands for multivariate adaptive regression splines. Simple examples are provided to explain the workings of the method.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 47-50 
    ISSN: 0886-9383
    Keywords: Classification ; Pattern recognition ; Preprocessing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Over the past 15 years the linear learning machine has been applied to a large number of chemical problems. The learning machine approach is conceptually simple and does not require knowledge about the statistical distribution of the data. However, there are problems associated with this approach. One problem which has not been investigated is the influence of mislabeled samples on the positioning of the hyperplane in feature space. If a few samples in a data set are incorrectly tagged prior to training (i.e. the samples are labeled as members of class 2 even though they are actually members of class 1), it is still possible using the linear learning machine to achieve a classification success rate of 100% for the training set. However, unfavorable results will be obtained for the prediction set. The magnitude of this effect and its potential implications regarding the proper use of the linear learning machine are discussed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 51-59 
    ISSN: 0886-9383
    Keywords: Deconvolution ; Jansson's method ; Peak restoration ; Iterative deconvolution ; Peak resolution ; Non-linear deconvolution ; Super-resolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In previous papers Jansson's method was found to be successful at deconvolving severely overlapped gas chromatographic peaks. In the most recent paper the method was evaluated with respect to quantitative accuracy, peak area and retention time repeatability. The problems associated with deconvolving noisy data and some alternatives which can improve the ability of Jansson's method to deconvolve noisy data are discussed. These alternatives include presmoothing the data with a nine-point, third-order polynomial filter and data reblurring. This paper will test these methods on peaks with various degrees of resolution and signal-to-noise ratios.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 61-77 
    ISSN: 0886-9383
    Keywords: Infrared ; Spectroscopy ; Spectrometry ; Retrieval ; Confirmation ; Chemometrics ; Adequate peaks ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the series of analytical techniques for identification of chemical substances, infrared spectrometry presents by far the highest information content. However, the information is most complicated too. It concerns a multitude of band positions, band intensities and band shapes, which, moreover, can be disturbed by matrix and other effects. The high redundancy, however, allows conclusions to be made by a qualitative, subjective procedure.IR is often used to prove the equality between a sample and a reference material, e.g. in quality control of a production process. In forensic control, the question to be answered is mostly not to prove equality, but whether or not the presence of a compound in a sample, e.g. a drug, can be proved. Moreover, testing has to be performed according to objective rules.To fulfil these requirements, a new retrieval algorithm, the ‘Adequate Peaks Search’, is presented. It concerns representing the reference spectra by sets of adequate peak positions and the sample spectrum by a set of all peak positions, whereafter the cross-sections of the sample set and the reference sets are determined. The concept ‘adequate peak’ is defined and criteria have been formulated to evaluate the results into a positive (presence of the analyte is proved) or negative (presence is not proved) conclusion.The detection limit when the Adequate Peaks Search (APS) method was applied was four to seven times lower than that attained by a number of experts.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 79-90 
    ISSN: 0886-9383
    Keywords: PLS ; Three-way matrices ; Calibration ; Residual bilinearization ; Background correction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: When using hyphenated methods in analytical chemistry, the data obtained for each sample are given as a matrix. When a regression equation is set up between an unknown sample (a matrix) and a calibration set (a stack of matrices), the residual is a matrix R.The regression equation is usually solved by minimizing the sum of squares of R. If the sample contains some constituent not calibrated for, this approach is not valid. In this paper an algorithm is presented which partitions R into one matrix of low rank corresponding to the unknown constituents, and one random noise matrix to which the least squares restrictions are applied. Properties and possible applications of the algorithm are also discussed.In Part 2 of this work an example from HPLC with diode array detection is presented and the results are compared with generalized rank annihilation factor analysis (GRAFA).
