Journal Description
Chemosensors
Chemosensors
is an international, scientific, peer-reviewed, open access journal on the science and technology of chemical sensors and related analytical methods and systems, published monthly online by MDPI.
- Open Access— free for readers, with article processing charges (APC) paid by authors or their institutions.
- High Visibility: indexed within Scopus, SCIE (Web of Science), CAPlus / SciFinder, Inspec, and other databases.
- Journal Rank: JCR - Q1 (Instruments & Instrumentation) / CiteScore - Q2 (Analytical Chemistry)
- Rapid Publication: manuscripts are peer-reviewed and a first decision is provided to authors approximately 17.9 days after submission; acceptance to publication is undertaken in 2.8 days (median values for papers published in this journal in the second half of 2023).
- Recognition of Reviewers: reviewers who provide timely, thorough peer-review reports receive vouchers entitling them to a discount on the APC of their next publication in any MDPI journal, in appreciation of the work done.
Impact Factor:
4.2 (2022);
5-Year Impact Factor:
4.2 (2022)
Latest Articles
Biosensors for Food Mycotoxin Determination: A Comparative and Critical Review
Chemosensors 2024, 12(6), 92; https://doi.org/10.3390/chemosensors12060092 (registering DOI) - 30 May 2024
Abstract
The need for performant analytical methodologies to assess mycotoxins is vital, given the negative health impact of these compounds. Biosensors are analytical devices that consist of a biological element for recognizing the analyte and a transducer, which translates the biorecognition event into a
[...] Read more.
The need for performant analytical methodologies to assess mycotoxins is vital, given the negative health impact of these compounds. Biosensors are analytical devices that consist of a biological element for recognizing the analyte and a transducer, which translates the biorecognition event into a signal proportional to the analyte concentration. The biorecognition elements can be enzymes, antibodies, or DNA fragments. The modalities of detection can be optical, electrochemical, thermal, or mass-sensitive. These analytical tools represent viable alternatives to laborious, expensive traditional methods and are characterized by specificity given by the biorecognition element, sensitivity, fast response, portability, multi-modal detection, and the possibility of in situ application. The present paper focuses on a comprehensive view, enriched with a critical, comparative perspective on mycotoxin assay using biosensors. The use of different biorecognition elements and detection modes are discussed comparatively. Nanomaterials with optical and electrochemical features can be exploited in association with a variety of biorecognition elements. Analytical parameters are reviewed along with a broad range of applications.
Full article
(This article belongs to the Special Issue Feature Review Papers in Chemical/Bio-Sensors and Analytical Chemistry in 2024)
►
Show Figures
Open AccessArticle
A “Turn-Off” Pyrene-Based Ligand as a Fluorescent Sensor for the Detection of Cu2+ and Fe2+ Ions: Synthesis and Application in Real Water Samples, Logic Gate Construction, and Bio-Imaging
by
Bhavana G. Gowda, Muzaffar Iqbal and Shiva Prasad Kollur
Chemosensors 2024, 12(6), 91; https://doi.org/10.3390/chemosensors12060091 (registering DOI) - 30 May 2024
Abstract
Herein, we report the synthesis and characterization of a novel Schiff base ligand, (Z)-5-((pyren-1-ylmethylene)amino)-2,4-dihydro-3H-pyrazol-3-one (PMDP). The characterization of ligand PMDP was carried out using ESI-MS, 1H NMR, and UV–Visible spectroscopic techniques. As a probe, PMDP displayed a detectable, colorimetric colour
[...] Read more.
Herein, we report the synthesis and characterization of a novel Schiff base ligand, (Z)-5-((pyren-1-ylmethylene)amino)-2,4-dihydro-3H-pyrazol-3-one (PMDP). The characterization of ligand PMDP was carried out using ESI-MS, 1H NMR, and UV–Visible spectroscopic techniques. As a probe, PMDP displayed a detectable, colorimetric colour shift in the presence of Cu2+ and Fe2+ ions. The solution was seen to have a light brown colour and to exhibit a fluorometric “turn off” response when Cu2+ and Fe2+ ions were present in a DMSO solution (HEPES 0.01 M, pH = 7.4) at room temperature. Job’s plot revealed that the PMDP binding ratio to Cu2+ and Fe2+ ions was in 1:2 ratio. In contrast to the other metal ions (Cd2+, Mn2+, Co2+, Na+, Ni2+, Cu+, Fe3+, Hg2+, Mg2+, Zn2+, K+, and V5+), the synthesised probe showed exceptional sensitivity and selectivity for detecting Cu2+ and Fe2+ metal ions. The results indicate that the detection limits for Cu2+ and Fe2+ are 0.42 μM and 0.51 μM, respectively. Furthermore, PMDP was efficiently utilised for the quantitative analysis of Cu2+ and Fe2+ in real water samples, RGB colour values in smart phones, logic gate construction, and cell imaging in HeLa cells.
Full article
(This article belongs to the Special Issue Colorimetric and Fluorescent Sensors: Current Status and Future Development)
Open AccessArticle
Enhancement of H2 Gas Sensing Using Pd Decoration on ZnO Nanoparticles
by
Jin-Young Kim, Kyeonggon Choi, Seung-Wook Kim, Cheol-Woo Park, Sung-Il Kim, Ali Mirzaei, Jae-Hyoung Lee and Dae-Yong Jeong
Chemosensors 2024, 12(6), 90; https://doi.org/10.3390/chemosensors12060090 - 27 May 2024
Abstract
Hydrogen (H2) gas, with its high calorimetric combustion energy and cleanness, is a green source of energy and an alternative to fossil fuels. However, it has a small kinetic diameter, with high diffusivity and a highly explosive nature. Hence, the reliable
[...] Read more.
