ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Ni3Al  (1)
  • Root canal length  (1)
  • Springer  (2)
Sammlung
Verlag/Herausgeber
  • Springer  (2)
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Oxidation of metals 46 (1996), S. 51-72 
    ISSN: 1573-4889
    Schlagwort(e): Ni3Al ; θ-Al2O3 ; α-Al2O3 ; oxidation mechanism
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau
    Notizen: Abstract The high-temperature oxidation behaviour of pure Ni3Al alloys in air was studied above 1000°C. In isothermal oxidation tests between 1000 and 1200°C, Ni3Al showed parabolic oxidation behavior and displayed excellent oxidation resistance. In cyclic oxidation tests between 1000 and 1300°C, Ni3Al exhibited excellent oxidation resistance between 1000 and 1200°C, but drastic spalling of oxide scales was observed at 1300°C. When Ni3Al was oxidized at 1000°C, Al2O3 was present as θ-Al2O3 in a whisker form. But, at 1100°C the gradual transformation of initially formed metastable θ-Al2O3 to stable α-Al2O3 was observed after oxidation for about 20 hr. After oxidation at 1200°C for long times, the formation of a thick columnar-grain layer of α-Al2O3 was observed beneath a thin and fine-grain outer layer of α-Al3O3. The oxidation mechanism of pure Ni3Al is described.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 40 (1992), S. 200-204 
    ISSN: 1741-0444
    Schlagwort(e): Tooth ; Root canal length ; Voltage difference ; Endodontic therapy ; Impedance ratio ; Clinical evaluation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Electronic root canal length measurement devices have made it easier and faster to measure the root canal length of a tooth compared with the conventional radiographic method. Of these electronic apex locators, the frequency-dependent type features greater accuracy and convenience in operation. However, its accuracy is still influenced by the presence of blood and/or the various electrolytes used in root canal therapy. This study describes the development of a new frequency-dependent electronic apex locator featuring electrolyte compensation, utilising an impedance ratio and voltage difference technique to minimise the influence of electrolytes on the accuracy of root canal length measurement. The errors for distances from file tips to apical constrictions were determined in vivo with the device operating with electrolyte compensation. The measured lengths were compared with the true lengths of the extracted teeth determined using a microscope. The mean error was +0.14±0.27 mm, and 95.2% of the measurements were within the clinical tolerance of ±0.5 mm. It was also found that the degree of accuracy was not dependent on the size of the apical foramen (p=0.74).
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...