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 91-96 
    ISSN: 0886-9383
    Keywords: Sample size ; Monte Carlo ; Multivariate, normal ; Q-Q plots ; Classification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Because many pattern recognition techniques are predicated on the assumption of mutivariate normal data, Monte Carlo simulation studies were performed to determine the number of samples that are necessary to describe a multivariate normal population adequately. From these studies we have learned that hundreds of samples are required. These results suggest that parametric procedures should only be used to analyze very large data sets.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 97-100 
    ISSN: 0886-9383
    Keywords: Matrix decomposition ; NIPALS ; Principal component ; SIMCA ; PLS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The Non-linear Iterative Partial Least Squares (NIPALS) algorithm is used in principal component analysis to decompose a data matrix into score vectors and eigenvectors (loading vectors) plus a residual matrix. NIPALS starts with some guessed starting vector. The principal components obtained by NIPALS depends on the starting vector; the first principal component could not always be computed. Wold has suggested a starting vector for NIPALS, but we have found that even if this starting vector is used, the first principal component cannot be obtained in all cases. The reason why such a situation occurs is explained by the power method. A simple modification of the original NIPALS procedure to avoid getting smaller eigenvalues is presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 101-101 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 102-102 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 102-102 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 103-121 
    ISSN: 0886-9383
    Keywords: Kalman filter ; Recursive digital filter ; Square-root filter ; Information filter ; Parameter estimation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The use of recursive filtering techniques for parameter estimation in a variety of areas is reviewed. In particular, the Kalman filter algorithm is described, along with several variations, including square-root, UDUT and information filters. The solution to parameter estimation problems is discussed for both linear and non-linear models. Applications described include calibration, curve resolution in spectroscopy, chromatography, electrochemistry, kinetic analysis and process monitoring.
    Additional Material: 5 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 243-253 
    ISSN: 0886-9383
    Keywords: Orthogonal expansion ; Mapping ; Modelling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this paper we discuss the orthogonal expansion of data matrices and its application to mapping and modelling. Two new methods, modified optimal discriminant plane (MODP) for mapping and order Gram-Schmidt orthogonalization (OGSO) for modelling, are proposed and examples are given.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 381-392 
    ISSN: 0886-9383
    Keywords: Factor analysis ; Kolmogorov-Smirnov test ; Non-parametric tests in factor analysis ; Non-parametric test for principal components ; Principal component analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Each eigenvector of the dispersion matrix [X]T [X] was shown to be a partial predictor of the original data matrix [X], the sum of the predictions from the individual principal components being equal to the expectance of [X]. By comparing the distributions of the members of two neighbouring predicted matrices, [X̃]1…i and [X̃]1…i+1 (i.e. the sums of the first i and i + 1 individual predictions respectively), it was shown that they should be indistinguishable provided that i is equal to or greater than the effective rank of [X], and significantly different otherwise. This was confirmed by analysing the visible absorption spectra of methyl orange and methyl red solutions as well as the Raman spectra of Na2SO4 and MgSO4 solutions. On the grounds of these findings, a non-parametric goodness-of-fit test for assessing the effective rank of [X] was proposed which proved to be comparatively conservative and more robust than most currently used tests.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 447-452 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 477-494 
    ISSN: 0886-9383
    Keywords: Three-way principal components analysis ; Core matrix ; Body diagonalization ; Lower and upper bounds ; Simulation ; Soil contamination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In contrast with conventional PCA, a direct superposition and joint interpretation of loading plots is not possible in three-way PCA, since there may be data variance which is described by unequal components of different modes. The contributions to variance of all possible combinations of components are described in the core matrix. Body diagonalization, which is achieved by appropriate rotation of component matrices, is an essential tool for simplifying the core matrix structure. The maximum degree of body diagonality which may be obtained from such transformations is analysed from both the mathematical and simulation viewpoints. It is shown that, at least in the average case, high degrees can be expected, which makes the procedure reasonable for many practical applications. Furthermore, simulation as well as theoretical derivation show that the success of body diagonality depends on the so-called polarity of the core array. The methodology is illustrated by a three-way data example from environmental chemistry.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 495-526 