Hydrogen (H2) gas, with its high calorimetric combustion energy and cleanness, is a green source of energy and an alternative to fossil fuels. However, it has a small kinetic diameter, with high diffusivity and a highly explosive nature. Hence, the reliable detection of H2 gas is essential in various fields such as fuel cells. Herein, we decorated ZnO nanoparticles (NPs) with Pd noble metal NPs, using UV irradiation to enhance their H2 gas-sensing performance. The synthesized materials were fully characterized in terms of their phases, morphologies, and chemical composition. Then, the sensing layer was deposited on the electrode-patterned glass substrate to make a transparent sensor. The fabricated transparent gas sensor was able to detect H2 gas at various temperatures and humidity levels. At 250 °C, the sensor exhibited the highest response to H2 gas. As a novelty of the present study, we successfully detected H2 gas in mixtures of H2/benzene and H2/toluene gases. The enhanced H2 gas response was related to the catalytic effect of Pd, the formation of heterojunctions between Pd and ZnO, the partial reduction of ZnO to Zn in the presence of H2 gas, and the formation of PdHx. With a high performance in a high response, good selectivity, and repeatability, we believe that the sensor developed in this study can be a good candidate for practical applications where the detection of H2 is necessary.
Full article
(This article belongs to the Special Issue Gas Sensors and Electronic Noses for the Real Condition Sensing)
Open AccessArticle
Superoxide Dismutase Detection on Silver Nanostructured Substrates through Surface-Enhanced Spectroscopic Techniques
by
Anastasia Kanioura, Georgia Geka, Ioannis Kochylas, Vlassis Likodimos, Spiros Gardelis, Anastasios Dimitriou, Nikolaos Papanikolaou, Sotirios Kakabakos and Panagiota Petrou
Chemosensors 2024, 12(6), 89; https://doi.org/10.3390/chemosensors12060089 - 25 May 2024
Abstract
Oxidative stress refers to the overproduction of reactive oxygen species and is often associated with numerous pathological conditions. Superoxide dismutase (SOD) is a widely used enzyme for evaluating oxidative stress, with numerous methods being developed for its detection in biological specimens like blood,
[...] Read more.
Oxidative stress refers to the overproduction of reactive oxygen species and is often associated with numerous pathological conditions. Superoxide dismutase (SOD) is a widely used enzyme for evaluating oxidative stress, with numerous methods being developed for its detection in biological specimens like blood, urine, and saliva. In this study, a simple metal-assisted chemical etching method was employed for the fabrication of nanostructured silicon surfaces decorated with either silver dendrites or silver aggregates. Those surfaces were used as substrates for the immunochemical determination of SOD in synthetic saliva through surface-enhanced Raman spectroscopy (SERS) and surface-enhanced fluorescence (SEF). The immunoassay was based on a 3-step competitive assay format, which included, after the immunoreaction with the specific anti-SOD antibody, a reaction with a biotinylated secondary antibody and streptavidin. Streptavidin labeled with peroxidase was used in combination with a precipitating tetramethylbenzidine substrate for detection through SERS, whereas for SEF measurements, streptavidin labeled with the fluorescent dye Rhodamine Red-X was utilized. Both immunoassays were sensitive, with a detection limit of 0.01 μg/mL and a linear dynamic range from 0.03 to 3.3 μg/mL, enabling the evaluation of the oxidative stress status of an organism.
Full article
(This article belongs to the Special Issue Application of Luminescent Materials for Sensing)
►▼
Show Figures
Figure 1
Open AccessReview
The Developments on Lateral Flow Immunochromatographic Assay for Food Safety in Recent 10 Years: A Review
by
Peng Wang, Jinyan Li, Lingling Guo, Jiaxun Li, Feng He, Haitao Zhang and Hai Chi
Chemosensors 2024, 12(6), 88; https://doi.org/10.3390/chemosensors12060088 - 24 May 2024
Abstract
Food safety inspections are an essential aspect of food safety monitoring. Rapid, accurate, and low-cost food analysis can considerably increase the efficiency of food safety inspections. The lateral flow immunochromatographic assay (LFIA) technique has recently grown in popularity due to its ease of
[...] Read more.
Food safety inspections are an essential aspect of food safety monitoring. Rapid, accurate, and low-cost food analysis can considerably increase the efficiency of food safety inspections. The lateral flow immunochromatographic assay (LFIA) technique has recently grown in popularity due to its ease of use and high efficiency. It is currently commonly utilized in food inspection. In this review, we briefly introduce the principle and classification of LFIA, critically discuss the recent application status of LFIA in food contaminantion detection, and finally propose that artificial intelligence and information technology will further advance the development of LFIA in the field of food safety monitoring.
Full article
(This article belongs to the Special Issue Low-Cost Chemosenors for Applications in Environment, Health, Food, and Industry Process Control)
►▼
Show Figures
Figure 1
Open AccessArticle
Controlled Insertion of Silver Nanoparticles in LbL Nanostructures: Fine-Tuning the Sensing Units of an Impedimetric E-Tongue
by
Maria Helena Gonçalves, Maria Luisa Braunger, Anerise de Barros, Rafael C. Hensel, Julianna G. Dalafini, Italo O. Mazali, Leonardo M. Corrêa, Daniel Ugarte, Antonio Riul Jr and Varlei Rodrigues
Chemosensors 2024, 12(6), 87; https://doi.org/10.3390/chemosensors12060087 - 24 May 2024
Abstract
Silver nanoparticles (AgNPs) possess unique characteristics ideal for enhancing device sensitivity, primarily due to their high surface-to-volume ratio facilitating heightened interaction with analytes. Integrating AgNPs into polymers or carbon-based materials results in nanocomposites with synergistic properties, enabling the detection of minute changes in
[...] Read more.
