ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Organochlorine pesticides  (2)
Collection
Keywords
Publisher
Years
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 15 (1992), S. 319-328 
    ISSN: 0935-6304
    Keywords: Organochlorine pesticides ; Fused silica open tubular column ; Dual-column, dual-detector gas chromatographic system ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Forty five organochlorine pesticides (currently listed in EPA Method 8081A) have been chromatographed on DB-5/DB-1701 and SPB-5/SPB-1701 column pairs which were in each case connected to an inlet splitter and separate electron capture detectors. Thirteen additional compounds were evaluated for their suitability as internal standards or surrogate compounds for incorporation into Method 8081A. Method reproducibility and linearity are discussed, and results are presented for extracts of six real samples spiked with fifteen organochlorine pesticides and analyzed using the dual-column, dual-detector arrangement.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 247-256 
    ISSN: 0935-6304
    Keywords: Gas chromatography with electron capture detection ; Solid phase microextraction ; Organochlorine pesticides ; Water analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes the extraction of 20 organochlorine pesticides (OCPs) from water samples using solid-phase microextraction (SPME). Three fused-silica fibers coated or bonded with polydimethylsiloxane (PDMS) of different film thicknesses (20-, 30-, and 100-μm) were evaluated. The extraction time, the effects of stirring and addition of NaCl to the aqueous sample, the linear range and the precision of this technique, and the effect of carryover were examined for 20 analytes and are presented here. A comparison with results using conventional liquid-liquid extraction demonstrate that the SPME technique is well suited as a fast screening technique for OCPs in water samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...