    ISSN: 0886-9383
    Keywords: Standard errors ; Eigenvalues ; PCA ; MLR ; GRAM ; Rank estimation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New expressions are derived for the standard errors in the eigenvalues of a cross-product matrix by the method of error propagation. Cross-product matrices frequently arise in multivariate data analysis, especially in principal component analysis (PCA). The derived standard errors account for the variability in the data as a result of measurement noise and are therefore essentially different from the standard errors developed in multivariate statistics. Those standard errors were derived in order to account for the finite number of observations on a fixed number of variables, the so-called sampling error. They can be used for making inferences about the population eigenvalues. Making inferences about the population eigenvalues is often not the purposes of PCA in physical sciences. This is particularly true if the measurements are performed on an analytical instrument that produces two-dimensional arrays for one chemical sample: the rows and columns of such a data matrix cannot be identified with observations on variables at all. However, PCA can still be used as a general data reduction technique, but now the effect of measurement noise on the standard errors in the eigenvalues has to be considered. The consequences for significance testing of the eigenvalues as well as the usefulness for error estimates for scores and loadings of PCA, multiple linear regression (MLR) and the generalized rank annihilation method (GRAM) are discussed. The adequacy of the derived expressions is tested by Monte Carlo simulations.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 7 (1993), S. 559-566 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 21-36 
    ISSN: 0886-9383
    Keywords: GRAM ; Tucker ; Unfold ; NBRA ; Second-order ; Three-way ; PARAFAC ; Trilinear ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: If an analytical instrument or instrumental method gives a response matrix when analyzing a pure analyte, the instrument or instrumental method is called a second-order method. Second-order methods that generate a response matrix for a pure analyte of rank one are called rank-one second-order methods. If the response matrix of a pure analyte is not rank one, essentially two cases exist: medium rank (between two and five) and high rank (greater than five). Subsequently, medium- and high-rank second-order calibration tries to use medium- and high-rank second-order methods to analyze for analytes of interest in a mixture. A particular advantage of second-order methods is the ability to analyze for analytes of interest in a mixture which contains unknown interferences. Keeping this advantage is the challenge on moving away from rank-one second-order calibration methods. In this paper a medium-rank second-order calibration method is proposed based on least-squares restricted Tucker models. With this method the second-order advantage is retained.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 81-93 
    ISSN: 0886-9383
    Keywords: Sensory evaluation ; Cumulative ranks ; Assessor variation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A graphical method of assessing differences between sets of rankings based on cumulative ranks is developed. The method can be used to identify rankings that differ over all or just part of the range of objects ranked. The method is applied to an example of sensory evaluation of green peas in which ten assessors scored six attributes on each of 60 samples.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 155-168 
    ISSN: 0886-9383
    Keywords: Trilinear models ; Tensorial resolution ; PARAFAC ; Swamps ; Two-factor degeneracy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The alternating least squares PARAFAC algorithm is a useful tool for resolving trilinear three-way data arrays. Occasionally, however, it becomes bogged down for many iterations in the vicinity of a poor quality resolution before moving on to a much superior optimum fit. We investigate this behavior in a simulation study and suggest ways of overcoming the obstacles it presents.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 181-203 
    ISSN: 0886-9383
    Keywords: RAFA ; GRAM ; Eigenvalues ; Bias ; Variance ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rank annihilation factor analysis (RAFA) is a method for multicomponent calibration using two data matrices simultaneously, one for the unknown and one for the calibration sample. In its most general form, the generalized rank annihilation method (GRAM), an eigenvalue problem has to be solved. In this second paper expressions are derived for predicting the bias and variance in the eigenvalues of GRAM. These expressions are built on the analogies between a reformulation of the eigenvalue problem and the prediction equations of univariate and multivariate calibration. The error analysis will also be performed for Lorber's formulation of RAFA. It will be demonstrated that, depending on the size of the eigenvalue, large differences in performance must be expected. A bias correction technique is proposed that effectively eliminates the bias if the error in the bias estimate is not too large. The derived expressions are evaluated by Monte Carlo simulations. It is shown that the predictions are satisfactory up to the limit of detection. The results are not sensitive to an incorrect choice of the dimension of the factor space.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 337-354 