Silver nanoparticles (AgNPs) possess unique characteristics ideal for enhancing device sensitivity, primarily due to their high surface-to-volume ratio facilitating heightened interaction with analytes. Integrating AgNPs into polymers or carbon-based materials results in nanocomposites with synergistic properties, enabling the detection of minute changes in the environment across various applications. In this study, we investigate the adsorption kinetics of AgNPs within multilayered layer-by-layer (LbL) structures, specifically examining the impact of AgNPs concentration in the LbL film formation that is further explored as sensing units in an impedimetric microfluidic e-tongue. Although absorption kinetic studies are infrequent, they are crucial to optimize the AgNPs adsorption and distribution within LbL structures, significantly influencing upcoming applications. Through systematic variation of AgNPs concentration within identical LbL architectures, we applied the films as sensing units in a microfluidic e-tongue capable of distinguishing food enhancers sharing the umami taste profile. Across all tested scenarios, our approach consistently achieves robust sample separation, evidenced by silhouette coefficient, principal component analyses, and long-term stability. This work contributes to exploring controlled nanomaterial-based developments, emphasizing the importance of precise parameter control for enhanced sensor performance across diverse analytical applications.
Full article
(This article belongs to the Section Materials for Chemical Sensing)
►▼
Show Figures
Figure 1
Open AccessArticle
All-Solid-State Potentiometric Sensor Based on Graphene Oxide as Ion-to-Electron Transducer for Nitrate Detection in Water Samples
by
Renato L. Gil, Laura Rodriguez-Lorenzo, Begoña Espiña and Raquel B. Queirós
Chemosensors 2024, 12(6), 86; https://doi.org/10.3390/chemosensors12060086 - 22 May 2024
Abstract
Graphene oxide (GO) was used as an ion-to-electron transducer for all-solid-state nitrate electrodes based on an alkyl ammonium salt as the sensing element. Commercially available carbon screen-printed electrodes modified with GO were used as conductive substrates, whose morphology and distribution along the surface
[...] Read more.
Graphene oxide (GO) was used as an ion-to-electron transducer for all-solid-state nitrate electrodes based on an alkyl ammonium salt as the sensing element. Commercially available carbon screen-printed electrodes modified with GO were used as conductive substrates, whose morphology and distribution along the surface were evaluated by scanning electron microscopy and Raman spectroscopy. The potentiometric performance of the GO-based electrodes revealed a Nernstian slope of −53.5 ± 2.0 mV decade−1 (R2 = 0.9976 ± 0.0015) in the range from 3.0 × 10−6 to 10−2 M and a lower limit of detection of 1.9 × 10−6 M. An impressive reproducibility between equally prepared electrodes (n = 15) was demonstrated by a variation of <6% for the calibration parameters. Constant current chronopotentiometry and water layer tests were used to evaluate the potential signal stability, providing similar performance to previously published works with graphene-based ion-selective electrodes. Notably, the GO-based sensors showed the absence of a water layer, a long-term drift of 0.3 mV h−1, and a stable performance (LOD and sensitivity) over 3 months. The applicability of the proposed sensors was demonstrated in determining nitrate levels in water samples with great accuracy, yielding recovery values from 87.8 to 107.9%, and comparable (p > 0.05) results to a commercial nitrate probe. These findings demonstrate the use of GO as an alternative ion-to-electron transducer for the fabrication of all-solid-state potentiometric electrodes.
Full article
(This article belongs to the Special Issue Carbon Nanomaterials and Related Materials for Sensing Applications, Volume II)
►▼
Show Figures
Graphical abstract
Open AccessReview
Defect Engineering in Transition Metal Dichalcogenide-Based Gas Sensors
by
Xiaqing Fu, Zirui Qiao, Hangyu Zhou and Dan Xie
Chemosensors 2024, 12(6), 85; https://doi.org/10.3390/chemosensors12060085 - 21 May 2024
Abstract
Since the discovery of innovative two-dimensional (2D) materials, significant efforts have been dedicated to exploring their intriguing properties and emerging applications. Among all candidates, transition metal dichalcogenides (TMDs) have proven to be exceptional for gas sensing, while defects engineering has been introduced to
[...] Read more.
Since the discovery of innovative two-dimensional (2D) materials, significant efforts have been dedicated to exploring their intriguing properties and emerging applications. Among all candidates, transition metal dichalcogenides (TMDs) have proven to be exceptional for gas sensing, while defects engineering has been introduced to modify the pristine TMDs for better gas sensing performances. In this review, we systematically summarize types of defects, advanced characterization techniques, and state-of-the-art controllable synthetic methods. Various types of defects in TMDs can induce diverse changes in chemical and electron structures, which are closely correlated with gas sensing ability. Therefore, connections between defects and gas sensing mechanisms and performances have been addressed based on both defect categories and electron affinity of gases. This review will be a guide for researchers in defective materials and open up the field of precisely synthesis chemistry and deepen the understanding of the underlying effects of defects in other 2D materials.
Full article
(This article belongs to the Special Issue Emerging 2D Materials for Sensing Applications)
Open AccessArticle
Hydrothermally Synthesized Cerium Phosphate with Functionalized Carbon Nanofiber Nanocomposite for Enhanced Electrochemical Detection of Hypoxanthine
by
Prashant K. Kasare and Sea-Fue Wang
Chemosensors 2024, 12(5), 84; https://doi.org/10.3390/chemosensors12050084 - 16 May 2024
Abstract
This work presents the detection of hypoxanthine (HXA), a purine derivative that is similar to nucleic acids who overconsumption can cause health issues, by using hydrothermally synthesized cerium phosphate (CePO4) followed by a sonochemical approach for CePO4 decorated with a
[...] Read more.
