Summary
Reversed-phase stationary phases based on porous silica beads in the range 0.2–3 μm have been prepared to study the dependency of electroosmotic flow (EOF) on particle diameter. Additionally, the influence of the mobile phase composition, i.e. organic modifier content, pH of buffer solution and concentration of buffer salt, on the magnitude of the electroosmotic flow velocity has been investigated. To perform separations in an aqueous acidic mobile-phase, mixed mode stationary phases containing both alkyl chains and strong cationexchange groups have been applied.
Similar content being viewed by others
References
M. Dittmann, G. Rozing, K. Wienand, F. Beck, LC GC13, No. 10, 800 (1995).
M. Dittmann, G. Rozing, G. Ross, Th. Adam, K. K. Unger, J. Capillary Electrophoresis5, 201 (1997).
H. Engelhardt, S. Lamotte, F. T. Hafner, American Laboratory30, 40 (1998).
B. Behnke, E. Grom, E. Bayer, J. Chromatogr.716, 207 (1995).
J. H. Knox, I. H. Grant, Chromatographia32, 317 (1991).
R. M. Seifar, W. T. Kok, J. C. Kraak, H. Poppe, Chromatographia46, 131 (1997).
R. Dadoo, C. Yan, R. Zare, LC GC15, 630 (1997).
L. Colon, A. M. Fermier, J. Microcolumn Separation10, 439 (1998).
M. Dittmann, G. Rozing, J. Microcolumn Separation9, 399 (1997).
N. W. Smith, K. D. Altria, C. H. Turnbull, Chromatographia46, 664 (1997).
W. Stöber, A. Fink, E. Bohn, J. Colloid Interface Sci.26, 62 (1968).
C. Kaiser, K. K. Unger, Patent Application No. P19530031.J.
K. Lork, J. Kinkel, K. K. Unger, J. Chromatogr.325, 199 (1986).
S. Lüdtke, Th. Adam, K. K. Unger, J. Chromatogr.768, 229 (1997).
J. H. Knox, I. H. Grant, Chromatographia24, 135 (1987).
G. Choudhary, C. Horvath, J. Chromatogr.781, 161 (1997).
A. S. Rathore, C. Horvath, J. Chromatogr.781, 185 (1997).
C. Schwer, E. Kenndler, Anal. Chem.63, 1801 (1991).
J. G. Dorsey, A. S. Lister, P. B. Wright, Analytical Chemistry69, 3251 (1997).
Q. H. Wan, J. Chromatogr.782, 181 (1997).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Adam, T., Lüdtke, S. & Unger, K.K. Packing and stationary phase design for capillary electroendosmotic chromatography (CEC). Chromatographia 49 (Suppl 1), S49–S55 (1999). https://doi.org/10.1007/BF02468976
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02468976