    ISSN: 0886-9383
    Keywords: Chemometrics ; Chemometrics Society ; History of chemometrics ; Pioneers of modern chemometrics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This is a first foray into the historical start and early years of chemometrics from about 1972 onwards. We have gathered interviews with three originators (Kowalski, Wold and Massart) as well as with a selected group of six other well-known chemometricians who gradually became active in the 1970s (Christie, Clementi, Hopke, Martens, Brown and Deming). The interviews include amongst a host of subjective recollections a succinct record of the key historical literature as highlighted by the interviewees' own rankings of ‘earliest’ and ‘best’.A discussion of the most general commonalities in these interviews together with other historical material is presented in the second part of the paper.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 355-360 
    ISSN: 0886-9383
    Keywords: Pattern recognition ; U.K. chemometrics usage ; Quantitative structure-activity relationships ; Artificial intelligence ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A survey of members of the U.K. QSAR Discussion Group has been made to determine the extent of use and development of chemometric and artificial intelligence (AI) methods in the analysis of multivariate quantitative structure-activity relationship (QSAR) data in the U.K. Chemometric methods were found to be well established in both industrial and educational establishments and there was significant method development occurring. AI methods were not employed to any great extent and the general level of interest in these techniques was low compared to chemometric methods. A requirement for more education in multivariate statistical methods and regression methods was indicated. A need for a user-friendly, comprehensive, commercially available multivariate statistical package containing multivariate stability testing and regression diagnostic methods was identified.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 361-377 
    ISSN: 0886-9383
    Keywords: Abstract factor analysis ; Exploratory data analysis ; Principal components ; Simulated equilibria ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract factor analyses were performed on databases consisting of simulated samples from aqueous equilbria. The program COMPLEX was used to generate equilibrium species in a system of three reactant metals and five reactant bases. Reactant concentrations and pH were drawn from random-normal distributions so that sample data vectors comprised a multivariate log-normal distribution of equilibrium concentrations. In addition, sample groups were created containing different distributions for pH and reactant concentrations.Equilibrium species were shown to contain variance contributed by change in pH among samples as well as change in reactant concentrations. Factor modelling revealed the qualitative relationships among the species and how the relationships change with pH. Factors also revealed those reactants containing variance in the data matrix. In some cases, reactant variance obscured relationships between pH and the equilibrium species.Since factor modelling of a simulated data matrix revealed the expected chemical equilibrium interactions, a potentially powerful tool exists for investigating the effects of outliers and error.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 301-302 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 305-331 
    ISSN: 0886-9383
    Keywords: Pyrolysis ; Mass spectroscopy ; Multivariate analysis ; Biological material identification ; Convexity ; Cones ; Subspaces ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This work addresses the classification of high-dimensional time-dependent pyrolysis mass spectra of biological samples. The aim was the detection and classification of biological agents, and the developed approach resembles mixture analysis. The data were projected on to a low-dimensional subspace using singular value decomposition. Then a convex cone was formed on this subspace, showing as its corners physically meaningful components of the sample. This technique enabled separation of a biological material signal largely independent of the absolute amount of sample. The detection of the presence of any biological material could be accomplished based on the convex cone alone, without other reference to the mass spectra. Automated clustering of samples was successfully carried out using a minimal spanning tree.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 8 (1994), S. 373-373 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 4 (1990), S. 389-412 
    ISSN: 0886-9383
    Keywords: Chemometrics ; Chemometrics Society ; History of chemometrics ; Pioneers of modern chemometrics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This is a first foray into the historical start and early years of chemometrics from about 1972 onwards. We have gathered interviews with three originators (Kowalski, Wold and Massart) as well as with a selected group of six other well-known chemometricians who gradually became active in the 1970s (Christie, Clementi, Hopke, Martens, Brown and Deming). The interviews include amongst a host of subjective recollections a succinct record of the key historical literature as highlighted by the interviewees' own rankings of ‘earliest’ and ‘best’.A discussion of the most general commonalities in these interviews together with other historical material is presented in the second part of the paper.