This work presents the detection of hypoxanthine (HXA), a purine derivative that is similar to nucleic acids who overconsumption can cause health issues, by using hydrothermally synthesized cerium phosphate (CePO4) followed by a sonochemical approach for CePO4 decorated with a functionalized carbon nanofiber (CePO4@f-CNF) nanocomposite. The formation of the nanocomposite was confirmed with X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive spectroscopy (EDS). A CePO4@f-CNF nanocomposite is used to modify a glassy carbon electrode (GCE) to analyze the electrochemical detection of HXA. Cyclic voltammetry (CV), Electrochemical impedance spectroscopy (EIS), and Differential pulse voltammetry (DPV) were used to examine the electrochemical properties of the composite. As a result, the modified electrode exhibits a larger active surface area (A = 1.39 cm2), a low limit of detection (LOD) at 0.23 µM, a wide linear range (2.05–629 µM), and significant sensitivity. Therefore, the CePO4@f-CNF nanocomposite was used to study the real-time detection in chicken and fish samples, and it depicted significant results.
Full article
(This article belongs to the Special Issue Electrochemical Sensors and Biosensors for Environmental Detection)
►▼
Show Figures
Figure 1
Open AccessArticle
Influence of pH on Room-Temperature Synthesis of Zinc Oxide Nanoparticles for Flexible Gas Sensor Applications
by
Fazia Mechai, Ahmad Al Shboul, Mohand Outahar Bensidhoum, Hossein Anabestani, Mohsen Ketabi and Ricardo Izquierdo
Chemosensors 2024, 12(5), 83; https://doi.org/10.3390/chemosensors12050083 - 16 May 2024
Abstract
This research contributes to work on synthesizing zinc oxide nanoparticles (ZnO NPs) at room temperature (RT) and their utilization in flexible gas sensors. RT ZnO NP synthesis with a basicity solution (pH ≈ 13) demonstrates an efficient method for synthesizing well-crystalline ZnO NPs
[...] Read more.
This research contributes to work on synthesizing zinc oxide nanoparticles (ZnO NPs) at room temperature (RT) and their utilization in flexible gas sensors. RT ZnO NP synthesis with a basicity solution (pH ≈ 13) demonstrates an efficient method for synthesizing well-crystalline ZnO NPs (RT.pH13) comparable to those synthesized by the hydrothermal method (hyd.C). The RT.pH13 achieved a high thermal stability with minimal organic reside impurities (~4.2 wt%), 30–80 nm particle size distribution, and a specific surface area (14 m2 g−1). The synthesized pre- and post-calcinated RT.pH13 NPs were then incorporated into flexible sensors for gas sensing applications at ambient conditions (RT and relative humidity of 30–50%). The pre-calcinated ZnO-based sensor (RT.pH13) demonstrated superior sensitivity to styrene and acetic acid and lower sensitivity to dimethyl-6-octenal. The calcinated ZnO-based sensor (RT.pH13.C) exhibited lower sensitivity to styrene and acetic acid, but heightened sensitivity to benzene, acetone, and ethanol. This suggests a correlation between sensitivity and structural transformations following calcination. The investigation of the sensing mechanisms highlighted the role of surface properties in the sensors’ affinity for specific gas molecules and temperature and humidity variations. The study further explored the sensors’ mechanical flexibility, which is crucial for flexible Internet of Things (IoT) applications.
Full article
(This article belongs to the Special Issue Advances in Gas Sensors and their Application)
►▼
Show Figures
Graphical abstract
Open AccessArticle
Synergistic Enhancement Effect of Ag/rGO as SERS Platform for Capture and Trace Detection of Fenvalerate Molecules
by
Minghui Yu, Chongyang Qin, Zhi Yu, Biao Sun, Dejiang Ni, De Zhang and Pei Liang
Chemosensors 2024, 12(5), 82; https://doi.org/10.3390/chemosensors12050082 - 16 May 2024
Abstract
Surface-enhanced Raman scattering (SERS) provides an alternative rapid detection method for pesticide residues in food, but fenvalerate possesses poor affinity to the novel metal substrate, thus restricting its analysis. To break this bottleneck, a SERS-active platform with an Ag/rGO composite structure was engineered
[...] Read more.
Surface-enhanced Raman scattering (SERS) provides an alternative rapid detection method for pesticide residues in food, but fenvalerate possesses poor affinity to the novel metal substrate, thus restricting its analysis. To break this bottleneck, a SERS-active platform with an Ag/rGO composite structure was engineered using a facile method for fenvalerate detection. Ag nanoparticles with a 60 nm diameter can grow evenly on the top and bottom of rGO layers under intense ultrasonic oscillation, and rGO in hybrid material acts as an ideal hotspot holder between the gaps of Ag nanoparticles, not only allowing the interaction area to be enhanced both electromagnetically and chemically but also enabling the capture and enrichment of fenvalerate pesticide molecules into the “hotspot” area to improve detection sensitivity. Ag/rGO composite substrate possesses superior SERS performance with an ultralow detectable concentration of 4-aminothiophenol (10−10 M) and good reproducibility, endowing the material with a better enhancement effect than pure Ag nanoparticles. When used as the SERS substrate for fenvalerate detection, Ag/rGO composite material showed excellent performance in both experiments and theoretical calculation, with the limit of detection (LOD) of fenvalerate being as low as 1.69 × 10−5 mg/kg and a detection model with an R2 of 99.2%, demonstrating its exciting potential as a SERS substrate for pesticides detection.
