Abstract
Three methods of atropine and scopolamine determination in transdermal permeation have been developed. Radiometric determination seems to be an excellent, quick and extremely sensitive method, which ought to be preferred when working with biological systems. The radioreceptor analysis is of group specificity. It can be used to advantage in monitoring atropine plasma concentrations exceeding 1.5 ng cm−3 and scopolamine concentrations above 50 pg cm−3. GC/MS provides adequate specificity and sensitivity for the determination of therapeutic levels of atropine and scopolamine in blood. The sensitivity of this method is approximately 1–2 ng cm−3.
Similar content being viewed by others
References
Y. Horimoto, M. Naide,Canad. J. Anaesth., 37 (1990) 94.
P. Semple, T. H. Madej, R. G. Wheatley, I. J. Jackson, J. Stevens,Anaesthesia, 47 (1992) 399.
J. How, P. Lee, L. C. Seet, P. K. Tan,Aviat. Space Environ. Med., 59 (1988) 646.
L. Brown, R. Langer,Ann. Rew. Med., 39 (1988) 221.
C. T. Richardson, M. Feldman,Gut, 27 (1986) 1493.
R. H. Guy, J. Hadgraft,J. Control. Rel., 1 (1985) 177.
R. H. Guy, J. Hadgraft, D. A. Bucks,Xenobiotica, 17 (1987) 325.
P. H. Hinderling, U. Gundert-Remy, O. Schmidlin,J. Pharm. Sci., 74 (1985) 703.
P. H. Hinderling, U. Gundert-Remy, O. Schmidlin,J. Pharm. Sci., 74 (1985) 711.
V. Koprda, et al.: Study of Auxiliary Pharmaceutical Substances, New Forms of Drugs and Transdermal Therapeutic Systems (Report, In Slovak), Bratislava, UEF SAV, 1990.
R. J. Lefkowitz, J. Roth, I. Tastan,Science, 170 (1970) 633.
J. Šmisterová,Farm. Obz., 61 (1992) 193.
K. Ensing, R. A. De Zeeuw,Pharm. Res., 3 (1986) 327.
D. H. Lowry, N. J. Rosenbough, A. L. Ferr, R. J. Randall,J. Biol. Chem., 193 (1951) 265.
R. Wunderwald, G. Jurz, G. Michal,Anal. Biochem., 59 (1974) 468.
K. Ensing, K. G. Feitoma, W. G. Bloemhof, R. A. De Zeeuw,J. Biomed. Biophys. Meth., 13 (1986) 85.
R. F. Metcalfe,Biochem. Pharmacol., 130 (1980) 209.
L. Stoll, P. Flackenstein, D. Riemen, W. E. Muller,Res. Com. Chem. Pathol. Pharmacol., 64 (1989) 59.
W. F. Bayne, F. T. Tao, N. Crisologo,J. Pharm. Sci., 64 (1975) 288.
M. Eckert, P. H. Hinderling,Agents Actions, 11 (1981) 520.
J. Saady, A. Poklis,J. Anal. Toxicol., 13 (1989) 296.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Koprda, V., Bohov, P., Smisterová, J. et al. Methods of assessment of atropine and scopolamine levels in transdermal permeation. Journal of Radioanalytical and Nuclear Chemistry Letters 188, 439–451 (1994). https://doi.org/10.1007/BF02164737
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02164737