    Additional Material: 6 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    ISSN: 0886-9383
    Keywords: Discriminant analysis ; Size-exclusion chromatography ; Wheat proteins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Continuous digitalized signals such as spectra, electrophoregrams or chromatograms generally have a large number of data points and contain redundant information. It is therefore troublesome performing discriminant analysis without any preliminary selection of variables. A procedure for the application of canonical discriminant analysis (CDA) on this kind of data is studied. CDA can be presented as a succession of two principal component analyses (PCAs). The first is performed directly on the raw data and gives PC scores. The second is applied on the gravity centres of each qualitative group assessed on the normalized PC scores. A stepwise procedure for selection of the relevant PC scores is presented. The method has been tested on an illustrative collection of 165 size-exclusion high-performance (SE-HPLC) chromatograms of proteins of wheat belonging to 55 genotypes and grown in three locations. The discrimination of the growing locations was performed using seven to nine PC scores and gave more than 86% accurate classifications of the samples both in the training sets and the verification sets. The genotypes were also rather well identified, with more than 85% of the samples correctly classified. The studied method gives a way of assessing relevant mathematical distances between digitalized signals according to qualitative knowledge of the samples.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 0886-9383
    Keywords: Principal components ; Multiple and stepwise regression ; Non-parametric density and regression estimation ; Bootstrap inference ; Canonical correlation ; PLS regression ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A statistical study of the dependence between various critical fusion temperatures of a certain kind of coal and its chemical components is carried out. As well as using classical dependence techniques (multiple, stepwise and PLS regression, principal components, canonical correlation, etc.) together with the corresponding inference on the parameters of interest, non-parametric regression and bootstrap inference are also performed.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 197-209 
    ISSN: 0886-9383
    Keywords: proficiency test ; true value ; homogeneity robust statistic ; standard ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Profficiency tests raise two types of problems: (i) the homogeneity of a sample must be carefully checked before using it as a reference material; (ii) it is necessary to define a conventional reference value (RV) in order to rank participants. Since these topics are poorly addressed in the literature, a reference material was specially prepared in order to propose a procedure for verifying homogeneity and to establish whether the algorithms classically used to compute the conventional true value have an influence on the conclusion of the test.The homogeneity of the sample was not perfect and univariate and multivariate techniques were used to demonstrate some analytes can be suspected as heterogeneous. However, this was considered adequate for introducing the sample in a large proficiency test organized between four laboratory associations which regularly perform such tests. Altogether more than 3000 measurements were collected and eight algorithms were applied to compute the RV on 14 analytes. Thus is was possible to demonstrate that some of these algorithms are better adapted than others. It is also obvious that some analytes are better suited to proficiency testing.It can be concluded from this work that some effort towards standardization would be profitable to check homogeneity or to compute the RV, especially since the economic weight of proficiency testing is becoming even more important with the development of certification accreditation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 129-145 
    ISSN: 0886-9383
    Keywords: Multivariate calibration ; Biased regression ; Partial least squares (PLS) ; Principal component regression (PCR) ; Model validation ; Non-linear calibration ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: With the goal of understanding global chemical processes, environmental chemists have some of the most complex sample analysis problems. Multivariate calibration is a tool that can be applied successfully in many situations where traditional univariate analyses cannot. The purpose of this paper is to review multivariate calibration, with an emphasis being placed on the developments in recent years. The inverse and classical models are discussed briefly, with the main emphasis on the biased calibration methods. Principal component regression (PCR) and partial least squares (PLS) are discussed, along with methods for quantitative and qualitative validation of the calibration models. Non-linear PCR, non-linear PLS and locally weighted regression are presented as calibration methods for non-linear data. Finally, calibration techniques using a matrix of data per sample (second-order calibration) are discussed briefly.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 147-161 
    ISSN: 0886-9383
    Keywords: Digital filtering ; Real-time analysis ; Kalman filtering ; Infrared spectroscopy ; Principal components regression ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Real-time monitoring of pollutant levels from a mobile measuring platform requires fast, flexible data analysis methods. This paper reports a method for rapid analysis of passive remotely sensed infrared data with the aid of a Kalman filter. The background spectra produced by emission from the atmosphere are modelled at the start of the data collection sequence with a simple principal components model obtained by eigenanalysis of the initial ‘blank’ data taken with the spectrometer. The species of interest are included in the state space model by a separate measurement of their infrared spectra. It is demonstrated that for best filter performance in detecting the simulated pollutant species SF6 in the atmosphere, a filter model with two principal components describing the emission background works best. The filter ‘maps’ of SF6 closely follow the integrated spectral intensities measured after removal of suitable backgrounds.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 163-179 
    ISSN: 0886-9383