Full article
(This article belongs to the Special Issue Recent Advances in Optical Chemo- and Biosensors)
►▼
Show Figures
Figure 1
Open AccessReview
Conducting Polymers in Amperometric Sensors: A State of the Art over the Last 15 Years with a Focus on Polypyrrole-, Polythiophene-, and Poly(3,4-ethylenedioxythiophene)-Based Materials
by
Maria I. Pilo, Gavino Sanna and Nadia Spano
Chemosensors 2024, 12(5), 81; https://doi.org/10.3390/chemosensors12050081 - 11 May 2024
Abstract
Conducting polymers are used in a wide range of applications, especially in the design and development of electrochemical sensors. Their main advantage, in this context, is their ability to efficiently modify an electrode surface using the direct polymerization of a suitable monomer in
[...] Read more.
Conducting polymers are used in a wide range of applications, especially in the design and development of electrochemical sensors. Their main advantage, in this context, is their ability to efficiently modify an electrode surface using the direct polymerization of a suitable monomer in an electrochemical cell, or by physical coating. Additionally, the conducting polymers can be mixed with further materials (metal nanoparticles, carbonaceous materials) to enhance conductivity and analytical features (linear range, limit of detection, sensitivity, and selectivity). Due to their characteristics, conducting polymer-based amperometric sensors are applied to the determination of different organic and inorganic analytes. A view of recent advances in this field focusing on pyrrole, thiophene, and 3,4-ethylenedioxythiophene as starting materials is reported.
Full article
(This article belongs to the Special Issue Recent Advances in Electrode Materials for Electrochemical Sensing)
►▼
Show Figures
Figure 1
Open AccessArticle
A Naked-Eye Colorimetric Ratio Method for the Selective and Sensitive Detection of L-Cys Based on a Silver Nanoflakes–Chromium (III) Ion System
by
Xi Zhang, Yunyi Zhang, Yuwei Gu, Junyu Zhou, Ming Li and Jian Qi
Chemosensors 2024, 12(5), 80; https://doi.org/10.3390/chemosensors12050080 - 11 May 2024
Abstract
As a necessary sulfhydryl amino acid, L-cysteine (L-Cys) maintains many physiological functions in the biological system. However, abnormal L-Cys levels can cause a variety of diseases. In our work, a highly sensitive and selective assay has been developed for sensing L-Cys using the
[...] Read more.
As a necessary sulfhydryl amino acid, L-cysteine (L-Cys) maintains many physiological functions in the biological system. However, abnormal L-Cys levels can cause a variety of diseases. In our work, a highly sensitive and selective assay has been developed for sensing L-Cys using the morphological transformation of silver-based materials induced by Cr3+. In this sensing system, Cr3+ could etch the silver nanoflakes into silver nanoparticles, accompanied by a change in absorbance, which decreases at 395 nm, creates a new peak at 538 nm, and keeps increasing the absorbance with the addition of Cr3+ concentration. Meanwhile, under the naked eye, the solution color changes from bright yellow to dark purple. Because of the strong affinity between L-Cys and Cr3+, L-Cys could inhibit the induction of Cr3+ on silver-based materials, thereby preventing changes in the configuration, absorption spectrum, and color of silver-based materials. Taking advantage of this point, we can quantitatively detect the concentration of L-Cys. A linear relationship between the absorbance ratio (A538 nm/A395 nm) and L-Cys concentration was found in the range of 0.1–0.9 μM, and the detection limit was 41.2 nM. The strategy was applied to measure L-Cys spiked in beer and urine samples, with recovery from 93.80 to 104.03% and 93.33% to 107.14% and RSD from 0.89 to 2.40% and 1.80% to 6.78%, respectively. This detection strategy demonstrates excellent selectivity and sensitivity, which makes it a practical and effective method for the detection of L-Cys in real samples.
Full article
(This article belongs to the Special Issue Low-Cost Chemosenors for Applications in Environment, Health, Food, and Industry Process Control)
►▼
Show Figures
Figure 1
Open AccessArticle
Synthesis, Spectral Characteristics, Sensing Properties and Microbiological Activity of New Water-Soluble 4-Sulfo-1,8-naphthalimides
by
Awad I. Said, Desislava Staneva, Evgenia Vasileva-Tonkova, Petar Grozdanov, Ivanka Nikolova, Radostina Stoyanova, Albena Jordanova and Ivo Grabchev
Chemosensors 2024, 12(5), 79; https://doi.org/10.3390/chemosensors12050079 - 9 May 2024
Abstract
A new water-soluble polyamidoamine (PAMAM) dendrimer modified with 4-sulfo-1,8-naphthalimide (DSNI) and its monomeric structural analogue (MSDI) were synthesized. Their photophysical properties were investigated in organic solvents of different polarities and aqueous solutions. The effect of pH on fluorescence intensity was determined. It was
[...] Read more.
