Study on dimensionless criterion of fracture of closed pipe due to freezing of water

Studie über ein dimensionsloses Kriterium zur Vorhersage des Berstens eines geschlossenen Rohres durch frierendes Wasser

  • Published:
Wärme - und Stoffübertragung Aims and scope Submit manuscript

Abstract

The pressure rise due to freezing of water enclosed in pipes has been studied, by means of theoretical computation and experiments, under the various heat transfer conditions and ambient temperatures, taking deformation of pipe walls into account. It has been found that the presented models well represent the actual phenomena and dimensionless parameters proposed are effective for correlating the pressure rises, the conditions of heat transfer, dimensions of the pipes. The tangential stress has been analyzed in dimensionless form to clarify its dependabilities on the modified Biot number and the ratio of thickness of a pipe wall and its radius. It has also shown thatF crit, the critical Fourier number, can be considerably increased by introducing a void area at the center of pipes and the criterion of freezing fracture of pipes can be expressed as a combination of the dimensionless parameters presented in the report.

Zusammenfassung

Es wurde der Druckanstieg bei Einfrieren eines in Rohren eingeschlossenen Wassers experimentell und mittels theoretischer Berechnungen bei unterschiedlichen Werten von Wärmübergang und Umgebungstemperatur und unter Berücksichtigung der Verformung der Rohrwand berechnet. Dabei konnte festgestellt werden, daß das vorgestellte Modell die tatsächlichen Phänomene gut wiedergibt und die vorgeschlagenen dimensionslosen Parameter für die Berechnung des Druckanstieges und die Berücksichtigung der Wärmeübergangsbedingungen geeignet sind. Die Tangentialspannung wurde in dimensionsloser Form analysiert, um die Abhängigkeit von der modifizierten Biot-Zahl und von dem Verhältnis von Wandstärke zu Radius des Rohres zu klären. Es wird auch gezeigt, daß die kritische modifizierte Fourier-Zahl beträchtlich erhöht werden kann, wenn man eine Gaszone im Zentrum des Rohres einführt. Weiterhin wird gezeigt, daß das Kriterium für den Einfrierbruch des Rohres als Kombination dimensionsloser Parameter ausgedrückt werden kann.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. London, A. L.; Seban, R. A.: Rate of ice formation. Trans. ASME, (1943) 771

  2. Gilpin, R. R.: The effect of dendritic ice formation in water pipes. Int. J. Heat Mass Transf. 18 (1975) 1307

    Google Scholar 

  3. Mulligan, J. C.; Jones, D. D.: Experiments on heat transfer and pressure drop in a horizontal tube with internal solidification. Int. J. Heat Mass Transf. 19 (1976) 213

    Google Scholar 

  4. Sugawara, M.; Ota, T.; Yamada, E.: Pressure increase with freezing of water in a closed circular tube (in Japanese). Trans. JSME 439 (1983) 741

    Google Scholar 

  5. Sugawara, M.; Seki, N.: Freezing of water in a closed circular tube. Wärme-Stoffübertrag. 17 (1983) 187

    Google Scholar 

  6. Katto, Y.; Nishimura, H.: Heat conduction with phase change (in Japanese). Trans. JSME 165 (1960) 715

    Google Scholar 

  7. Horiuchi, Y.; Maeno, K.: Investigation of the pressure increase with freezing of water. Preprint of the Conference of Japan Soc. of Snow and Ice 1980, p. 66

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Oiwake, S., Saito, H., Inaba, H. et al. Study on dimensionless criterion of fracture of closed pipe due to freezing of water. Warme- und Stoffubertragung 20, 323–328 (1986). https://doi.org/10.1007/BF01002423

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01002423

Keywords

Navigation