    Keywords: Principal component analysis ; Factor analysis ; Chemometrics ; Exploratory data analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Principal component analysis is used to examine large multivariate databases. The graphical approach to exploratory data analysis is described and illustrated with a single example of chemical composition data obtained on environmental dust particles. While the graphical approach to exploratory data analysis has certain advantages over the numerical procedures, the empirical approach described here should be viewed as complementary to the more robust treatments that statistical methodologies afford.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 181-192 
    ISSN: 0886-9383
    Keywords: Chemometrics ; Systems theory ; Experimental design ; Multivariate analysis ; Measurement science ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Chemometrics is defined as the application of mathematical and statistical methods to chemical systems. Systems theory is seen to be useful for organizing and categorizing the inputs to and outputs from chemical systems. Advances in measurement science in the 1950s and 1960s, particularly in analytical chemistry, created a need for a multivariate approach to data analysis. Early chemometrics emphasized the use of structure-finding methods for existing data sets. In many instances, data sets can be obtained from designed experiments. Such data sets are more likely to contain the desired information and the data can usually be acquired at less cost. Renewed interest in statistical process control will provide many new, more robust data sets in the future.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 193-199 
    ISSN: 0886-9383
    Keywords: Kalman filter ; Chemometrics ; 5-Br-PADAP ; Metallic ions ; Simultaneous spectrophotometric determination ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes the simultaneous determination of cobalt, nickel, copper, zinc and cadmium by spectrophotometry and the Kalman filter method. Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) react with 5-bromo-2-(2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) in the presence of cationic surfactant cetyl pyridinium bromide (CPB) to form five different coloured ternary complexes. The absorption curves of these complexes overlap severely in the scanning range 500-620 nm. The Kalman filter algorithm is successfully applied to resolve the overlapped absorption curves and therefore makes the simultaneous determination of these metallic ions possible without tedious pretreatment. The proposed method is applied to analyse the titled elements in synthetic samples and in environmental samples such as hair, fingernail and river water samples with satisfactory results.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 201-209 
    ISSN: 0886-9383
    Keywords: Uncertainty ; Step function ; Additive model ; Transformation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An additive model is used to express the observed value of a sample characteristic as the sum of the true sample characteristic and a value of the data collection error, commonly known as experimental error. The data uncertainty of the experimental results (or of a survey data set) is defined as the expected squared error. The expected squarred error may change with the sample characteristic, e.g. the error moment could be concentration-dependent. The relationship between the error variance and the analyte concentration may not be very distinct. In such a case the data transformation to stabilize the error moments may not be appropriate. A step function is proposed as an alternative way to represent the second moment of the error. The data uncertainty is defined as the weighted average of the step values of the second raw moment of the error, using the appropriate proportions of the routine samples as weights. The data uncertainties associated with the different data collection stages were evaluated by using regional soil survey data.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 211-225 
    ISSN: 0886-9383
    Keywords: Shot noise ; Expectation-maximization ; Regression ; Deconvolution ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple algorithm for deconvolution and regression of shot-noise-limited data is illustrated in this paper. The algorithm is easily adapted to almost any model and converges to the global optimum. Multiple-component spectrum regression, spectrum deconvolution and smoothing examples are used to illustrate the algorithm. The algorithm and a method for determining uncertainties in the parameters based on the Fisher information matrix are given and illustrated with three examples. An experimental example of spectrograph grating order compensation of a diode array solar spectroradiometer is given to illustrate the use of this technique in environmental analysis. The major advantages of the EM algorithm are found to be its stability, simplicity, conservation of data magnitude and guaranteed convergence.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 451-457 
    ISSN: 0886-9383
    Keywords: non-linear regression ; optimization ; robust methods ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Several robust regression methods, including a new proposal, are described and their properties discussed. Resistance to various types of outliers and non-normality is demonstrated. The techniques are applied to non-linear regression models from chemical kinetics and calibration. Optimization of the types of objective functions encountered when applying robust regression is considered.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 9 (1995), S. 471-481 
    ISSN: 0886-9383
    Keywords: batch prediction ; continuum regression ; multivariate calibration ; sequential prediction ; simultaneous prediction ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In analytical chemistry a single fitted calibration model is used repeatedly to predict the level of the analyte of interest for the specimens comprising the prediction set. Unlike the calibration (or training) set, which is often limited in size, the prediction set can be very large.In the case of multivariate calibration a number of methods such as PLS and PCR are commonly used to construct the calibration model. The set of instrumental measurements and the reference analyte level are available for each specimen in the calibration set. For specimens in the prediction set, only the instrumental measurements are available, since the problem is to predict the analyte level for these specimens. It is not widely recognized that predictions of the analyte levels for individual specimens can be improved by utilizing seemingly unrelated information from the instrumental measurements associated with the other members of the prediction set. In the case of PCR there exists a very straightforward procedure for doing this. A description of the various sources of prediction errors is provided to explain the ability of PCR to utilize this additional information. The use of PCR in this context is illustrated with both a synthetic and a real example.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