A new water-soluble polyamidoamine (PAMAM) dendrimer modified with 4-sulfo-1,8-naphthalimide (DSNI) and its monomeric structural analogue (MSDI) were synthesized. Their photophysical properties were investigated in organic solvents of different polarities and aqueous solutions. The effect of pH on fluorescence intensity was determined. It was found that the dendrimer emits blue fluorescence in an acidic medium, which is quenched in an alkaline environment. This phenomenon is due to the possibility of suppression of nonradiative photoinduced electron transfer in acidic media. The influence of different metal ions (Cu2+, Pb2+, Sn2+, Sr2+, Mg2+, Ba2+, Co2+, Hg2+, Zn2+, Ni2+, Fe3+, Al3+) and anions (CN−, S2−, S2O52−, HPO42−, H2PO4−, F−, CH3COO−, NO2−, CO32−, SO42−) on the intensity of the emitted fluorescence was studied. Quenching was only found in the presence of Cu2+. This makes the dendrimer suitable for determining copper ions in water solutions in the presence of other metal ions and anions. Additionally, DSNI was used as a ligand to obtain a stable copper complex, the structure of which was investigated by electron paramagnetic resonance (EPR), infrared spectrum, and elemental analysis. Two copper ions were found to form a complex with one dendrimer. The in vitro microbiological activity of the new compounds against bacteria Pseudomonas aeruginosa and two viruses HRSV-2 and HAdV-5 was investigated. With a view to obtaining antibacterial and anti-viral textiles, cotton fabrics were treated with the three compounds, and then their activity against the same microbial strains was investigated. It was found that the microbiological activity was preserved after the application of the new compounds to the cotton fabrics.
Full article
(This article belongs to the Special Issue Chemosensors in Biological Challenges, Volume II)
►▼
Show Figures
Graphical abstract
Open AccessReview
Chemiresistive Materials for Alcohol Vapor Sensing at Room Temperature
by
Anna Maria Laera and Michele Penza
Chemosensors 2024, 12(5), 78; https://doi.org/10.3390/chemosensors12050078 - 7 May 2024
Abstract
The development of efficient sensors able to detect alcoholic compounds has great relevance in many fields including medicine, pharmaceuticals, food and beverages, safety, and security. In addition, the measurements of alcohols in air are significant for environmental protection because volatile alcohols can have
[...] Read more.
The development of efficient sensors able to detect alcoholic compounds has great relevance in many fields including medicine, pharmaceuticals, food and beverages, safety, and security. In addition, the measurements of alcohols in air are significant for environmental protection because volatile alcohols can have harmful effects on human health not only through ingestion, but also through inhalation or skin absorption. The analysis of alcohols in breath is a further expanding area, being employed for disease diagnoses. The analyses performed by using chromatography, mass-spectrometry, nuclear magnetic resonance, ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, or Raman spectroscopy often require complex sampling and procedures. As a consequence, many research groups have focused their efforts on the development of efficient portable sensors to replace conventional methods and bulky equipment. The ability to operate at room temperature is a key factor in designing portable light devices suitable for in situ real-time monitoring. In the present review, we provide a survey of the recent literature on the most efficient chemiresistive materials for alcohol sensing at room temperature. Remarkable gas-sensing performances have mainly been obtained by using metal oxides semiconductors (MOSs), metal organic frameworks (MOFs), 2D materials, and polymers. Among 2D materials, we mainly consider graphene-based materials, graphitic carbon nitride, transition metal chalcogenides, and MXenes. We discuss scientific advances and innovations published in the span of the last five years, focusing on sensing mechanisms.
Full article
(This article belongs to the Special Issue Innovative Nanomaterials-Based Chemosensor Devices for Air Quality Monitoring)
►▼
Show Figures
Figure 1
Open AccessArticle
Liquid-Phase Exfoliated Graphene and Polytetrafluoroethylene for Highly Durable and Reusable Chemical Leak Detection Sensors
by
Najaf Rubab, Eunbee Sohn, Won-Seok Kang and TaeYoung Kim
Chemosensors 2024, 12(5), 77; https://doi.org/10.3390/chemosensors12050077 - 7 May 2024
Abstract
Graphene-based chemical sensors hold promise across diverse applications owing to their exceptional sensitivity and selectivity. However, achieving their long-term durability and reusability while preserving high sensitivity remains a significant challenge, particularly in harsh environments where exposure to strong chemicals is inevitable. This paper
[...] Read more.
Graphene-based chemical sensors hold promise across diverse applications owing to their exceptional sensitivity and selectivity. However, achieving their long-term durability and reusability while preserving high sensitivity remains a significant challenge, particularly in harsh environments where exposure to strong chemicals is inevitable. This paper presents a novel approach to address this challenge by synergistically integrating liquid-phase exfoliated graphene (LPEG) with polytetrafluoroethylene (PTFE) within a single sensing strip. Through a comprehensive experimental investigation, we demonstrate the fabrication of highly durable and reusable chemical leak detection sensors by combining LPEG and PTFE. Furthermore, we explore the sensing mechanism, highlighting the roles of LPEG and PTFE in enhancing sensitivity and selectivity, along with durability and reusability. Performance evaluation reveals the sensors’ robustness against mechanical and chemical degradation, coupled with excellent recyclability. This innovative approach holds promise for applications in environmental monitoring, industrial safety, and healthcare, thus advancing the field of graphene-based chemical leak detection sensors.
Full article
(This article belongs to the Special Issue Novel Materials for Sensing, Imaging and Energy Conversion/Storage)
►▼
Show Figures
Figure 1
Open AccessArticle
Influence of Silsesquioxane-Containing Ultra-Thin Polymer Films on Metal Oxide Gas Sensor Performance for the Tunable Detection of Biomarkers
by
Oleg Lupan, Mihai Brinza, Julia Piehl, Nicolai Ababii, Nicolae Magariu, Lukas Zimoch, Thomas Strunskus, Thierry Pauporte, Rainer Adelung, Franz Faupel and Stefan Schröder
Chemosensors 2024, 12(5), 76; https://doi.org/10.3390/chemosensors12050076 - 5 May 2024
Abstract
Certain biomarkers in exhaled breath are indicators of diseases in the human body. The non-invasive detection of such biomarkers in human breath increases the demand for simple and cost-effective gas sensors to replace state-of-the-art gas chromatography (GC) machines. The use of metal oxide
[...] Read more.
Certain biomarkers in exhaled breath are indicators of diseases in the human body. The non-invasive detection of such biomarkers in human breath increases the demand for simple and cost-effective gas sensors to replace state-of-the-art gas chromatography (GC) machines. The use of metal oxide (MOX) gas sensors based on thin-film structures solves the current limitations of breath detectors. However, the response at high humidity levels, i.e., in the case of exhaled human breath, significantly decreases the sensitivity of MOX sensors, making it difficult to detect small traces of biomarkers. We have introduced, in previous work, the concept of a hybrid gas sensor, in which thin-film-based MOX gas sensors are combined with an ultra-thin (20–30 nm) polymer top layer deposited by solvent-free initiated chemical vapor deposition (iCVD). The hydrophobic top layer enables sensor measurement in high-humidity conditions as well as the precise tuning of selectivity and sensitivity. In this paper, we present a way to increase the hydrogen (H2) sensitivity of hybrid sensors through chemical modification of the polymer top layer. A poly(1,3,5,7-tetramethyl-tetravinylcyclotetrasiloxane) (PV4D4) thin film, already applied in one of our previous studies, is transformed into a silsesquioxane-containing top layer by a simple heating step. The transformation results in a significant increase in the gas response for H2 ~709% at an operating temperature of 350 °C, which we investigate based on the underlying sensing mechanism. These results reveal new pathways in the biomedical application field for the analysis of exhaled breath, where H2 indicates gastrointestinal diseases.
Full article
(This article belongs to the Special Issue Innovative Nanomaterials-Based Chemosensor Devices for Air Quality Monitoring)
►▼
Show Figures
Graphical abstract
Open AccessArticle
A Foldable Thermoplastic Microdevice Integrating Isothermal Amplification and Schiff-Reaction-Based Colorimetric Assay for the Detection of Infectious Pathogens
by
Hee Mang Kim and Nae Yoon Lee
Chemosensors 2024, 12(5), 75; https://doi.org/10.3390/chemosensors12050075 - 3 May 2024
Abstract
In this study, we introduce a plastic-based foldable microdevice that integrates loop-mediated isothermal amplification (LAMP) and a colorimetric assay based on the Schiff reaction to detect the genes of infectious bacteria. The device comprises two sides: a sample zone containing amplification chambers and
[...] Read more.
In this study, we introduce a plastic-based foldable microdevice that integrates loop-mediated isothermal amplification (LAMP) and a colorimetric assay based on the Schiff reaction to detect the genes of infectious bacteria. The device comprises two sides: a sample zone containing amplification chambers and a detection zone for the colorimetric assay. The detection zone contains poly(methyl methacrylate) structures for transferring the colorimetric reagent-soaked glass micro-fiber paper into the sample chambers. Specific genes of Staphylococcus aureus (S. aureus) and Streptococcus pneumoniae (S. pneumoniae), the most common bacterial infection causes, were amplified by LAMP assay. The S. aureus gene was detected up to 10 fg/μL and the S. pneumoniae gene up to 0.1 pg/μL. The amplified target genes were visually identified using a colorimetric assay with Schiff’s reagent, which showed clear color discrimination through a reaction with aldehyde groups derived from the DNA in the amplicons. The introduced method, integrating amplification and detection processes in a single device, is expected to be utilized in point-of-care testing analysis for the simple and rapid detection of infectious pathogens.
Full article
(This article belongs to the Section (Bio)chemical Sensing)
►▼
Show Figures
Figure 1
Open AccessArticle
A High-Precision Monitoring Method Based on SVM Regression for Multivariate Quantitative Analysis of PID Response to VOC Signals
by
Xiujuan Feng, Zengyuan Liu, Yongjun Ren and Chengliang Dong
Chemosensors 2024, 12(5), 74; https://doi.org/10.3390/chemosensors12050074 - 3 May 2024
Abstract
In the moist environment of soil-water-air, there is a problem of low accuracy in monitoring volatile organic compounds (VOCs) using a photoionization detector (PID). This study is based on the PID water-soil-gas VOC online monitor developed by this group, online monitoring of the
[...] Read more.
In the moist environment of soil-water-air, there is a problem of low accuracy in monitoring volatile organic compounds (VOCs) using a photoionization detector (PID). This study is based on the PID water-soil-gas VOC online monitor developed by this group, online monitoring of the concentration of different constituents of VOCs in different production enterprises of the petroleum and chemical industries in Shandong Province, with the concentration of the laboratory test, to build a relevant model. The correlation coefficient about the PID test concentration and the actual concentration correlation coefficient was obtained through the collection of a large number of data trainings. Based on the application of PID in VOC monitoring, the establishment of a PID high-precision calibration model is important for the precise monitoring of VOCs. In this paper, multiple quantitative analyses were conducted, based on SVM regression of PID response to VOC signals, to study the high-precision VOC monitoring method. To select the response signals of PID under different concentrations of environmental VOCs measured by the research group, first, the PID response to VOC signals was modeled using the support vector machine principle to verify the effect of traditional SVM regression. For the problem of raw data redundancy, calculate the time-domain and frequency-domain characteristics of the PID signal, and conduct the principal component analysis of the time-domain of the PID signal. In order to make the SVM regression more generalized and robust, the selection of kernel function parameters and penalty factor of SVM is optimized by genetic algorithm. By comparing the accuracy of PID calibration models such as PID signal feature extraction, SVM regression, and principal component analysis SVM regression, the superiority of photoionization detector using the signal feature extraction PCA-GA-SVM method to monitor VOCs is verified.