  • 94
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 291-298 
    ISSN: 0886-9383
    Keywords: Absorbance ratio ; Statistical confidence ; Quality control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Ratio measurements are commonly used to address a variety of analytical problems in environmental, forensic and pharmaceutical laboratories. In absorbance ratioing techniques, analytical chemists rely on the spectral features of the analyte(s) of interest. The absorbances at two wavelengths are monitored and the ratio of these two absorbances is computed. This ratio is then used to confirm the identity of the analyte(s) of interest, the purity of a product of the overlap of chromatographic peaks. These decisions often have far-reaching consequences (e.g. the identification of the source, biogenic or petrogenic, of hydrocarbons in biological tissues or water). Given the cost and the liabilities associated with such decisions, it is unfortunate that these ratios are seldom reported with any statistical confidence. The purpose of this study is to delineate the parameters that affect absorbance ratio measurements. The models that can be used to estimate the statistical confidence in these measurements are derived and evaluated experimentally. The results show that these models can estimate the relative standard deviations in absorbance ratios accurately. They can also estimate the effect of signal-to-noise ratio and the choice of wavelengths on the precision of absorbance ratios.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 299-308 
    ISSN: 0886-9383
    Keywords: Errors in variables ; Orthogonal regression ; Latent variables ; Acid rain ; Acidic deposition ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Techniques for testing for and estimating relative bias between two laboratories are developed and applied to a survey of the chemistry of streams in the United States. The design of the quality assurance program allows estimation of linear corrections for bias as well as testing of the hypothesis of linearity. Designs of this type are useful, but improvements are suggested.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 309-319 
    ISSN: 0886-9383
    Keywords: Confidence intervals ; Products of normal random variables ; Risk/exposure modeling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In many environmental applications, such as exposure assessment and risk modelling, the desired estimate is a random variable computed as the product of three independently distributed random variables. These variables may not necessarily have the same mean and variance. The method for finding the 100(1 - α)% confidence interval for the mean of the product random variable has been proposed by some practitioners as the product of the 100(1 - α)% confidence interval of the three means. In this paper we show that the distribution of the product of three independent normal variables is not normal. We find the mean and variance of the product distribution. Further, we show that although the mean of the product is equal to the product of the means, the product of the three confidence intervals is not a good approximation of the confidence intervals for the mean of the product variable. The confidence interval of the mean of the product variable may be estimated by computer simulation. An algorithm for estimating the confidence interval for the mean of the product random variable is given. The program implementing this algorithm is given as an appendix.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 321-331 
    ISSN: 0886-9383
    Keywords: Screening ; Ground-water quality ; Monitoring ; Volatile organic compounds (VOCs) ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It is shown that the presence of 31-35 commonly measured volatile organic compounds (VOCs) in ground water can be detected with small error rates by using screening methods which analyze for a subset of such VOCs. A study of selected data sets indicates that analytical determinations of only from two to eight VOCs will suffice to detect 95% of all VOC hits. It is also shown that a serially optimal algorithm for selecting the VOCs for screening is very nearly as accurate as a globally optimal algorithm and much easier to implement. These conclusions are supported by empirical evidence from two drinking-water data sets and one hazardous waste site data set. Additional research areas are also outlined.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991) 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. i 
    ISSN: 0886-9383
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Chemometrics 5 (1991), S. 333-343 
    ISSN: 0886-9383
    Keywords: Rank estimation ; Bootstrap resampling ; Canonical correlation ; Excitation-emission matrix ; Singular value decomposition ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Rank estimation by canonical correlation analysis in multivariate statistics has been proposed as an alternative approach for estimating the number of components in a multicomponent mixture. A methodological turning point of this new approach is that it focuses on the difference in structure rather than in magnitude in characterizing the difference between the signal and the noise. This structural difference is quantified through the analysis of canonical correlation, which is a well-established data reduction technique in multivariate statistics. Unfortunately, there is a price to be paid for having this structural difference: at least two replicate data matrices are needed to carry out the analysis.In this paper we continue to explore the potential and to extend the scope of the canonical correlation technique. In particular, we propose a bootstrap resampling method which makes it possible to perform the canonical correlation analysis on a single data matrix. Since a robust estimator is introduced to make inference about the rank, the procedure may be applied to a wide range of data without any restriction on the noise distribution. Results from real as well as simulated mixture samples indicate that when used in conjunction with this resampling method, canonical correlation analysis of a single data matrix is equally efficient as of replicate data matrices.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...