Full article
(This article belongs to the Special Issue Chemical Sensors for Volatile Organic Compound Detection, 2nd Edition)
►▼
Show Figures
Figure 1
Open AccessArticle
Biosensor-Based Assessment of Pesticides and Mineral Fertilizers’ Influence on Ecotoxicological Parameters of Soils under Soya, Sunflower and Wheat
by
Ludmila Khmelevtsova, Maria Klimova, Shorena Karchava, Tatiana Azhogina, Elena Polienko, Alla Litsevich, Elena Chernyshenko, Margarita Khammami, Ivan Sazykin and Marina Sazykina
Chemosensors 2024, 12(5), 73; https://doi.org/10.3390/chemosensors12050073 - 2 May 2024
Abstract
Pesticides and fertilizers used in agriculture can negatively affect the soil, increasing its toxicity. In this work, a battery of whole-cell bacterial lux-biosensors based on the E. coli MG1655 strain with various inducible promoters, as well as the natural luminous Vibrio aquamarinus VKPM
[...] Read more.
Pesticides and fertilizers used in agriculture can negatively affect the soil, increasing its toxicity. In this work, a battery of whole-cell bacterial lux-biosensors based on the E. coli MG1655 strain with various inducible promoters, as well as the natural luminous Vibrio aquamarinus VKPM B-11245 strain, were used to assess the effects of agrochemical soil treatments. The advantages of using biosensors are sensitivity, specificity, low cost of analysis, and the ability to assess the total effect of toxicants on a living cell and the type of their toxic effect. Using the V. aquamarinus VKPM B-11245 strain, the synergistic effect of combined soil treatment with pesticides and mineral fertilizers was shown, which led to an increase in the overall (integral) toxicity of soils higher than that of the individual application of substances. Several probable implementation mechanisms of agrochemical toxic effects have been discovered. DNA damage caused by both SOS response induction and alkylation, oxidative stress due to increased superoxide levels, and damage to cellular proteins and membranes are among them. Thus, the usage of biosensors makes it possible to assess the cumulative effect of various toxicants on living organisms without using expensive chemical analyses.
Full article
(This article belongs to the Special Issue Chemiluminescent and Bioluminescent Sensors)
►▼
Show Figures
Figure 1
Journal Menu
► ▼ Journal Menu-
- Chemosensors Home
- Aims & Scope
- Editorial Board
- Reviewer Board
- Topical Advisory Panel
- Instructions for Authors
- Special Issues
- Topics
- Sections & Collections
- Article Processing Charge
- Indexing & Archiving
- Editor’s Choice Articles
- Most Cited & Viewed
- Journal Statistics
- Journal History
- Journal Awards
- Conferences
- Editorial Office
Journal Browser
► ▼ Journal BrowserHighly Accessed Articles
Latest Books
E-Mail Alert
News
Topics
Topic in
Beverages, Fermentation, Foods, Molecules, Separations, Chemosensors
Advances in Analysis of Flavors and Fragrances: Chemistry, Properties and Applications in Food Quality Improvement
Topic Editors: Ana Leahu, Marìa Soledad Prats Moya, Cristina GhineaDeadline: 31 May 2024
Topic in
Analytica, Molecules, Nanomaterials, Polymers, Separations, Chemosensors
Nanomaterials in Green Analytical Chemistry
Topic Editors: George Zachariadis, Rosa Peñalver, Natalia ManousiDeadline: 15 August 2024
Topic in
Analytica, Metabolites, Toxins, Molecules, Cells, Chemosensors
Application of Analytical Technology in Metabolomics
Topic Editors: Preeti Chandra, Ugo Bussy, Raúl G. EnríquezDeadline: 31 October 2024
Topic in
Analytica, Foods, Molecules, Sensors, Separations, Chemosensors
Application of Liquid Chromatography-Mass Spectrometry and Related Techniques
Topic Editors: Chao Kang, Ronald BeckettDeadline: 15 December 2024
Conferences
Special Issues
Special Issue in
Chemosensors
Current Development on Electrochemical Glucose Biosensors
Guest Editors: Won-Yong Jeon, Young-bong ChoiDeadline: 31 May 2024
Special Issue in
Chemosensors
Nanomaterials-Based Sensors
Guest Editors: Simas Rackauskas, Agne SulciuteDeadline: 30 June 2024
Special Issue in
Chemosensors
Preparation and Application of Photoelectrochemical Sensors
Guest Editors: Mei Yan, Jing ZhangDeadline: 20 July 2024
Special Issue in
Chemosensors
Dedicated to Professor Giorgio Sberveglieri on the Occasion of His 75th Birthday for His Outstanding Contributions to the Field of Chemical Sensors
Guest Editors: Estefanía Núñez Carmona, Veronica SberveglieriDeadline: 30 July 2024
Topical Collections
Topical Collection in
Chemosensors
Women Special Issue in Chemosensors and Analytical Chemistry
Collection Editors: Teresa Corrales, Nicole Jaffrezic-Renault, Eleonora Alfinito
Topical Collection in
Chemosensors
Recent Trend in Chromatography for Pharmaceutical Analysis
Collection Editors: Cláudia Maria Rosa Ribeiro, Maria Elizabeth Tiritan
Topical Collection in
Chemosensors
Optical Chemosensors and Biosensors
Collection Editor: Ambra Giannetti
Topical Collection in
Chemosensors
Sustainable Metal Oxide Materials for Sensing Applications
Collection Editors: Ana Rovisco, Elisabetta Comini